11
Thru-beam type: EX-13S
□,
parallel deviation diagram (typical)
100
50
0
50
100
800
0
600
400
200
(
L9
)
(
ℓ9
)
Sensing distance L
(mm)
Center
Left
Right
Operating point ℓ(mm)
<Installation interval for
EX-13S
□
>
In case using at sensing distance (L9)
500mm, the operation point (ℓ9) is approx.
37.1mm according to diagram above.
The installation interval is
Approx. 37.1mm × 2 = approx. 74.2mm
Thus, install approx.74.2 or more away.
Emitter
Receiver
EX-13S
□
:
approx. 74.2mm or more
500mm
EX-13S
□
:
approx. 74.2mm or more
Thru-beam type: EX-13SE
□,
parallel deviation diagram (typical)
(
L10
)
(
ℓ10
)
100
50
0
50
100
800
0
600
400
200
Center
Left
Right
Operating point ℓ(mm)
Sensing distance L
(mm)
<Installation interval for
EX-13SE
□
>
In case using at sensing distance (L10)
500mm, the operation point (ℓ10) is approx.
29.2mm according to diagram above.
The installation interval is
Approx. 29.2mm × 2 = approx. 58.4mm
Thus, install approx.58.4 or more away.
EX-13SE
□
:
approx. 58.4mm or more
500mm
EX-13SE
□
:
approx. 58.4mm or more
Emitter
Receiver
www.digiparts.ch
Ihr Schweizer Industriepartner