4
2.
Part Description
!
<Emitter>
Beam-emitting
part
<Receiver>
Operation indicator (Orange)
Lights up when the output is
ON.
Stability indicator (Green)
Lights up under stable
light received condition
or stable dark condition.
Beam-receiving
part
Operation
mode switch
Operation
Description
Light-ON
Light-ON mode is obtained when the operation mode switch is
turned fully clockwise (L side).
Dark-ON
Dark-ON mode is obtained when the operation mode switch is
turned fully counterclockwise (D side).
Note: Use the accessory adjusting screwdriver to turn the operation mode switch slowly. Turning
with excessive strength will cause damage to the adjuster.
Operation mode
switch
<Receiver>
Operation indicator
(Orange)
Lights up when the
output is ON.
Stability indicator
(Green)
L i g h t s u p u n d e r
stable light received
condition or stable
dark condition.
Beam-receiving
part
<Emitter>
Sensitivity adjuster
S e n s i n g r a n g e
increases when
turned clockwise.
Beam-
emitting
part
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]