background image

857

Leak Detection Sensor 

EX-F70

 

SERIES 

 

EX-F60

 

SERIES

FIBER

SENSORS

LASER

SENSORS

PHOTO-

ELECTRIC

SENSORS

MICRO

PHOTO-

ELECTRIC

SENSORS

AREA

SENSORS

LIGHT

CURTAINS

PRESSURE / 

FLOW

SENSORS

INDUCTIVE

PROXIMITY

SENSORS

PARTICULAR

USE 

SENSORS

SENSOR

OPTIONS

SIMPLE

WIRE-SAVING

UNITS

WIRE-SAVING 

SYSTEMS

MEASURE-

MENT

SENSORS

STATIC 

CONTROL

DEVICES

ENDOSCOPE

LASER

MARKERS

PLC /

TERMINALS

HUMAN 

MACHINE 

INTERFACES

ENERGY 

CONSUMPTION 

VISUALIZATION 

COMPONENTS

FA 

COMPONENTS

MACHINE 

VISION 

SYSTEMS

UV 

CURING 

SYSTEMS

Selection 

Guide
Wafer 

Detection

Liquid Leak 

Detection

Liquid Level 

Detection

Water 

Detection

Color Mark 

Detection

Hot Melt Glue 

Detection

Ultrasonic

Small / Slim 

Object Detection

Obstacle 

Detection

Other 

Products

SQ4

EX-F70/

EX-F60

I/O CIRCUIT AND WIRING DIAGRAMS

EX-F7□  EX-F6□

NPN output type

I/O circuit diagram

Wiring diagram

EX-F7□

EX-F6□

Symbols … D  : Reverse supply polarity protection diode

Z

D

: Surge absorption zener diode

Tr : NPN output transistor

Users’ circuit 

Internal circuit 

50 mA  max. 

(Blue) 0 V 

(Brown) +V 

(Black) Output 

Color code 

12 to 24 V DC

±10 %

Tr 

Z


– 

Load 

Sensor circuit

 

 

Blue 

Brown 

Black 

12 to 24 V DC 

±10 %

Load 

– 

 

Blue 

Brown 

Black 

12 to 24 V DC 

±10 %

Load 

– 

EX-F7□-PN  EX-F6□-PN

PNP output type

I/O circuit diagram

Wiring diagram

EX-F7□-PN

EX-F6□-PN

I/O circuit diagram (for one channel)

Note:  The output does not incorporate a short-circuit protection circuit. 

Do not connect it directly to a power supply or a capacitive load.

* 1

Non-voltage contact or NPN open-collector transistor

(Amplifier built-in leak detection sensor)

or

Z

T


– 

Users’ circuit 

Internal circuit 

(Brown) +V 

(Black) Output 

(Blue) 0 V 

Color code 

50 mA  max. 

Load 

Sensor circuit

 

12 to 24 V DC

±10 %

Blue 

Brown 

Black 

12 to 24 V DC 

±10 %

Load 

– 

Blue 

Brown 

Black 

12 to 24 V DC

 

±10 %

Load 

– 

Main circuit

 

Internal circuit 

Terminal No. 

Color code 

(Brown) 12 to 24 V DC ±10 %

12 to 24 V DC ±10 %

(White) OUT 

 
(Black) OUT 

(Blue) 0 V 

Sensor side 

IN 

0 V 

Not  

connected 

Users’ circuit 

*1 

Relay contact (1a) 

Symbols … D  : Reverse supply polarity protection diode

Z

D

: Surge absorption zener diode

Tr : PNP output transistor

EX-FC1

Simple wire-saving unit for leak detection sensor

Summary of Contents for EX-F70 SERIES

Page 1: ...ly and a FAULT indicator red which lights up when sensing the leaked liquid or when mounted incorrectly forgetting to mount exclusive mounting bracket So the operation can be checked easily PVC mounti...

Page 2: ...m 16 404 ft cable length type of EX F71 PN is EX F71 PN C5 Simple wire saving unit for leak detection sensor Appearance Model No Output EX FC1 Relay contact 1 a 5 m 16 404 ft cable length type PFA en...

Page 3: ...0 V or less at 50 mA source current 0 4 V or less at 16 mA source current Utilization category DC 12 or DC 13 Output operation In normal state ON When leak detected or the sensor is mounted improperly...

Page 4: ...chanical lifetime 50 million switching operations or more switching frequency 180 operations min Utilization category DC 12 or DC 13 Output operation The output relay is ON when the input signal from...

Page 5: ...sistor Users circuit Internal circuit 50 mA max Blue 0 V Brown V Black Output Color code 12 to 24 V DC 10 Tr D ZD Load Sensor circuit Blue Brown Black 12 to 24 V DC 10 Load Blue Brown Black 12 to 24 V...

Page 6: ...thick the sensor body cannot be fitted to the mounting bracket How to fit the sensor body to the exclusive mounting bracket Match the notch in the sensor body with the projection of the exclusive moun...

Page 7: ...to each channel and the connection setting switch is set to ON Error indicator Red LED 8 Lights up when leak is detected by any sensor connected or any sensor is mounted improperly For details refer t...

Page 8: ...ke sure that the power supply is off while wiring Verify that the supply voltage variation is within the rating Take care that if a voltage exceeding the rated range or an AC power supply is directly...

Page 9: ...ing bracket for EX F72 PN MS EX F7 3 For two point fixing MS EX F7 2 For adhesive fixing Note A M4 stud bolt has been welded to this unit M4 nut is not supplied with the sensor Purchase it separately...

Page 10: ...6 26 1 024 2 5 0 098 cable 3 m 9 843 ft long NORMAL indicator Green FAULT indicator Red 19 0 748 9 0 354 3 0 188 14 0 551 19 0 748 FAULT indicator Red NORMAL indicator Green 2 4 2 0 165 4 5 0 177 17 0...