52
10 Measurements and Adjustments
10.1. Introduction
When servicing this unit, make sure to perform the adjustments necessary based on the part (s) replaced.
Before disassembling the unit, it is recommended to back up the camera data stored in Flash-ROM as a data file.
NOTE: (When replacing the Lens unit, Master Flange Unit and MOS Unit)
• When the MOS Unit is unavoidably removed for Lens Unit, Master Flange Unit and MOS Unit replaced, an optical tilt adjustment
is necessary after parts are exchanged.
• The adjustment software (DSC_Tilt) is necessary to execute an optical tilt adjustment.
• The adjustment software "DSC_Tilt" is available at "TSN Website".
NOTE: (When replacing the Main P.C.B.)
• Number of necessary adjustment items decreases by copying the backup data to new Main P.C.B. when adjustment data in old
Main P.C.B. can be read by ROM_BACKUP "DSC
SD" in "10.2.2. Flash-ROM Data Backup".
For more details, please refer an item "Main P.C.B. (to which the backup data was copied)" in the table of "10.3.2. Adjustment
Specifications".
10.2. Before Disassembling the unit
10.2.1. Initial Setting Release
The cameras specification are initially set in accordance with model suffix (such as EB/EG/GN and so on.).
Unless the initial setting is not released, an automatic alignment software in the camera is not able to be executed when the
alignment is carried out.
Note:
The initial setting should be again done after completing the alignment. Otherwise, the camera may not work properly.
Therefore as a warning, the camera display a warning symbol " ! " on the LCD monitor every time the camera is turned off.
Refer to the procedure described in "3.5.2. Initial Settings" for details.
[ How to Release the camera initial setting ]
• Preparation:
Attach the fully charged Battery, and insert the memory card (32MB or more).
Remove the lens cap.
•
Step 1. The temporary cancellation of "Initial Settings":
Set the [ Mode dial ] to "[ P ](Program AE mode)".
While pressing [ DISP. ] button, "[ RIGHT ] of Cursor buttons" and [ AF/AE LOCK ] button simultaneously, turn the power on.
•
Step 2. The cancellation of "Initial Settings":
Press the [ Playback ] button in order to enter the [ Playback ] mode.
Press [ AF/AE LOCK ] button and "[ UP ] of Cursor buttons" simultaneously, then turn the power off.
The LCD displays the " ! " mark before the unit powers down.
Summary of Contents for DMC-FZ300PP
Page 17: ...17 ...
Page 18: ...18 ...
Page 20: ...20 ...
Page 29: ...29 9 3 1 Removal of the Rear Case Unit Fig D1 Fig D2 ...
Page 30: ...30 Fig D3 Fig D4 ...
Page 31: ...31 Fig D5 9 3 2 Removal of the Main P C B Fig D6 ...
Page 32: ...32 Fig D7 9 3 3 Removal of the Top Case Unit and Battery Case Unit Fig D8 ...
Page 33: ...33 Fig D9 Fig D10 ...
Page 34: ...34 Fig D11 Fig D12 ...
Page 37: ...37 Fig D18 Fig D19 ...
Page 40: ...40 9 3 13 Removal of the LCD IF P C B MR Sensor FPC and LCD Unit Fig D24 Fig D25 ...
Page 43: ...43 9 4 3 Removal of the Zoom Motor 1 Unscrew the 2 screws C ...
Page 58: ...58 ...
Page 59: ...59 ...
Page 60: ...60 ...
Page 64: ...64 ...