1. Remove the attachment and blade.
2. Loosen a screw and remove the bottom cover.
3. Insert a slotted-head screw driver (less than 2.4mm width
on top) into the slit of dial cover and raise it with the driver.
NOTE: Make sure there is NO scratch or damage on the
parts.
4. Loosen a screw and take out the dial mounting base, the
trimming length indicator ring with the dial.
5. Loosen two screws tightening the blade spring.
3 DISASSEMBLY INSTRUCTIONS
Follow the procedure below to disassemble the main body.
3
ER217-E2