12 - ENGLISH
Installation (continued)
When mounting to a reinforced wall with wood screws
Reinforcement
Shaft
Wall
Attachment plate
Falling prevention wire
A: Mounting holes for wood
screws with nominal diameter
of 3.1 mm (1/8")
Wood screw with nominal
diameter of 4.1 mm (5/32")
Wood screws with
nominal diameter of
3.1 mm (1/8")
A: Mounting holes for wood
screws with nominal diameter
of 3.1 mm (1/8")
B: Mounting holes for wood
screws with nominal diameter
of 4.1 mm (5/32")
Wood screws with nominal
diameter of 3.1 mm (1/8")
Wood screws with
nominal diameter of
4.1 mm (5/32")
1) Drill mounting holes in reference to “Mounting hole dimensions” (
page 10).
z
When mounting to the wall, set the pole of the projector at the upper end.
z
There are two installation methods for choice.
A: This method uses 4 wood screws (3.1 mm (1/8")) to fix the attachment plate.
B: This method uses 4 wood screws (4.1 mm (5/32")) to fix the attachment plate.
Depending on the reinforcement type, use method A (4 holes) or B (4 holes) accordingly.
z
Add marks to the wood screw installation positions (4 holes) on the wall.
2) Mounting the attachment plate to the wall.
z
According to the selected method as described above, use commercially available wood screws with a
nominal diameter of 4.1 mm (5/32") or 3.1 mm (1/8") to secure the attachment plate.
z
If the wall for mounting product is not strong enough, the product may fall and subject to damages, etc. Do
give consideration to the safety factor and provide sufficient reinforcement.
z
For the wall with reinforcement, ensure there is thread engagement of at least 20 mm (25/32") in the wall
reinforcement member.
3) Install the falling prevention wire to the wall.
z
The falling prevention wire is secured to the attachment plate with tape.
z
Rip off the tape and use a commercially available wood screw with a nominal diameter of 4.1 mm (5/32")
to secure the free end of the falling prevention wire to the wall through the larger circular hole on the
attachment plate.
Attention
z
When installing the attachment plate to the wall with wood screws, make sure the falling prevention wire is
installed to the wall.