After making repairs, we recommend performing the following
inspection, to check normal operation.
10.2. Notice after replacing Digital P.C.B.
[TM L1] is displayed after replacing Digital P.C.B.
Once power off, and start up again.
10.3. When the unit does not operate normally after replacing the Timer
Microprocessor or Main P.C.B.
When the unit does not operate normally after replacing the Timer Microprocessor or Main P.C.B. with new one, reset Timer
Microprocessor.
Step
Operation
Descriptions
1
While power is ON, short TL7507 (RESET) and the TL7506 (GND)
momentarily.
“RESET (L)” is transmitted to the X-REST of Timer
Microprocessor (IC7501-8 pin), then the unit operates
normally.