8
<Installation interval for EX-13
□,
EX-17□>
In case using at sensing distance (L3) 500mm, the
operation point (ℓ3) is approx. 76.6mm according to
diagram above.
The installation interval is
Approx. 76.6mm × 2 = approx. 153.2mm
Thus, install approx. 153.2mm or more away
<Installation interval for EX-13E
□,
EX-17E□>
In case using at sensing distance (L4) 500mm, the
operation point (ℓ4) is approx. 50mm according to dia
-
gram above.
The installation interval is
Approx. 50mm × 2 = approx. 100mm
Thus, install approx. 100mm or more away.
EX-13E
□,
EX-17E
□
:
approx. 100mm or more
EX-13E
□,
EX-17E
□
:
approx. 100mm or more
500mm
Emitter
Receiver
Thru-beam type: EX-13
□,
EX-17
□
parallel deviation diagram (typical)
100
50
0
50
100
(ℓ3)
(L3)
0
800
400
600
200
Thru-beam type: EX-13E
□,
EX-17E
□
parallel deviation diagram (typical)
100
50
0
50
100
(ℓ4)
(L4)
0
800
400
600
200
Sensing distance L
(mm)
Center
Left
Right
Operating point ℓ (mm)
Sensing distance L
(mm)
Center
Left
Right
Operating point ℓ(mm)
EX-13
□,
EX-17
□
approx. 153.2mm or more
500mm
EX-13
□,
EX-17
□
approx. 153.2mm or more
Emitter
Receiver
www.digiparts.ch
Ihr Schweizer Industriepartner