11 Cord arrangement of the connecting
cord for power /supply and the
connecting cord for controller.
*The two types of wires are to be arranged with the massage block set in its upper most position (in
respect to the chair).
1. Connect the two connectors, (a) and (c) to Main PCB.
2. Install the ground wires (d).
3. Fix the Cord wire for chair side on the Back frame.
4. Grasp white mark on the Connecting cord for power supply by large cable tie and then fix them
on the Back frame.
5. Bind two cords with two lead wires of massage clutch and up/down sensor by using a small cable
tie.
6. Bind seven wires of intensity clutch, up/down clutch, massage clutch, transformer, intensity
sensor, up/down sensor and capacitor by using a middle cable tie.
7. Bind six wires of intensity clutch, up/down clutch, massage clutch, transformer, intensity sensor
and up/down sensor by using a middle cable tie.
8. Bind four wires of massage position sensor, tapping clutch, intensity sensor and up/down sensor
by using a middle cable tie.
9. Set three cables through the cord guide frame and set the cord fitting as shown figure.
10. Bind three cables at end of the cord guide frame and center of main circuit board with another two
wires.
11. Wind three cords around the Cord wire for chair side one and half times and bind them together
using a small cable tie.