16
General Installation Manual
MOUNTING EVPXXXXPK SERIES MODULES WITH CONTINOUS RAILS PARALLEL TO SHORT SIDE OF THE MODULE
A continous rail (or other support structure) spans the complete underside of the module.
CAUTION
The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to
be rated to that load (Figure 15.).
If the panel is secured in zones with different load values, it is rated to the lowest load value only.
**Gap between the uppermost part of the installation surface(e.g. rooftop) and the lowest part of the panel (i.e. underside of panel frame)
Figure 15. Clamping of EVPVxxxPK Series modules with rails parallel to short side of the module
14.1 in [357 mm]
22.9 in [582 mm]
24.5 in [622 mm]
28.0 in [712 mm]
0
0
0
8.9 in [225 mm]
0
0
9.8 in [250 mm
]
3.9 in [100 mm
]
0
9.8 in [250 mm
]
3.9 in [100 mm
]
9.8 in [250 mm
]
3.9 in [100 mm
]
9.8 in [250 mm
]
3.9 in [100 mm
]
14.1 in [357 mm]
22.9 in [582 mm]
24.5 in [622 mm]
28.0 in [712 mm]
8.9 in [225 mm]
Legend
Clearance Gap
**
Clamping zone
0.8 - 1.6 in (20-40 mm)
1.6 - 2.4 in (40-60 mm)
>2.4 in (>60 mm)
<0.8 in (<20 mm)
Test Load
(Design Load)
Test Load
(Design Load)
Test Load
(Design Load)
Test Load
(Design Load)
Rail position
0 - 8.9 in
(0 - 225 mm)
X
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+2400 Pa / -2400 Pa *
(+1600 Pa / -1600 Pa)
X
8.9 - 14.1
(225 - 357 mm)
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
+4200 Pa / -2400 Pa
(+2800 Pa / -1600 Pa)
+5400 Pa / -2400 Pa
(+3600 Pa / -1600 Pa)
X
14.1 - 22.9 in
(357 - 582 mm)
+1800 Pa / -1800 Pa *
(+1200 Pa / -1200 Pa)
+6200 Pa / -4000 Pa
(+4133 Pa / -2666 Pa)
+7000 Pa / -4000 Pa
(+4666 Pa / -2666 Pa)
X
22.9 - 24.5 in
(582 - 622 mm)
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+3000 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
+5400 Pa / -2400 Pa
(+3600 Pa / -1600 Pa)
X
24.5 - 28.0 in
(622 - 712 mm)
+2400 Pa / -2400 Pa *
(+1600 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
X
Rail position
0 - 4 in
(0 - 100 mm)
X
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
X
4 - 9.8 in
(100 - 250 mm)
X
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
X
Once a module is secured in each of the 4 zones (Figure 8.), additional clamps, i.e., ≥5, may be freely located on panel
frame without affecting the warranty. Loads marked with a * were not certified as part of UL 61730 testing; these have been
evaluated by internal testing process.
L
on
g
S
id
e
M
ou
nt
in
g
S
ho
rt
S
id
e
M
ou
nt
in
g
INSTALLATION OF EVPXXXXPK SERIES MODULES