background image

4

Thin Type Ionizer 

ER-VW

Air supply monitoring function

This function causes discharging to stop automatically if the 

supply of air drops below a certain pressure. Notification of 

this is given when the AIR indicator lights and the discharge 

output (DSC) turns off. This prevents objects which are not 

charged from being overlooked when the air supply has 

been stopped.

FUNCTIONS

The functions support accurate charge removal

In addition to the air supply monitoring function, the 

ER-VW

 

is equipped with the following functions to ensure accurate 

charge removal.

Discharge halt function

•Check function

Abnormal discharge 

monitoring function

Discharge output

•Check output

Error output

: Uses external input to forcibly stop discharge.

Uses the CHECK indicator and output to notify the operator 

when it is time to clean or replace the discharge needle.

: Uses the ERROR indicator and output to notify the 

operator when a problem with discharge occurs, and stops 

discharge. It can be canceled by means of reset input.

: Output is ON during discharging. This lets you 

check when discharging is being carried out.

: Output turns ON when the discharge needle is dirty.

: Output turns OFF when there is a problem with 

discharging (normally it is ON). It also allows you to 

check the power supply to the ionizer.

Discharge

DSC

Abnormal discharge

ERROR

Power supply

POWER
Discharge needle condition

CHECK
Air supply monitoring

AIR

New concept

Air supply

Discharge

Air supply

Discharge halt

Ionizer main unit

One each of connector attached cable (length 0.5 m 

1.640 ft

), end connector and lead wire for connecting F.G. are supplied with the ionizer main unit.

Type

Appearance

Charge removal time

(±1,000 V → ±100 V)

Ion balance

Model No.

Spot type

1 sec. or less (Note 1)

±10 V or less (Note 1)

ER-VW 

(Note 2)

Notes: 1) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 

3.937 in

 from the front surface of the air flow outlet and a pressure of 0.25 

MPa.(Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)

2) The PNP output type is also available.

ORDER GUIDE

Connector attached cable

ER-VWCC□

Note: One connector attached cable (length 0.5 m 

1.640 ft

) is supplied with the ionizer main unit. 

Please order it, if you need.

Type

Model No.

Description

Connector 

attached cable

(Note)

ER-VWCC2

Length: 2 m 

6.562 ft

,

Net weight: 52 g approx.

0.15 mm

2

 8-core cabtyre cable with 

connector

Cable outer diameter:  ø4.2 mm 

ø0.165 in

ER-VWCC5

Length: 5 m 

16.404 ft

,

Net weight: 120 g approx.

ER-VWCC9

Length: 9 m 

29.528 ft

,

Net weight: 240 g approx.

Mini line filter

ER-AF10

Processed air volume

40 ℓ/min. (ANR)

Removes solid particles such as 

dirt and dust from air supply

•  Collected particle dia.:  0.1 µm

0.004 mil

• 

Collection efficiency: 99.9 %

ER-AF20

Processed air volume

80 ℓ/min. (ANR)

Discharge needle unit

ER-VWANT

Unit with replacement tungsten needles (2 needles per set)

Joint kit

ER-VWAR80

Connection cable (cable length 0.8 m 

2.625 ft

) and air tube 

joint: 1 pc. each

Discharge needle unit

ER-VWANT

OPTIONS

* The photograph 

shows 

ER-AF10

Mini line filter

ER-AF10

ER-AF20

Summary of Contents for ER-VW

Page 1: ...2022 7 High frequency AC Method The contents of this catalog are as of October 2017 For the latest information please visit our company website Thin Type Ionizer ER VW ...

Page 2: ...ct up to a maximum of 5 ER VW units The air supply part is connected via quick connection joints and the power supply and input output signals can also be connected easily using connection cables with connectors at both ends Multiple ER VW units can be connected together to provide charge removal layouts that suit the target equipment End connector Accessory Cable with connector Accessory Air supp...

Page 3: ...jacent production lines MOUNTING SIZE Comparison of air consumption Notes 1 Minimum width dimensions after nozzle angle adjustment 2 Maximum width dimensions after nozzle angle adjustment ER VW Previous spot type Minimum 100 ℓ min ANR to Maximum 300 ℓ min ANR Air consumption ℓ min ANR 300 200 100 0 Minimum 15 ℓ min ANR Maximum 60 ℓ min ANR to In contrast to previous low frequency types and DC type...

Page 4: ...arge Air supply Discharge halt Ionizer main unit One each of connector attached cable length 0 5 m 1 640 ft end connector and lead wire for connecting F G are supplied with the ionizer main unit Type Appearance Charge removal time 1 000 V 100 V Ion balance Model No Spot type 1 sec or less Note 1 10 V or less Note 1 ER VW Note 2 Notes 1 A typical sample applied with a supply voltage of 24 V a dista...

Page 5: ...tput and 0 V Residual voltage 1 V or less at 50 mA sink current Output operation Check output CHECK ON when the discharge needle is dirty or worn OFF when operation is normal Error output ERROR OFF when abnormal discharge is detected ON when operation is normal Discharge output DSC Note 5 ON when discharging OFF when discharge halts Short circuit protection Incorporated Discharge halt input DSC OF...

Page 6: ...harge plate monitor At center of CPM Air flow Correlation between charge removal distance and ion balance Correlation between charge removal distance and charge removal time Charge removal field 0 50 MPa Connector terminal arrangement Power I O connector Joint connector 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 1 Non voltage contact or NPN open collector transistor or Discharge halt input Low 0 V Discharg...

Page 7: ...ins 1 and 3 of the end connector 9 pin to the lead wire for connecting the F G If the ground is not connected correctly operating problems or accidents may occur so be sure to check the usage conditions and connect the ground in such a way that the power supply does not become shorted Nozzle M4 pan head screw Purchase separately Adjusting the air blowing direction After screw down the nozzle to lo...

Page 8: ...o this product should be limited in length to less than 10 m 32 808 ft When this product is no longer usable or required dispose of properly as industrial waste Always be sure that the power supply and the air supply are both turned off before inspection and cleaning Be sure to turn off the air before removing the nozzles for purposes such as maintenance Air pressure may cause the discharge needle...

Page 9: ...3 ø4 5 ø0 177 mounting holes 16 3 0 642 2 0 079 16 9 0 665 4 8 0 189 40 1 575 110 4 331 80 3 150 7 0 276 60 2 362 15 3 0 602 127 5 000 Plug with hexagonal hole Joint for ø6 mm ø0 236 in air tube 42 1 654 2 ø14 4 ø0 567 DIMENSIONS Unit mm in The CAD data can be downloaded from our website ...

Page 10: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent rights of a third party Printed in Japan Industrial Device Business Division 7 1 1 Morofuku Daito shi Osaka 574 0044 Japan industrial panasonic com ac e ⓒ Panasonic Industry Co Ltd Specifications are ...

Reviews:

Related manuals for ER-VW