TEST AND MEASUREMENT
MCUK000601C8
Section 6
Issue 1
Service Manual
– 45 –
Revision 0
Figure 6.19: RSSI dB field
6.
If the measured power is not -90 ±1, then make the following calculation:
RSSI offset value
= [-(90 + MEASURED RSSI VALUE)] x 2
=[ -90 - MEASURED RSSI VALUE] x 2,
for example
[-(90 + (95))] x 2
= [-90 - (-95)] x 2
= 10
Record the result.
7.
At the channelbox, press F7 to view data.
Figure 6.20: RSSI reading 1
8.
Select TRIM OTHER and make a note of the RSSI COMP GSM reading.