Thank you very much for purchasing Panasonic products. 
Please read this Instruction Manual carefully and thoroughly 
for the correct and optimum use of this product. Kindly keep 
this manual in a convenient place for quick reference.

This product is a sensor for detecting leak of 
fluids.
When this product is used with safety devices, 
construct the system such that the device itself 
always operates in the safety side.

ە

ە

WARNING

SPECIFICATIONS

1

Incandescent light: 1,000 lx or less at the light-receiving face

Ambient illuminance

Infrared LED (non-modulated)

Emitting element

Enclosure: PFA

Material

0.1mm

3-core PFA 

cabtyre cable, 3m long

0.1mm

3-core PFA 

cabtyre cable, 5m long

0.1mm

3-core PFA 

cabtyre cable, 3m long

0.1mm

3-core PFA 

cabtyre cable, 5m long

Cable

IP67(IEC)

Protection

-10 to +60

Υ

 (No dew condensation or icing allowed) (Note 3, 4), Storage: -20 to +70

Υ

Ambient temperature

35 to 85% RH, Storage: 5 to 85% RH

Ambient humidity

50ms or less

Response time

Red LED (lights up when leak is detected or the sensor is mounted improperly.)

Abnormality indicator

Green LED (lights up when the sensor is mounted properly.)

Normal indicator

ON when normal operation, OFF when leak is detected or the sensor is mounted improperly.

Output operation

Incorporated

Short-circuit protection



<NPN output type>
NPN open-collector transister

Maximum sink current: 50mA
Applied voltage: 30V DC or less (between output and 0V)
Residual voltage: 1.0V or less (at 50mA sink current)

0.4V or less (at 16mA sink current)

<PNP output type>
PNP open-collector transister



Maximum source current: 50mA
Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1.0V or less (at 50mA source current)

0.4V or less (at 16mA source current)

Output

Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note1, 2)

Sensing object 

12 to 24V DC 

s

 10%

Ripple P-P 10% or less

Supply voltage

15mA or less

Current consumption

Type

Model
No.

NPN output type

PNP output type

PFA mounting bracket type (For screw-fixing)

PVC mounting bracket type (For adhesive-fixing)

EX-F61

EX-F61-PN

3m cable length type

EX-F61-C5

EX-F61-PN-C5

5m cable length type

EX-F62

EX-F62-PN

3m cable length type

Item

EX-F62-C5

EX-F62-PN-C5

5m cable length type

60g approx.

80g approx.

60g approx.

80g approx.

Weight

PFA mounting bracket: 1 pc.

PVC mounting bracket: 1pc.

Accessories

Notes: 1)

2)

3)
4)

Highly viscous liquid may not be stably detected.
The agents mentioned above are examples. Further, PVC mounting bracket may not be used 
depending on type or viscosity etc. of the agent. For details, please contact us.
Liquid being detected should be also kept within the rated ambient temperature range.
The specified ambient temperature is only for fixed product.

CAUTIONS

2

ە
ە

ە
ە
ە

ە

ە

ە

ە

ە

ە

This product has been developed / produced for industrial use only.
Avoid using the product in an explosive atmosphere because this 
product does not have an explosive-proof protective construction.
Make sure to carry out the wiring in the power supply off condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if 
an AC power supply is directly connected, the sensor may get burnt 
or damaged.
If power is supplied from a commercial switching regulator, ensure that the 
frame ground (F.G.) terminal of the power supply is connected to an actual 
ground.
Do not use during the initial transient time (50m sec. approx.) 
after the power supply is switched on.
In case noise generating equipment (switching regulator, inverter 
motor, etc.) is used in the vicinity of this product, connect the frame 
ground (F.G.) terminal of the equipment to an actual ground.
Cable extension is possible up to total 50m with 0.3mm

2

, or more, cable. 

However, in order to reduce noise, make the wiring as short as possible.
Do not run the wires together with high-voltage lines or power lines or put 
them in the same race way. This can cause malfunction due to induction.
In case a surge is generated in the used power supply, connect a 
surge absoeber to the supply.

ە

ە

ە

ە

ە

ە

ە

ە

ە

Be sure to use the exclusive mounting bracket when installing the 
sensor to avoid human error, etc. Reliable detection cannot be 
guaranteed when this mounting bracket is not used.
Make sure to use an isolation transformer for the DC power supply. If 
an auto-transformer (single winding transformer) is used, this product 
or the power supply may get damaged.
In case air bubbles are drawn into the sensing part, take care that it may take 
some time for sensing to stabilize, or sensing may even become unstable.
When liquid remains on the sensing surface after leak detection, wipe all 
liquid from the sensing surface. To avoid scratching the sensing surface 
and the enclosed mounting bracket, use a soft cloth.
If there is liquid remained or scratch on the sensing surface or the 
exclsive mounting bracket, normal operation cannot be performed. 
Since this sensor employs non-modulated infrared LED, take sufficient care against 
extraneous light. Do not expose the sensing part directly to the extraneous light.
Avoid dust, dirt, and steam. Further, do not use this product where oil or 
grease splashes to the product, or in an environment containing corrosive gas, 
etc.
In case this sensor is used where electrostatic charge is present, use a 
metal leak pan, which should be connected to an actual ground.
In case of using this product 50

 or more, be sure to fix this product with 

a dedicated mounting bracket.

I/O CIRCUIT DIAGRAMS

4

Ū

NPN output type

(Brown) +V

(Black) Output

(Blue) 0V

Load


12 to 24V DC

s

10%

Internal circuit

Users' circuit

50mA max.

Sensor circuit

Color code

Ū

PNP output type


(Black) Output

(Blue) 0V

Load

12 to 24V DC

s

10%

Internal circuit

Users' circuit

50mA max.

(Brown) +V

Color code

Sensor circuit

ە

EX-F61

š

(Sensor with PFA mounting bracket)

ە

EX-F62

š

(Sensor with PVC mounting bracket)

DIMENSIONS (Unit: mm)

5

Fixing surface

3 14

19.25

Abnormality indicator
(red)

Normal indicator
(green)

21.5

26

27

PVC mounting bracket

3 14

19.25

Abnormality indicator
(red)

Normal indicator
(green)

2-

ȭ

4.2

4.5

17

PFA mounting bracket

Stainless steel bush

18

27

26

EX-F62

š

ە

ە

Please note that if the excess adhesive from the bottom 
surface of the exclusive mounting bracket is remained, the 
sensing capability may be affected.
Use adhesive for polyvinyl chloride(PVC).

MOUNTING

3

How to fit the sensor body to the exclusive mounting bracket

ە

Align the projections in the sensor body with the notches of 
the exclusive mounting bracket and slide till a click is felt.

Projection

Notches

How to remove the sensor body from the exclusive mounting bracket

ە

Pinch the projections of the sensor body and pull the body 
upwards.
Never pull the cable, since it may cause a cable break.

Projection

EX-F61

š

ە

Insert

the M4 stud-bolt

(length

10mm

or

more)

welded on the user's
facilities into the mounting
hole of the PFA mounting
bracket and screw with an
M4 nut (please arrange
separately). The tightening
torque should be 0.98N

m or 

less. 

M4 nut

M4 stud-bolt

(straight type)

1

INTENDED PRODUCTS FOR CE MARKING

6

ە

ە

The models listed under '

SPECIFICATIONS

come with CE Marking.
As for all other models, please contact our office.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany

Amplifier Built-in Leak Detection Sensor

EX-F60 Series

INSTRUCTION
MANUAL

http://panasonic.net/id/pidsx/global

© Panasonic Industrial Devices SUNX Co., Ltd. 2014

PRINTED IN JAPAN

Overseas Sales Division (Head Office) 
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 
Phone: +81-568-33-7861  FAX: +81-568-33-8591

About our sale network, please visit our website.

Ramco National

800-280-6933 | [email protected]

www.panasonicsensors.com

Summary of Contents for EX-F61

Page 1: ...rial use only Avoid using the product in an explosive atmosphere because this product does not have an explosive proof protective construction Make sure to carry out the wiring in the power supply off condition Take care that wrong wiring will damage the sensor Verify that the supply voltage variation is within the rating Take care that if a voltage exceeding the rated range is applied or if an AC...

Page 2: ... 3 How to fit the sensor body to the exclusive mounting bracket ە Align the projections in the sensor body with the notches of the exclusive mounting bracket and slide till a click is felt Projection Notches How to remove the sensor body from the exclusive mounting bracket ە Pinch the projections of the sensor body and pull the body upwards Never pull the cable since it may cause a cable break Pro...

Page 3: ...use this product does not have an explosive proof protective construction Ɣ Make sure that the power supply is off while wiring Ɣ Take care that wrong wiring will damage the sensor Ɣ Verify that the supply voltage variation is within the rating Take care that if a voltage exceeding the rated range is applied or if an AC power supply is directly connected the sensor may get burnt or damaged Ɣ If po...

Page 4: ... listed under SPECIFICA TIONS come with CE Marking As for all other models please contact our of ce Ɣ Take care not to use the SUS mounting bracket for EX F72Ƒ or the PVC mounting bracket for EX F71Ƒ mistakenly since normal detection cannot be performed Ɣ Make sure to use an isolation transformer for the DC power supply If an auto transformer single winding transformer is used this product or the ...