- 14 -
EN
EN
EN
EN
4. Press the OK button to accept the new
setting.
NOTE:
• When the remaining number of tighten-
ing operations is 10,000 or less, the
display will alternate between “Setting”
and “1.” When the remaining number
of tightening operations reaches 0, the
value “0” will flash on the display.
To reset the count to 0, initialize the tool
(see page 15).
• The maximum tightening operation
count value is 990,000. Operations in
excess of 990,000 will not be counted.
Radio signal range limitation function
on/off setting (EYFGA1AR, EYFGA2AR,
EYFGA3AR)
1. Set the tool to setting configuration mode.
(See page 1.)
. Press the C button three times.
• Radio signal range limitation function
on/off setting value will be displayed.
See the illustration
16
3. Press the or buttons to set radio sig-
nal range limitation function on/off.
Display
Radio signal
range limitation
function mode
Status
C0
OFF
Tool is operational in the
absence of communica-
tions with the Assembly
Qualifier.
C1
ON
Tool is not operational
in the absence of com-
munications with the As-
sembly Qualifier.
4. Press the OK button to accept the new
setting.
NOTE:
• For more information about how to register
the tool and Assembly Qualifier, see the
Assembly Qualifier instruction manual.
Buzzer setting
• You can select from three buzzer modes.
1. Set the tool to setting configuration mode.
(See page 1.)
. Press the A button once.
• The current setting value will be dis-
played.
3. Press the or buttons to set the
desired value.
Display
Function
b0
No buzzer
b1
Buzzer accompanying green indicator
b
Buzzer accompanying red indicator
4. Press the OK button to accept the new
setting.
LED light setting
• You can select from two LED light modes.
1. Set the tool to setting configuration mode.
(See page 1.)
. Press the B button once.
• The current setting value will be dis-
played.
3. Press the or buttons to set the
desired LED mode.
Display
Function
L1
Linked to LED light button
L
Linked to trigger switch operation
4. Press the OK button to accept the new
setting.
Speed control function
• The speed (RPM) can be changed with the
amount of depression of the trigger.
1. Set the tool to setting configuration mode.
(See page 1.)
. Press the B button three times.
• The setting value will be displayed.
3. Press the or buttons to change the
setting to ON or OFF.
Operation
Function
P0
Speed control ON
P1
Speed control OFF
4. Press the OK button to accept the new set-
ting.