Cleaning method 

MAINTENANCE

Do not use the detergents shown below.

For installation and removal methods of front 

panel and filters, please read P.7~8. 

When cleaning, do not leave the removed parts 

unattended. 

(Otherwise, it may cause tripping or damage.)

Do not operate the product when the HEPA 

composite filter is removed. 

(Dust will be inhaled into product inner parts, 

and causes the product breakdown. The HEPA

composite filter cannot function while it is

removed.) 

Do not operate the product when the deodoriz-

ing filter is removed. 

(The deodorizing filter cannot function while it 

is removed.)

When using chemically treated cloth, be sure 

to follow the instructions carefully.

Make sure to disconnect the 

power plug before cleaning

the product.

(Otherwise, the product might operate 

with the possibility of electric shock or 

injury.)

WARNING

Polish

Alkaline detergent

Thinner

Bleach

Kerosene

Alcohol

MAINT

ENANCE

11

Deodorizing filter

When there is dust around the deodorizing

filter, remove the dust with a vacuum 

cleaner, etc.

Do not wash the filter with water.

Clean the black side (front side) 

with a vacuum cleaner, etc.

HEPA composite filter

< about once every 2 weeks >

Dusting brush nozzle 

or gap suction nozzle

Do not wash the 

filter with water.

Please do not punch too much, otherwise

the filter may be damaged. 
Maintenance is unnecessary for the white 

side (back side).

Wipe off any dust and dirt using 

a well wrung-out cloth

Body and front panel

< about once a month >

Do not wipe it with a hard cloth or hardly.

Otherwise, the surface may be damaged.

Wipe the power plug with a dry cloth.

Lens(top left)

Dry cotton swab

Wipe the dirt off the lens with a dry

cotton swab

Dirt sensor

< about once every 3 months >

Remove the external cover of dirt sensor as

shown below.
Wipe the lens with a dry cotton swab as 

shown below.

Wipe the lens periodically. 

(The sensor may not function normally with 

accumulation of moisture and smoke from 

cigarette.)

Lay with newspapers, etc 

to avoid dust messing floor. 

Notice

Do not insert a cotton swab in other parts 

other than the lens.
Be sure to disconnect the power plug before 

cleaning.
You can use a light to see the lens clearly.

Summary of Contents for F-PXV55M

Page 1: ... damage Make sure that the correct information is written on the warranty card including the date of purchase and the name of the distributor Keep the warranty card in a safe place along with the operating instructions for future reference Warranty card attached Air Purifier Model No This product is for indoor use only OPERATING INSTRUCTIONS CONTENTS OPERATION BACK COVER OPERATION MAIN PARTS IDENT...

Page 2: ...structed The following symbols are used to indicate the type of instructions that need to be followed The symbols given below are examples Do not pull the power cord when carrying or storing the product Otherwise the power cord may be damaged with the possibility of fire or electric shock Do not damage the power cord or power plug Do not cut modify excessive distort twist squeeze the power cord an...

Page 3: ...er socket CAUTION Do not place the product in the following places Incline and unstable place Otherwise the product may fall over and injury may occur or damage the product Where the temperature or humidity is extremely high or watery area such as bathroom Otherwise current may leak with the possibility of fire or electric shock Where oil fume is emitted such as in kitchens Otherwise the product m...

Page 4: ...t in places where indoor fumigation type insecticides are being used Chemical residue may build up inside the product and discharge from the air outlet and cause damage to health Ventilate the room with fresh air thor oughly after using insecticides before operating the product Do not set the product in the following places Where the product will be exposed directly to sunlight outlet air of air c...

Page 5: ...high moisture content small particles high stability etc 1 High moisture content the moisture content is 1 000 times the moisture content of ordinary anions 2 Small particles about 5 nm 20 nm nanometers in size able to penetrate deep into the fiber and stratum corneum 3 High stability 6 times more stable than a common ion covering a distance of 10 m or above All of the above features have been tes...

Page 6: ...justed P 13 Clean sign Blue indicates clean Red small indicates slight dirty Red large indicates dirty Show the air pollution levels detected by dirt sensor and odor sensor The clean sign can be turned off P 14 The indicator lights on indicates you need to replace HEPA composite filter P 12 The indicator lights on indicates nanoeTM X is being generated nanoeTM X will be generated in all operation ...

Page 7: ...se don t remove the black net of deodorizing filter Poly bag Deodorizing filter wrap in black net Front panel Pull it forward with both hands Pull it forward with both hands Fill in the label with the first date of use Remove the deodorizing filter from the poly bag HEPA composite filter Make sure to read page 2 4 before setting up the product CONFIRMATION AND SETUP 7 Notice ...

Page 8: ...l Fit the clutch into the indentation 2 places of product 4 When inserting the power plug as the odor sensor uses the degree of cleanliness at this time as the standard we recommend that you plug it in when the air is fresh when there is no cigarette smoke The standard of the odor sensor automatically updates itself according to the degree of the indoor cleanliness Push in the protrusion into the ...

Page 9: ... operate The product operates in auto air volume mode when it is used for the first time then operates in the last mode when it was stopped Power Off On Indicator lights on Purify air quickly Purify air in medium speed Purify air quietly in low speed Select appropriate air volume for purifying air The indicator will be changed sequentially as figure below Automatically adjust the air volume accord...

Page 10: ...lights off The indicator will be changed sequentially as figure below Timer operation Timer 2 hours timer The product will stop operating after 2 hours 4 hours timer The product will stop operating after 4 hours Cancel timer 8 hours timer sleep mode Clean sign and air volume indicator light off indicators on control panel dim and the product operates at low speed then stops operating after 8 hours...

Page 11: ...lter remove the dust with a vacuum cleaner etc Do not wash the filter with water Clean the black side front side with a vacuum cleaner etc HEPA composite filter about once every 2 weeks Dusting brush nozzle or gap suction nozzle Do not wash the filter with water Please do not punch too much otherwise the filter may be damaged Maintenance is unnecessary for the white side back side Wipe off any dus...

Page 12: ...r the old date P 7 Filter replacement period may be shorten depending on the environ ment such as where smoking is frequent Please replace it when ineffective When idle for a long time Disconnect power after turning off the product The product still consumes power even at rest Maintain the product as usual Put the product into poly bag and carton and keep it in a dry place If you overturn it or ke...

Page 13: ... the generation time of dirt every day Automatically stops operating when the clean air is detected meanwhile it also operates in advance to eliminate the dirt effectively before spreading thus reducing the operation time and saving power The product will stop operating automatically after the air is cleaned After the operation is paused for 50 min the product will operate for 10 min with air volu...

Page 14: ...set to Hi Med or Lo the air volume cannot adjust automatically Detects the indoor brightness by the light sensor and automatically adjusts the brightness of indicators and the air volume When sleeping the room becomes dark the indicators will be dimmed or light off and the air volume becomes low Light low level Light low level No change Light low level No change No change No change No change Contr...

Page 15: ...act the dealer for repair If any of the following cases occur please contact the dealer immediately for repair All the air volume indicators are blinking There is sound Has the product ever been used in a room with strong odor If the product is used in a room with strong odor such as aromatic smell cigarette smoke or barbecue smell the filter replacement period may be shortened If you use the prod...

Page 16: ...d length Product dimension Product weight Air volume settings Air volume m3 min Power consumption W 1 Floor area capacity 2 Note This product cannot remove hazardous substances such as carbon monoxide from the cigarette smoke The power consumption is about 0 3 W when the operation is set to Off With the power plug inserted OPTIONAL ACCESSORIES All the air volume indicators are blinking For additio...

Reviews: