background image

OPERATING PRECAUTIONS

WARNING: To avoid damaging to the chair, follow these precautions:

1. The chair is designed for a maximum user weight of 264lbs (120k

g)

.  Exceeding the maximum weight may

cause permanent damage to the massage mechanism and/or other components of the chair.  Any such
damage is deemed to be user abuse and is not covered under the Limited Warranty.  

2. Do not sit on or drop the controller.  Do not pull the controller cord or the power cord.  Be careful not to catch

the cord of the controller between the armrest and the chair back.  

3. Do not treat the chair roughly, such as turning the chair on its side, turning the chair over or standing on it.  

4. Do not treat the covering roughly.

• Keep sharp or pointed objects away from the covering of the chair. Be careful not to drop lit ashes, lit cigarette

or matches on the chair.  

• Exposure to direct sunlight can cause fading or a change in color of the covering.

5. If the massager functions abnormally, immediately turn off the power and have the massager checked by an

authorized service center.

6. Do not attempt to repair the massager yourself.  

7. Do not repeatedly operate any switch at short intervals. Such action may cause the switch to malfunction.

8. Some noise may be heard coming from the massager while in use.  This is due to the structure of the

massager and is normal.  

9. Make sure there are no obstacles behind the chair before reclining it.  The chair can be reclined to a maximum

angle of 170°.  If the back hits a wall or pillar, the chair may malfunction. Be sure to have ample space behind
the chair. Recline the chair slowly in order to avoid contact with an obstacle.

10. When excessive pressure is applied to the massage heads, they may stop moving for safety. When moving the

heads up from the lowered position, one’s body weight may stop the heads’ movement. In such case, slightly
raise the body and allow the massage heads to move up.

11. After each massage, slide the power switch, which is located on the back of the chair, to the “off” position and

turn its lock switch to the “lock” position.

12. Do not sit on massage chair with wet body or hair. 

13. The massage Lounger must not be used in “wet rooms” (sauna, swimming pool) or out of doors. 

SAFETY PRECAUTIONS

WARNING: To avoid the risk of injury, follow these precautions:

1. Pregnant women, people who are ill, in poor physical shape or undergoing medical treatment, and people

suffering from back, neck, shoulder or hip pain should consult their doctor before using the unit.  If you have a
pacemaker, defibrillator, or other personal medical device, consult with the manufacturer of your device before
using the unit.  Your physician may be able to assist you in obtaining this information.  

2. Sit down slowly after checking the position of the massage heads.  Never put any part of your body between

the massage heads as the squeezing action of the massage heads may cause injury.  Never put your fingers or
feet in the gap between the backrest and seat, the backrest and the armrest, the seat and cover under the
armrest, or the gap between the legrest and the footrest.  Do not place your fingers or any part of your body in
the mechanical section of the legrest located under the seat.

3. Do not use the unit against bare skin.  While thin clothing may increase effectiveness, exposing the skin directly

to the massager may irritate the skin.  
Do not use the unit while wearing anything hard on your head like a hair accessory, etc.  

4. Do not use the unit for massaging the head, abdomen, elbows or knees.   

5. Always check that the shoulder position is correct.  If it is not correct, use the Neck Roller Position Adjustment

Button to adjust it properly (In programmed operation). 

6. Do not stretch the back muscles for more than approximately 15 minutes at a time.  To avoid overstretching the

muscles which may result in discomfort, do not use the unit for more than 5 minutes when first using it.  You
can gradually increase the duration and intensity of the massage as you become used to it.  
Do not massage any one point for more than 5 minutes at a time.  
To prevent excessive massaging, do not use the massager for more than a total of 15 minutes each session.
After approximately 15 minutes, the massage heads will be retracted and stop moving.  

7. While using the unit, if you start feeling sick or if the massage seems painful, stop using it immediately.  

While using the massager, if the pressure seems too strong, the movement of the massage heads can be
stopped at any time by pressing the Stop Button.

8. Do not go to sleep while using the unit.  Do not use the unit after drinking alcohol.  

9. When the seat back is in a reclined position, do not sit on it or sit with your legs resting on the headrest.  

Do not sit on the legrest as the unit may fall over.

10. Do not allow children or pets to play on or around the unit, especially during operation.  

11. Do not unplug the unit or turn it off during operation.  Unplug the unit immediately if there is a power

interruption.  

12. For those who are trying the massage for the first time, it is recommended to start on the gentle massage

program. The shiatsu massage is stronger and should be enjoyed after one has gotten accustomed to the
chair.

4

5

CARING FOR THE MASSAGER

• Always unplug the chair before cleaning.
• If the covering becomes soiled, dampen with liquid soap and brush the surface. Wipe with a cloth dampened with

water.  Allow to dry naturally.  If the plastic portions become soiled use lukewarm water, with liquid soap on a soft
cloth, to clean the surface.

• Do not use thinner, benzene or other solvent-type cleaners. Chemicals can discolor or damage the materials.

Summary of Contents for EP1060K

Page 1: ...zar esta unidad lea completamente estas instrucciones y gu rdelas por si necesita consultarlas en el futuro Sillón de masaje Instrucciones de uso Modelo No Panasonic Consumer Electronics Company One Panasonic Way 3D 1 Secaucus New Jersey 07094 1 800 338 0552 for questions and comments www panasonic com massage No 2 EN SP アメリカ Printed in Japan P90101060231 ...

Page 2: ...r cord or plug Return the unit to the nearest authorized service center if it is not working properly if it has been dropped or damaged or if it has been immersed in water 9 Always raise the center cushion to check that the fabric of the unit itself has not been ripped before using the unit Please also check other areas to ensure that the fabric has not been ripped No matter how small the rip if y...

Page 3: ...t down slowly after checking the position of the massage heads Never put any part of your body between the massage heads as the squeezing action of the massage heads may cause injury Never put your fingers or feet in the gap between the backrest and seat the backrest and the armrest the seat and cover under the armrest or the gap between the legrest and the footrest Do not place your fingers or an...

Page 4: ... grounded Do not modify the plug provided with the product even if it does not fit the outlet Have a proper outlet installed by a qualified electrician This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug shown in Figure A Make sure that the product is connected to an outlet having the same configuration as the plug No adaptor should be used with ...

Page 5: ...e neck roller position reclining programmed operation manual operation intensity roll manual operation whole back regional tap A vibration tap B swedish shiatsu knead position slow fast leg massage ON OFF Button ON OFF Lamp Cover Closed Cover Open Used to stop the massage immediately Quick Stop Button Used to adjust the angle of the backrest and legrest Reclining Button Displays operational mode M...

Page 6: ...top An average program massage is 15 17 minutes Manual Operation Used for selecting a particular massage movement or area to be massaged Ideal for people who want to adjust movement and location during the course of a massage Ideal for people who want just a little more on the shoulders at the end of their massage z Open the cover of the controller and select the massage required x The seat will a...

Page 7: ...e backrest Do not sit down if the massage heads are not in the retracted position Instead push button twice to retract the massage heads to the proper position If button is pushed during the massage then the massage heads will not be retracted Please do not sit on the controller as the reclining button may be pressed causing the seat to automatically recline Sit Down Only When the Legrest is Lower...

Page 8: ...t their entire back Massage starts out predominantly in the upper back Gently Massage the Whole Back This type of massage is ideal for people who are feeling tired or weary It is gentler than shiatsu massage more like a sewedish palm massage When the Shoulder Position Indicator is flashing adjust the position of the massage heads upper roller so that they lightly touch the shoulder The shoulder po...

Page 9: ... roll manual operation whole back regional tap A vibration tap B swedish shiatsu knead E g 3 Toggling off Roll pressing it again roll manual operation whole back regional tap A vibration tap B swedish shiatsu knead roll manual operation whole back regional tap A vibration tap B swedish shiatsu knead E g 2 Adding Roll to the selection roll manual operation whole back regional tap A vibration tap B ...

Page 10: ...G MASSAGE IN MANUAL OPERATION EP1061 slow fast leg massage slow fast leg massage slow fast leg massage slow fast leg massage slow fast leg massage slow fast Off Press Press Press Press Soles of feet Calves If your calves are not in the correct position in the legrest please adjust your legs so that they are 1 Press button The programmed operation and leg massage button will flash 2 Press the Leg M...

Page 11: ...p A Roll Swedish Roll and Swedish Tap A Roll Shiatsu Vibration Roll and Shiatsu Vibration Tap A Swedish Roll and Swedish Tap A Roll Swedish Roll Swedish Tap A Roll and Swedish Vibration Roll Swedish Vibration Swedish Vibration and Swedish Tap A Roll 2 3 6 5 4 7 8 9 Swedish Tap A Roll Swedish and Roll 10 20 1 Turn Off the Power z Turn the power switch to the off position x Turn the lock switch to t...

Page 12: ...though programmed operation lasts for approximately 15 minutes 12 17 minutes this will vary according to the shoulder position and program selected whether or not tapping is on or off and the weight of the person using the unit The movements below are shown in simplified form for the sake of illustration When the programs have finished the unit will automatically stop Although programmed operation...

Page 13: ...r socket when you have finished Failure to do so may lead to electric shock or burns CAUTION 24 This feels as though the thumbs of both hands are being used to work on the acupressure points The initial strong push is followed by a short pause to give the impression of a professional shiatsu masseur This type of massage is ideal for people with tight muscles and pain who want a point massage Shiat...

Page 14: ... and then turn the power switch on again H 26 Problem Cause and Remedy Motor Noises The motor gets louder when it comes under load There is excessive noise during Tapping The noise is louder at the top of the unit The motor sounds louder when adjusting massage intensity and width There is a rubbing sound produced by the massage heads rubbing on the seat fabric There is a rubbing sound produced by ...

Page 15: ...6 31 5 65in 60 80 165cm Weight 128 lbs 58kg Maximum user weight 264 lbs 120kg SPECIFICATIONS EP1061 Power Supply 120V AC 60Hz Power Consumption 135W Approx 5W in Standby mode with the controller turned off or when the unit is turned off Upper Body Massage Massage Area Up Down Approx 27 6in 70cm Massage Area Left Right Distance between Massage Heads during Operation Approx 2 4 5 9in 6 15cm Massage ...

Page 16: ...ona correctamente se ha caído dañado o sumergido en agua llévela al centro de asistencia autorizado más próximo 9 Levante siempre el cojín central para comprobar que el tapizado de la unidad no ha sufrido rasgaduras antes de su uso Inspeccione además otras áreas para asegurarse de que el tapizado se encuentra en perfecto estado En caso de descubrir cualquier rasgadura independientemente de su tama...

Page 17: ...éctrica 12 A las personas que intentan darse un masaje por primera vez se les recomienda empezar un programa de masaje suave El masaje shiatsu es muy fuerte por lo que deberá ser disfrutado cuando uno se hay acostumbrado a la silla PRECAUCIONES PARA EL FUNCIONAMIENTO ADVERTENCIA Para evitar dañar el asiento siga estas precauciones 1 El asiento está diseñado para soportar un peso máximo de 264lbs 1...

Page 18: ...to aunque ésta no pueda conectarse en la toma de corriente Pida a un electricista cualificado que le instale una toma de corriente apropiada Este producto ha sido diseñado para funcionar con una corriente nominal de 120 voltios y tiene una clavija de conexión a tierra como la mostrada en la figura A Asegúrese de que el producto esté conectado a una toma de corriente que tenga la misma configuració...

Page 19: ... rodillos de masaje Sirve para acomodar la posición de los hombros Botón de ajuste de posición de hombros Indicadores de posición de hombros Botones modo programado Sirven para seleccionar la zona donde debe concentrarse el masaje Botones para zonas localizadas Se usa en el modo programado Botón de encendido apagado de vibración Indicador de intensidad Sirve para seleccionar la intensidad del masa...

Page 20: ... de bloqueo a su posición bloqueada lock c Desenchufe el cable de alimentación eléctrica A continuación describimos el modo de uso general del sillón de masaje Para obtener mayor detalle consulte las páginas indicadas USO DEL SILLÓN DE MASAJES INTRODUCCIÓN Si se aplica una presión excesiva sobre los rodillos de masaje durante el masaje de la parte superior del cuerpo por motivos de seguridad los r...

Page 21: ...á levantado pulse el botón para descenderlo antes de sentarse ADVERTENCIA Para evitar el peligro de lesionarse no ponga sus dedos o ninguna parte de su cuerpo en la sección mecánica del reposapiernas reclining reclining 170 aprox Ángulo de inclinación 120 aprox 85 aprox Ángulo de elevación 0 aprox Ángulo de inclinación Ángulo de elevación reclining Pulsar Pulsar Premere Para abrir el dispositivo d...

Page 22: ...eccione una zona para el masaje localizado Consulte las páginas 47 49 para obtener más detalles con respecto a los programas 7 Parada automática con el modo programado Una vez finalizado el programa seleccionado la unidad se detendrá automáticamente Aunque la duración del modo programado es de 15 minutos aprox entre 12 y 17 esto variará de acuerdo con la posición de los hombros del programa selecc...

Page 23: ... moviéndose hasta soltar el botón Cuando los rodillos de masaje alcanzan su límite se oye un pitido triple Ajustar la separación entre los rodillos de masaje Las opciones Vibración Percusión Shiatsu Rodamientos de espalda completa y Rodamientos locales se pueden ajustar en 5 niveles mientras que la opción Sueco sólo tiene 3 niveles El masaje sueco abarca toda la espalda por lo tanto no es posible ...

Page 24: ...ón para detener el masaje de piernas 44 MASAJE DE PIERNAS CON EL MODO MANUAL EP1061 slow fast leg massage slow fast leg massage Alto Bajo Apagado slow fast leg massage slow fast leg massage slow fast leg massage Pulsar Pulsar Pulsar Pulsar Plantas de los pies Pantorrillas Si sus pantorrillas no se encuentran en la posición correcta sobre el reposapiernas posicione las piernas correctamente 1 Pulse...

Page 25: ...minutos aprox entre 12 y 17 esto variará de acuerdo con la posición de los hombros del programa seleccionado independientemente de si la percusión está activada y del peso de la persona que está usando la unidad FUERTE SUAVE Parte superior del cuerpo DETALLES DEL MODO PROGRAMADO 1 Rodamientos Shiatsu y Amasar Rodamientos Amasar Rodamientos y Shiatsu Vibración Sueco Percusión B Rodamientos y Shiats...

Page 26: ...CUELLO Y HOMBROS SUAVE ZONA LUMBAR Parte superior del cuerpo 1 Rodamientos Amasar y Sueco Percusión A Rodamientos Sueco Sueco Vibración y Sueco Percusión A Vibración Sueco y Sueco Percusión A Rodamientos Percusión A Sueco Rodamientos y Sueco Percusión A Rodamientos Sueco Sueco Vibración y Sueco Percusión A Rodamientos Percusión A Sueco Rodamientos y Sueco Percusión A Rodamientos Sueco Sueco Vibrac...

Page 27: ...enceno Alcohol Detergente suave Agua Agua 50 Este tipo de masaje emula a los pulgares de ambas manos que trabajan sobre los puntos de acupresión Se trata de una alternancia de presión y relajación que transmite la misma sensación que un masajista de shiatsu profesional Este tipo de masajes resulta ideal para aquellas personas con fatiga y dolores musculares que necesitan un masaje localizado Shiat...

Page 28: ... puntos de verificación o si los remedios indicados en la tabla no solucionan el problema llámenos al 1 800 338 0552 para localizar el centro de servicio más próximo a usted Problema Causa y solución No hay respuesta al pulsar el botón de reclinación Cuando se retrae el respaldo por motivos de seguridad los rodillos de masaje se desplazan hacia la posición de recogida antes de que el respaldo comi...

Page 29: ...3 6 31 5 65in 60 80 165cm Peso 128 lbs 58 kg Peso máximo del usuario 264 lbs 120 kg DATOS TÉCNICOS EP1061 Alimentación 120V AC 60Hz Consumo de energía 135W Aprox 5W en modo de espera con el mando de control apagado o cuando la unidad está apagada Masaje de la parte superior del cuerpo Área de masaje Arriba Abajo 27 6in 70 cm aprox Área de masaje Izquierda Derecha Distancia entre los rodillos de ma...