Cautions

WARNING

 

Never use this product as a sensing device for personnel protection.

 

When using sensing devices for personnel protection, use products that meet laws 
and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in 
each region or country.

 

This product has been developed / produced for industrial use only.

 

 This product employs a small cable of 0.1mm

2

 in conductor area. Take care that the 

cable is not pulled with a strong force, as it may damage this product or break its wires.

 

 Make sure that stress by forcible bend or pulling is not applied to the sensor cable joint.

 

 

Cable can be extended up to 50m in total length (each emitter / receiver of thru-beam 
type) if extension cable is more than 0.3mm

2

 in electric conductor cross-sectional area.

 

 Make sure that the power supply is OFF while adding or removing the controllers.

 

Take note that incorrect wiring will damage the sensor.

 

Verify that the supply voltage variation is within the rating.

 

If power is supplied from a commercial switching regulator, ensure that the frame ground 
(F.G.) terminal of the power supply is connected to an actual ground.

 

When noise generating equipment (switching regulator, inverter motor, etc.) is used in 
the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to 
an actual ground.

 

 Do not run the wires together with high-voltage lines or power lines or put them in the 
same raceway. This can cause malfunction due to induction.

 

● Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter 

lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing per-
formance.

 

 Do not use during the initial transient time (50ms) after the power supply is switched 
ON.

 

This product is suitable for indoor use only.

 

Avoid dust, dirt, and steam.

 

Do not use this sensor in places where it may come in contact with corrosive gas, etc.

 

Ensure that the product does not come into contact with organic solvents such as thin-
ner.

 

Ensure that the product does not come into contact with strong acid or alkaline.

 

Ensure that the product does not come into contact with oil or grease.

 

 This product cannot be used in an environment containing inflammable or explosive 
gases.

 

Never disassemble or modify the product.

 

Cable end has not been waterproofed. Do not use the product in any manner that may 
cause water entry via cable end.

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Summary of Contents for EX-Z Series

Page 1: ...Ultra minute Photoelectric Sensor EX Z Series USER S MANUAL WUME EXZ 1 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 2: ...lation interval 7 4 I O Circuit Diagram 9 5 Stability Indicator 10 6 Beam Alignment 11 7 Option 12 7 1 Sensor mounting bracket 12 8 Specifications 13 8 1 Side sensing type 13 8 2 Front sensing type 14 9 Dimensions 15 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 3: ...d When noise generating equipment switching regulator inverter motor etc is used in the vicinity of this product connect the frame ground F G terminal of the equipment to an actual ground Do not run the wires together with high voltage lines or power lines or put them in the same raceway This can cause malfunction due to induction Take care that the sensor is not directly exposed to fluorescent la...

Page 4: ...hts up under the stable light condition or the stable dark condition Thru beam emitter front sensing type EX Z11F EX Z12F EX Z13F Beam emitting part Thru beam receiver front sensing type EX Z11F EX Z12F EX Z13F Operation indicator Orange Lights up when the sensing output is ON Beam receiving part Stability indicator Green Lights up under the stable light condition or the stable dark condition Phon...

Page 5: ...nsing type Sensing direction 8 5 M2 screw length 6 accessory M2 0 4 Tapping depth 7 When using screws and nuts that are accessory of the product Unit mm Side sensing type Sensing direction 8 5 M2 screw length 10 accessory Thickness of mounting plate 2 or less Nut Spring washer Flat washer Thickness of mounting plate 2 or less Nut Spring washer Flat washer Front sensing type Sensing direction 8 5 M...

Page 6: ...aped mounting bracket MS EXZ 1 Mounting bracket for front sensing type MS EXZ 2 Mounting spacer for front sensing type MS EXZ 4 Mounting bracket for side sensing type MS EXZ 3 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 7: ...ensors by 2 X ℓ1 or more EX Z11 EX Z11F Parallel deviation diagram typical 80 40 60 0 20 0 10 10 20 20 Operation distance ℓ mm Center Left Right L1 ℓ1 Sensing distance L mm In case using at sensing distance L1 50mm the operation point ℓ1 is approx 8 02mm according to diagram above The installation interval is Approx 8 02mm X 2 approx 16 04mm Thus install the product to approx 16 04mm or more away ...

Page 8: ...mm or more away Installation interval 200mm 61mm 61mm EX Z13 EX Z13F Parallel deviation diagram typical 800 400 600 0 200 0 50 50 100 100 Operation distance ℓ mm Center Left Right L3 ℓ3 Sensing distance L mm In case using at sensing distance L3 500mm the operation point ℓ3 is approx 81 9mm according to the diagram at left The installation interval is Approx 81 9mm X 2 approx 163 8mm Thus install t...

Page 9: ...circuit NPN output type Thru beam type receiver EX Z1 Main circuit Brown V Black Output Blue 0V Load 12 to 24V DC 10 Users circuit Internal circuit PNP output type Thru beam type receiver EX Z1 P Main circuit Brown V Black Output Blue 0V Load 12 to 24V DC 10 Users circuit Internal circuit Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 10: ...in both the Light state operation and the Dark state operation without being affected by changes in temperature voltage etc Approx 15 Approx 25 100 0 Lights up Turned off Light state operation Dark state operation Lights up Output operation level Light margin width Dark margin width Output operation Stability indicator operation Sensing distance 0 Incident light intensity Phone 800 894 0412 Fax 88...

Page 11: ...lp of the operation indicator orange and place it almost at the center 2 Similarly adjust for up down left and right angular move ment of the emitter 3 Further perform the angular adjustment for the receiver also 4 Check that the stability indicator green lights up Emitter Receiver Sensing object Operation indicator Orange Stability indicator green Phone 800 894 0412 Fax 888 723 4773 Web www clrwt...

Page 12: ...nsing type 2 sets required Material Stainless steel SUS304 M2 length 4mm screw 2 screws attached MS EXZ 3 Mounting bracket for side sensing type 2 sets required Material Stainless steel SUS304 M2 length 8mm screw 2 screws attached Spacer for mounting at the back MS EXZ 4 Mounting bracket for front sensing type 10 pieces set Material POM M2 length 10mm screw nut spring washer flat washer 20 pieces ...

Page 13: ... 85 RH Storage 35 to 85 RH Ambient illuminance Incandescent light 5 000ℓx at the light receiving face Voltage withstandability 1 000V AC for one min between all supply terminals connected together and enclosure Insulation resistance 20MΩ or more with 250V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500Hz frequency 3mm amplitude 20G max in X Y ...

Page 14: ...e 35 to 85 RH Ambient illuminance Incandescent light 5 000ℓx at the light receiving face Voltage withstandability 1 000V AC for one min between all supply terminals connected together and enclosure Insulation resistance 20MΩ or more with 250V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500Hz frequency 3mm amplitude 20G max in X Y and Z directi...

Page 15: ...ote The cable diameter of inflection resistant cable type is ø0 7mm Thru beam type front sensing type EX Z11F EX Z12F EX Z13F Unit mm 1 5 1 5 3 3 8 8 1 75 1 75 4 25 4 25 1 75 1 75 4 4 4 4 8 5 8 5 12 12 14 14 4 025 4 025 4 45 4 45 2 ø2 2 2 ø2 2 2 R1 8 2 R1 8 ø2 cable 2m Cable diameter ø0 6 Note 1 ø2 cable 2m Cable diameter ø0 6 Note 1 Emitter Receiver Note The cable diameter of inflection resistant...

Page 16: ... mounting bracket MS EXZ 2 Unit mm 1 2 3 3 9 18 7 15 8 3 2 1 4 8 5 12 3 5 6 25 6 8 3 2 1 75 1 4 4 M2 X 0 4 thru hole threads Sensor mounting bracket MS EXZ 3 Unit mm 1 4 1 2 3 2 7 5 17 7 12 7 25 8 5 8 15 3 2 1 4 6 8 9 9 3 5 2 M2 X 0 4 thru hole threads Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Page 17: ...17 Spacer for mounting at the back MS EXZ 4 Unit mm 5 1 8 5 12 4 5 2 8 3 5 1 7 2 ø2 2 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...

Reviews: