background image

4

3

Important Instructions Before Use

1. Do not confuse self-monitoring with self-diagnosis. Blood pressure

measurements should only be interpreted by a health professional who
is familiar with your medical history.

2. If you are taking medication, consult with your physician to determine the

most appropriate time to measure your blood pressure. NEVER change
a prescribed medication without first consulting with your physician.

3. For persons with irregular or unstable circulation resulting from diabetes,

liver disease, arteriosclerosis or other medical conditions, there may be
variations in blood pressure values measured at the wrist versus at the
upper arm. Monitoring the trends in your blood pressure taken at either
the arm or the wrist is nevertheless useful and important.

4. Blood pressure can vary based on many factors, including age, gender,

weight and physical condition. In general, a person’s blood pressure is
lower during sleep and higher when he or she is active. Blood pressure
can change easily in response to physiological changes. The setting in
which a person’s blood pressure is measured can also affect the results.
Having one’s blood pressure measured by a healthcare professional in a
hospital or clinic can cause nervousness and may result in a temporarily
elevated reading. Because blood pressure measurements taken in a
clinical setting can vary considerably from those taken at home, a
person’s blood pressure should be measured not only occasionally in the
doctor’s office, but also on a regular basis at home. Also, if you find that
your blood pressure is lower at home, this is not unusual. To accurately
compare with your physician’s reading, take your Panasonic blood pressure
monitor to your doctor’s office and compare readings in this setting.

5. People suffering from cardiac arrhythmia, vascular constriction, liver

disorders or diabetes, people with cardiac pacemakers or a weak pulse,
and women who are pregnant should consult their physician before
measuring their blood pressure themselves. Different values may be
obtained due to their condition.

6. Try to take your blood pressure measurements at the same time and

under the same conditions every day.

• The ideal time to measure your blood pressure (to obtain your so-called

“base blood pressure”) is in the morning just after waking up, before
having breakfast and before any major activity or exercise. If this is not
possible, however, try to take measurements at a specified time prior to
breakfast, and before you have become active. You should relax for

Introduction

Thank you for purchasing the Panasonic Wrist Blood Pressure Monitor
EW3003. 

Measuring your own blood pressure is an important way of monitoring your
health. High blood pressure (hypertension) is a major health problem which
can be treated effectively once detected. Measuring your blood pressure
between doctor visits on a regular basis in the comfort of your home, and
keeping a record of the measurements, will help you monitor any significant
changes in your blood pressure. Keeping an accurate record of your blood
pressure will help your doctor diagnose and possibly prevent any health
problems in the future.

Basics of Blood Pressure

Your heart acts like a pump, sending blood surging through your blood
vessels each time it contracts. Blood pressure is the pressure exerted by
blood pumped from the heart on the walls of blood vessels. Systolic
pressure is the pressure exerted when the heart contracts and pumps blood
into the arteries. Diastolic pressure is the pressure exerted when the heart
expands, or relaxes. When you or your doctor take your blood pressure,
both your systolic and diastolic pressures are measured. If your blood
pressure measurement is 120 over 80 (120/80), for example, your systolic
pressure is 120 while your diastolic pressure is 80.

EW3003USA̲Eng  05.1.31 11:18  ページ 3

Summary of Contents for EW3003 - WRIST BP MONITOR

Page 1: ...anasonic Way 3D 1 Secaucus NJ 07094 Before operating this device please read these instructions completely and save this manual for future use Antes de usar este dispositivo lea completamente estas instrucciones y guarde este manual para utilizarlo como referencia en el futuro Wrist Blood Pressure Monitor Monitor de Presión Arterial de Muñeca Operating Instructions Instrucciones de funcionamiento ...

Page 2: ...tion of this device including pulse rate 30 160 pulse min 5 are listed in page 20 Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method within the limits prescribed by the American National Standard Electronic or automated sphygmomanometers If you suffer from disorder of heart rhythm known as ar...

Page 3: ...scular constriction liver disorders or diabetes people with cardiac pacemakers or a weak pulse and women who are pregnant should consult their physician before measuring their blood pressure themselves Different values may be obtained due to their condition 6 Try to take your blood pressure measurements at the same time and under the same conditions every day The ideal time to measure your blood p...

Page 4: ... are taking a bath during exercising or soon after exercising when it is cold within one hour after eating after drinking coffee tea or other beverages containing caffeine after smoking tobacco when your bladder is full Blood pressure will be lower than usual after taking a bath after drinking alcohol 7 Measurements may be impaired if this unit is used near a television microwave oven X ray equipm...

Page 5: ...Slide the battery cover back into place on the main body until it clicks in place Fig 2 c Fig 2 a Fig 2 b Fig 2 c NOTES Batteries are included only for testing pur poses and with no guarantee of battery life Do not mix old and new batteries The batteries power output is impaired at low temperatures Caution Do not throw batteries into a fire Doing so may result in an accident or explosion IMPORTANT...

Page 6: ...curing with hook and loop fastener Leave main unit at the distance of 2 cm 3 4 from the first wrinkle line of wrist palm joint mount the cuff on the wrist in such way as the center of the main unit locates at the center of the wrist Fig 4 a 3 Attach the right thumb on the harder part intensely from the side so that the right side of the cuff is sure to be fixed on the side face of the wrist secure...

Page 7: ...the slightest change such as tensing your muscles or changing your posture If the blood pressure monitor is positioned lower than the heart the measured blood pressure value may be high If the blood pressure monitor is positioned higher than the heart the measured blood pressure value may be low If the posture applies pressure to the stomach leaning forward accurate measurements may not be possibl...

Page 8: ...ress the On Off and Start button Fig 6 a All displays on the unit will light up for approx 2 seconds Fig 6 b The cuff will begin to inflate automatically Changing inflation speeds and operating sounds occur during inflation and are a normal part of the measurements that are being performed at this time 2 With fingers lightly clenched to form a fist position your free hand beneath the arm of the wr...

Page 9: ...ntil all readings are deleted NOTE Readings from individual measurements cannot be deleted 3 When data has been deleted the mark and will be displayed on the screen Fig 10 a Fig 10 b CAUTION For persons with poor circulation resulting from diabetes liver disease arteriosclerosis high blood pressure or other conditions there may be significant differences in blood pressure values measured at the wr...

Page 10: ...e is attached straighten it out Fig 11 a Fig 11 b NOTE When the batteries are removed the date time and measurement record are erased Set the date and time again the next time you use the unit Troubleshooting Display The blinks on the display Status before error Pressurization to above 280 mmHg was performed Re pressurization was performed several times Pressure decreased suddenly and appeared in ...

Page 11: ...g inflation of the cuff The measured value obtained is different from that measured at the upper arm Possible cause The hand with the cuff was held too low and not at heart level See page 9 The cuff was not attached properly See page 9 You moved your hand or body or you spoke during measurement See page 9 The hand with the cuff was held too high and not at heart level See page 9 You moved your han...

Reviews: