TEST AND MEASUREMENT
Issue 1
Section 6
MCUK000601C8
Revision 0
– 46 –
Service Manual
Figure 6.21: RSSI reading 2
9.
Press ESC.
10. At the Channel box, press F6 to program data.
Figure 6.22: RSSI reading 3
11. Select TRIM RSSI and press ENTER.
12. Highlight RSSI Mch GSM and press ENTER.
13. Make the following calculation:
RSSI Offset Value (step 8) + reading noted in step 6.
Enter the result in to the RSSI Mch field.
14. Press ENTER.
15. Press ESC.
16. Measure the RSSI level again by highlighting the RSSI dBm field again and press ENTER.