background image

Thin Type Ionizer 

ER-VW

7

• This product is to remove static electricity

for industrial use. Never use this product for

medical equipment etc. relating to maintenance /

supervision of human life or body, for prevention

of accidents which damage a human life or

properties, or for safety maintenance.

• Do not use this product near or around surroundings

containing any dangerous materials, such as

combustible material and flammable material.

• The discharge needle gathers dust after

a long period of use. In order to prevent

accident or product malfunction, clean up the

discharge needle, periodically once every

one week or so, or this product will be unable

to exert the charge removal performance.

Be sure to ground the main body of this

product via ground terminal to ensure electric

shock prevention and reliable charge removal.

• Since the discharge needle is live with high

voltage, never touch the discharge needle,

or an electric shock may result.

• If this product is used in an airtight room, ozone

emitted from this product may be detrimental.

Therefore, in order for this product to be used in an

airtight room, be sure to keep the room ventilated.

• Since the ion air contains ozone, do not aim

this product at anyone.

• Always be sure to turn off the air supply before

loosening the nozzles to carry out air flow

adjustment or for maintenance. Air pressure

may cause the discharge needle to fly out.

Furthermore, push the nozzle securely in by

hand until it touches into the enclosure of the

device afterwards, and check that the nozzle

does not move. If the nozzle is not installed

correctly, it will adversely affect charge removal

performance and the nozzle may also fall out.

• Since the tip of the discharge needle is

pointed, take sufficient care in handling the

discharge needle, or injuries may result.

Mounting

• When installing the unit to

its mount, use M4 pan head

screws (please arrange

separately), and tighten them

at a torque of 0.5 N·m or less.

Be sure to connect the F.G.

terminal to ground. If the unit is 

not properly grounded, charge

removal performance will be severely reduced. (Use a

type D ground or a common power supply ground.)

• If grounding to a common power supply ground, you can

use the lead wire for connecting the F.G. that is supplied

with the unit to make the connection.

0 V ground: Connect pins 2 and 3 of the end connector

(9-pin) to the lead wire for connecting the F.G..

+V ground: Connect pins 1 and 3 of the end connector

(9-pin) to the lead wire for connecting the F.G..

If the ground is not connected correctly, operating 

problems or accidents may occur, so be sure to 

check the usage conditions and connect the ground 

in such a way that the power supply does not 

become shorted.

Nozzle 

M4 pan head 

screw 

Purchase

separately.

Adjusting the air blowing direction

• After screw down the nozzle to loosen it, point it toward

the object to be charge removal. After adjusting the

position, securely tighten the nozzle by hand until it is

touching the enclosure, and check that the nozzle does

not move. If the nozzle is not installed correctly, it will

adversely affect charge removal performance and the

nozzle may also fall out.

• The diagram at right shows the range of

adjustment for the nozzles.

100°

90°

Piping

• The tube that is installed to the air intake of this device

should have an outside diameter of 6 mm 

0.236 in

 and an

inside diameter of 4 mm 

0.157 in

.

• The air that is supplied to this product should be dried

clean air that has been processed through an air dryer

(dew point around –20 °C 

–4 °F

) and an air filter

(mesh size around 0.01µm 

0.0004 mil

).

• Increasing the length of the air hose from the air supply

equipment or adding pneumatic equipment (such as

a needle valve, governor or miniature filter) will cause

drops in the pressure of the air supplied to the device,

and so do not allow the air pressure to drop below

sufficient levels. (Check the pressure applied to the

device at the air intake of the device.)

Furthermore, select air pressure equipment that is

appropriate for the level of supplied air flow.

Connections

• Use the 

ER-VWAR80

 joint kit (optional) to connect

the devices together. (1 kit is needed for each pair of

devices.) Up to a maximum of 5 units can be connected

together (including this unit).

When using units that are connected together in this way,

attach the supplied end connector to the connector of the

last device in the series. Furthermore, also connect the

end connector to a device if not connecting the device to

any other devices.

• The air joint (included in the joint kit) should be tightened

at a torque of 0.5 N·m or less.

• When connecting devices together, check that the air

pressure values at the air intakes of each device are

appropriate for the usage conditions.

Connector attached 

cable (Accessory) 

End connector (Accessory) 

Power & I/O connector (8-pin) 

Cable for joint 

Be supplied with joint kit 

(

ER-VWAR80

) (optional) 

Joint connector (9-pin) 

Air tube joint [Be supplied with joint kit (

ER-VWAR80

) (optional)] 

Air tube (ø6 mm 

0.236 in

(Purchase separately.)

PRECAUTIONS FOR PROPER USE

Summary of Contents for ER-VW

Page 1: ...2022 7 High frequency AC Method The contents of this catalog are as of October 2017 For the latest information please visit our company website Thin Type Ionizer ER VW ...

Page 2: ...ct up to a maximum of 5 ER VW units The air supply part is connected via quick connection joints and the power supply and input output signals can also be connected easily using connection cables with connectors at both ends Multiple ER VW units can be connected together to provide charge removal layouts that suit the target equipment End connector Accessory Cable with connector Accessory Air supp...

Page 3: ...jacent production lines MOUNTING SIZE Comparison of air consumption Notes 1 Minimum width dimensions after nozzle angle adjustment 2 Maximum width dimensions after nozzle angle adjustment ER VW Previous spot type Minimum 100 ℓ min ANR to Maximum 300 ℓ min ANR Air consumption ℓ min ANR 300 200 100 0 Minimum 15 ℓ min ANR Maximum 60 ℓ min ANR to In contrast to previous low frequency types and DC type...

Page 4: ...arge Air supply Discharge halt Ionizer main unit One each of connector attached cable length 0 5 m 1 640 ft end connector and lead wire for connecting F G are supplied with the ionizer main unit Type Appearance Charge removal time 1 000 V 100 V Ion balance Model No Spot type 1 sec or less Note 1 10 V or less Note 1 ER VW Note 2 Notes 1 A typical sample applied with a supply voltage of 24 V a dista...

Page 5: ...tput and 0 V Residual voltage 1 V or less at 50 mA sink current Output operation Check output CHECK ON when the discharge needle is dirty or worn OFF when operation is normal Error output ERROR OFF when abnormal discharge is detected ON when operation is normal Discharge output DSC Note 5 ON when discharging OFF when discharge halts Short circuit protection Incorporated Discharge halt input DSC OF...

Page 6: ...harge plate monitor At center of CPM Air flow Correlation between charge removal distance and ion balance Correlation between charge removal distance and charge removal time Charge removal field 0 50 MPa Connector terminal arrangement Power I O connector Joint connector 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 1 Non voltage contact or NPN open collector transistor or Discharge halt input Low 0 V Discharg...

Page 7: ...ins 1 and 3 of the end connector 9 pin to the lead wire for connecting the F G If the ground is not connected correctly operating problems or accidents may occur so be sure to check the usage conditions and connect the ground in such a way that the power supply does not become shorted Nozzle M4 pan head screw Purchase separately Adjusting the air blowing direction After screw down the nozzle to lo...

Page 8: ...o this product should be limited in length to less than 10 m 32 808 ft When this product is no longer usable or required dispose of properly as industrial waste Always be sure that the power supply and the air supply are both turned off before inspection and cleaning Be sure to turn off the air before removing the nozzles for purposes such as maintenance Air pressure may cause the discharge needle...

Page 9: ...3 ø4 5 ø0 177 mounting holes 16 3 0 642 2 0 079 16 9 0 665 4 8 0 189 40 1 575 110 4 331 80 3 150 7 0 276 60 2 362 15 3 0 602 127 5 000 Plug with hexagonal hole Joint for ø6 mm ø0 236 in air tube 42 1 654 2 ø14 4 ø0 567 DIMENSIONS Unit mm in The CAD data can be downloaded from our website ...

Page 10: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent rights of a third party Printed in Japan Industrial Device Business Division 7 1 1 Morofuku Daito shi Osaka 574 0044 Japan industrial panasonic com ac e ⓒ Panasonic Industry Co Ltd Specifications are ...

Reviews: