EJ (AEJ)

2. Specifications

Notes: *1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the 

actual load.

*2 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. 

Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT .

*3 Condition: Nominal switching 100cycles, each cut off 800A
*4 When using a surge absorbing element for the relay coil drive circuit, please use with a surge absorbing element with a clamp voltage of 1.5 to 2.0 times the rated 

operating voltage. When the coil is connected in parallel with a diode, resistor or capacitor, the release time will delay which might lead to degradation in shutoff 
performance and electrical life.Contact terminals have polarity; therefore, please obey the wiring diagram when connecting contacts.The electrical load 
performance value applies when a varistor is connected in parallel with the coil.

REFERENCE DATA

Characteristics

Item

Specifications

Rating

Arrangement

1 Form A

Contact voltage drop (Initial)

Max. 0.15V (at 100A)

Contact material

AgCuO type

Nominal switching capacity (resistive load)

100A 100V DC

Max. carrying current/short time carrying current

1,000A (0.1s)

Min. switching capacity (Reference value)*

1

1A 12V DC

Max. cut-off current

800A 100V DC/3 cycle*

3

Overload opening rating

300A 150V DC/10 cycle

Electrical 
characteristics

Insulation resistance (Initial)

Min. 100M

 (at 500V DC) 

Measurement at same location as “Initial breakdown voltage” section.

Breakdown voltage 
(Initial)

Between open contacts

1,500 Vrms for 1min. (Detection current: 10mA.)

Between contact and coil

2,500 Vrms for 1min. (Detection current: 10mA.)

Operate time (at 20

°

68

°

F

)

Max. 30ms (Nominal voltage applied to the coil, excluding contact bounce time)

Release time (at 20

°

68

°

F

)

Max. 15ms (Nominal voltage applied to the coil)

Mechanical 
characteristics

Shock resistance

Functional

Min. 500 m/s

2

 (Nominal voltage applied to the coil)

Min. 50 m/s

2

 (deenergized) (Half-wave pulse of sine wave: 11 ms; detection time: 10

µ

s.)

Destructive

Min. 1000 m/s

2

 (Nominal voltage applied to the coil or deenergized.) 

(Half-wave pulse of sine wave: 6 ms)

Vibration resistance

Functional

10 to 200Hz, 44.1m/s

2

 (Nominal voltage applied to the coil or deenergized)

Destructive

10 to 200Hz, 44.1m/s

2

 (Nominal voltage applied to the coil or deenergized)

(Time of vibration for each direction; X, Y, Z direction: 4 hours)

Expected life

Mechanical

Min. 10

6

Electrical

Min. 10

4

 (at 100A 100V DC) 

(Resistive load, operating frequency 1s ON, 9s OFF, room temperature)

Conditions

Conditions for operation, transport and storage*

2

Ambient temperature: –40

°

C to +85

°

–40

°

F to +185

°

F

Unit weight

Approx. 300g 

10.58oz

1. Maximum value for switching capacity

2. Carrying current limit

Connection electric wire: 40mm

2

Ambient temperature: 85

°

185

°

F

Standard for judgment: Relay contacts off when 
carrying finished.

Carrying current and  carrying time

1,000

100

10

10

100

1,000

Contact voltage, V

Contact current, A

DC resistive load

0.1

1

10

10000

1000

100

0

200

400

600

800

1000 1200

Carrying current, A

Carrying time, s

3. Distribution of pick-up and drop-out voltages

Tested sample: AEJ11012, 50 pcs.

4. Distribution of operate time

Tested sample: AEJ11012, 50 pcs.

5. Distribution of release time

Tested sample: AEJ11012, 50 pcs.

0

15

10

5

20

25

3.0

2.0

1.5

1.0

2.5

3.5

4.5 5.0

4.0

5.5 6.0

7.0

6.5

Pick-up
voltage

Drop-out
voltage

)

(20

°

C

68

°

F

Voltage, V

Quantity

0

5

10

15

20

13.0

11.0

10.0

12.0

14.0

16.0 17.0

15.0

18.0 19.0 20.0

Time, ms

Quantity

)

(20

°

C

68

°

F

0

5

10

15

25

20

1.5

0.5

0.0

1.0

2.0

3.0 3.5

2.5

4.0 4.5 5.0

Time, ms

Quantity

)

(20

°

C

68

°

F

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Summary of Contents for EJ Relays

Page 1: ...ctive compatibility information http www mew co jp ac e environment FEATURES 1 Compact and high capacity using double contacts in series and permanent magnet installed 1 Nominal switching capacity resistive load 100A 100V DC Min 104 2 Max cut off current 800A 100V DC 2 Compact and lightweight for space savings 70mm L 80mm W 34mm H 2 756inch L 3 150inch W 1 339inch H 3 Environmentally friendly In c...

Page 2: ...Operate time at 20 C 68 F Max 30ms Nominal voltage applied to the coil excluding contact bounce time Release time at 20 C 68 F Max 15ms Nominal voltage applied to the coil Mechanical characteristics Shock resistance Functional Min 500 m s2 Nominal voltage applied to the coil Min 50 m s2 deenergized Half wave pulse of sine wave 11 ms detection time 10µs Destructive Min 1000 m s2 Nominal voltage app...

Page 3: ...34 0 039 020 1 339 1 0 0 5 33 6 039 020 1 323 2 5 3 dia 2 209 dia 0 3 0 1 012 004 2 M 236 11 811 787 2 811 2 299 1 417 146 146 2 047 2 598 012 3 150 1 063 2 756 1 240 1 476 591 394 Notes 1 Please be warned that contact terminals have polarity There is no polarity in the coil input line 2 We will make separate consideration if a coil lead wire connector is desired Schematic Top view Mounting hole p...

Page 4: ...increase due to a rise in the coil temperature This causes the pick up voltage to rise and possibly exceed the rated pick up voltage In these circumstances take measures such as reducing the load current limiting the duration of current flow and applying a coil voltage higher than the rated operating voltage quick start 10 If you are using an inductive load L load such that L R 1 ms add surge prot...

Reviews: