EN10

  Unscrew the cord holder and fi x the cable. Strip the cable (coating).

Loosen the screw and fasten the live wire (L)  and neutral wire (N) to the ELB (L,N); insert the earth wire 
under the Earth Plate to the Ground Point with 1 N.m (10 k

g

f.cm) torque. Fix back the cord holder to its 

position to clamp the cable.

5 mm

L

N

ELB Terminal

Ground Point

1 N.m

40 mm

13 mm

50 mm

13 mm

L
N

  Connect wires in correct polarity (L,N).

• Connecting wires in wrong polarity (L,N) causes an abnormal condition which may lead to electric leaking, burning, 

and such.

• Before wiring, please check polarity (L,N) with voltage range of a tester or voltmeter by connecting one terminal of 

the tester to earth while the other to one of the Power Supply terminal.

• When the needle of the tester defl ects greatly, the polarity of the Power Supply terminal is "L".

Main Power Board

Power-Supply 
Terminals

Tester

Earth

 Earth 

Rod.

 

WARNING

The appliance must be earthed. Improper grounding could 
cause electric shock.

• Earth Rod handling procedure. Select adapter place to bury the optional Earth Rod (DQ-6H) for at least 70 cm 

below ground surface.

• Ensure that the ground resistance is less than 100 

 . If it is not, drive the Rod deeper into ground surface or use 2 

or 3 Rods.

Ground
Surface

Burying tool

Earth Rod

70 cm at least

70 cm at least

(Bevel Style)

(Parallel Style)

70 cm at least

About 2 m About 2 m

Connection

Connection

1 m

5. Piping installation procedure.

Note:

•  Make sure no water leaks from pipe connection.
•  When glue is used for external piping connection, must wait for the glue to dry before proceeded to test run with 

water.

 

WARNING

Do not share the inlet pipe of the appliance with other outlets. 
The pressure may drop due to water being drawn off at other 
point. The water temperature may become very hot.

Earth Plate

DH-6SM1_TH.indb   10

DH-6SM1_TH.indb   10

14/7/2020   7:52:21 PM

14/7/2020   7:52:21 PM

Summary of Contents for DH-6SM1

Page 1: ...น TH11 บัตรรับประกัน หน าสุดท าย Operating and Installation Instructions Electric Water Heater Household Use English Thank you for purchasing this Panasonic product Please read these instructions carefully in order to use this product correctly and safely Before using this product please give your special attention to the SAFETY PRECAUTIONS Please keep this Operating and Installation Instructions ...

Page 2: ...our Service Centre for repairing This appliance is not to be used for a potable water supply The appliance must be earthed Improper grounding could cause electric shock Stop using the appliance when any abnormality failure occurs and switch off the Miniature Circuit Breaker MCB Risk of smoke fire electric shock scalding Example of abnormality or failure The ELB Reset Lever cannot be reset Please r...

Page 3: ...o avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility Do not switch on if there is possibility the water in the appliance is frozen Never fix the appliance forcibly with tape or adhesives Strictly follow all the instr...

Page 4: ...aucet Hot Water Faucet Faucet Temperature Control Knob ELB Lamp Front Plate Filter Knob O Ring Filter Unit Water Outlet Note It is recommended to make the cold water and hot water mixing piping as illustrated ACCESSORIES Description Items Ø6 25 mm M4 1 25 mm Installation Packing Wall Plug 4 pcs Screw 4 pcs Note When removing the appliance from package some water may be found inside This is normal ...

Page 5: ...FILTER CLEANING FILTER CLEANING FILTER CLEANING Push ELB On condition ELB Off condition Set the Temperature Control Knob to the desired position a When the Temperature Control Knob is set to Min temperature level is low b When the Temperature Control Knob is set to Max temperature level is high Turn on the Hot Water Faucet The ELB Lamp will light up once the appliance operates Min Max ELB CAUTION ...

Page 6: ...nce Check whether the water and electrical connections comply with the Specifications as indicated Make sure to switch on the ON OFF DP Double Pole Switch Make sure to switch on the Miniature Circuit Breaker MCB Make sure the ELB Reset Lever is not slide down Push up the ELB Reset Lever to reset the ELB refer to TEST OPERATION at page EN11 No water flows out from the appliance at all Make sure the...

Page 7: ...permanently connected to the electric supply through the ON OFF DP double pole Switch having a contact separation of at least 3 mm in all poles incorporated in the fixed wiring This switch must be clearly identifiable but out of reach of a person using a fixed bath or shower Use the attached accessories parts for installation CAUTION This appliance must be installed indoor only Flexible Cord must ...

Page 8: ...d at the place where water existence will lead to smoke emission ignition fire electric shock and damage to property 2 How to remove the Front Plate Make sure the Temperature Control Knob at Min position Remove the Screw at the bottom of the appliance Lift up the Temperature Control Knob to make it free Make sure the Temperature Control Knob is not detached from the Front Plate Remove the Front Pl...

Page 9: ...set fixed tightly on the wall by shaking it left and right Note The Back Plate must be mounted with 4 Screws Wall Back Plate Wall Plug Back Plate Wall Plug Wall 4 Electric wiring Make sure rated electrical supply is supplied to this appliance WARNING Proper size of Flexible Cord and electric wiring must be installed to avoid smoke emission and fire hazards The appliance must be permanently connect...

Page 10: ...r Board Power Supply Terminals Tester Earth Earth Rod WARNING The appliance must be earthed Improper grounding could cause electric shock Earth Rod handling procedure Select adapter place to bury the optional Earth Rod DQ 6H for at least 70 cm below ground surface Ensure that the ground resistance is less than 100 If it is not drive the Rod deeper into ground surface or use 2 or 3 Rods Ground Surf...

Page 11: ...ront Plate OFF position FILTER CLEANING D Cut Position Back Plate Front Plate Back Plate Screw Front Plate Press TEST OPERATION WARNING Inspect the built in ELB once a month to avoid a hazard to users such as damage to property serious injury or death If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down during operation do not use the appliance and contact an aut...

Page 12: ...อดแยก ซ อมแซม หรือดัดแปลงตัวเครือง ซึงอาจทําให เกิดไฟไหม ไฟฟ าช อต หรือการบาดเจ บได โปรดติดต อศูนย บริการของคุณเพือทําการซ อมแซม ห ามใช เครืองนีกับแหล งจ ายนําแบบพกพา เครืองนีต องต อลงดิน การติดตังสายดินเพือป องกันไฟฟ าดูด ไฟฟ าช อต หยุดใช เครืองนีหากเกิดสิงผิดปกติ การทํางานล มเหลว และให ปิดสวิตช เบรคเกอร สะพานไฟ ความเสียงจากควันไฟ ไฟไหม ไฟฟ าช อต นําร อนลวก ตัวอย างความผิดปกติหรือการทํางานล มเหลว...

Page 13: ...ขนหนู หรือบิดสายฝักบัว ไม ได มากับตัวเครือง อัตราการไหลของนําจะลดลง และอุณหภูมิของนําอาจจะร อนจัด เพือหลีกเลียงอันตรายทีอาจเกิดขึนจากการรีเซ ตตัวของเครืองตัดกระแส ไฟโดยไม ตังใจ เครืองตัดกระแส ไฟฟ าไม สามารถถูกจ ายจากสวิชต ภายนอกได เช น ตัวตังเวลา หรือ เชือมต อกับวงจรเปิด ปิดแบบอัตโนมัติ อย าเปิดสวิตช หากสงสัยว านําทีอยู ในเครืองอาจแข งตัว อย าซ อมเครืองด วยการปิดเทปหรือกาว ปฏิบัติตามคําแนะนําในการ...

Page 14: ...แยกซือต างหาก ปุ มเปิดนําเย น ก อกนําร อน ก อกนํา ลูกบิดควบคุมอุณหภูมิ ไฟ ELB ฝาครอบหน า ปุ มเครืองกรองนํา วงแหวนรูปโอ ชุดกรองนํา ทางนําออก หมายเหตุ ให เดินท อนําเย นและท อนําร อนผสมกันตามรูป อุปกรณ เสริม คําอธิบาย รายการ Ø6 25 มม M4 1 25 มม การติดตังการบรรจุ ปลักผนัง 4 ตัว ถอดสกรู 4 ตัว หมายเหตุ ขณะถอดเครืองออกจากหีบห อ อาจพบนําอยู ภายในบ าง ซึงถือว าเป นปกติเนืองจากจะมีการทดสอบเครืองในระหว างการ...

Page 15: ...R CLEANING ดัน ELB เปิด ELB ปิด ตังค าลูกบิดควบคุมอุณหภูมิให อยู ในตําแหน งตามทีต องการ a หากตังค าลูกบิดควบคุมอุณหภูมิเป น Min ตําสุด อุณหภูมิจะอยู ในระดับตํา b หากตังค าลูกบิดควบคุมอุณหภูมิเป น Max สูงสุด อุณหภูมิจะอยู ในระดับสูง หมุนลูกบิดเพือเลือกกําลังไฟฟ า ไฟ ELB จะสว างขณะทีเครืองกําลังทํางาน Min Max ELB ระวัง หลีกเลียงการใช นําสกปรกซึงอาจส งผลกระทบต อ ประสิทธิภาพ การทํางานของเครืองทําความร...

Page 16: ...และไฟฟ าสอดคล องกับข อมูลจําเพาะทีระบุไว หรือไม ตรวจสอบให แน ใจว า สวิตช เปิด ปิด การทํางาน ขัวคู เปิดอยู ตรวจสอบให แน ใจว า เบรคเกอร ตัดวงจรขนาดเล ก MCB เปิดอยู ตรวจสอบให แน ใจว า แกน ELB ไม ได เลือนลง ดันแกน ELB ขึนเพือตังค า ELB ใหม อีกครัง โปรดดู ทดสอบการทํางาน หน า TH11 ไม มีนําไหลออกมากจากเครืองเลย โปรดแน ใจว าท อจ ายนําเข าเปิดอยู ตรวจสอบดูว ามีท อจ ายนําอยู หรือไม ตรวจสอบดูว าท อจ ายนําเข ...

Page 17: ...เกิดขึนจากการเกิดควันไฟและไฟไหม เครืองนีจะต องเชือมต อกับแหล งจ ายไฟแบบถาวรผ านสวิตช เปิด ปิด การทํางานทีมีระยะห างหน าสัมผัสของทุก ขัวทีอยู ในระบบสายไฟแบบคงทีอย างน อย 3 มม จะต องจําแนกสวิตช นีออกมาได อย างเด นชัด แต ต องอยู สูงเกิน กว าบุคคลทีใช อ างอาบนําหรือฝักบัวจะเอือมถึง ใช อะไหล เสริมทีให มาเพือทําการติดตัง ระวัง เครืองนีจะต องใช สําหรับการติดตังในร มเท านัน ต องใส สายท ออ อนเข าไปในเครือง...

Page 18: ...ด ควัน ประกายไฟ ไฟไหม ไฟฟ าช อต และเกิดความเสียหายต อ ทรัพย สิน 2 วิธีการถอดฝาครอบหน า โปรดแน ใจว าลูกบิดควบคุมอุณหภูมิอยู ทีตําแหน ง Min ตําสุด ถอดสกรูทีด านล างของเครืองออก ดันปุ มปรับอุณหภูมิขึน ปุ มปรับอุณหภูมิติดกับ ฝาปิดปุ มไฟฟ า ในเครือง ให แน ใจว าปุ มปรับอุณหภูมิไม ติดไปกับฝาครอบ ดึงฝาครอบด านล างก อนแล วปลดขอเกียวด านบนออก ถอดฝาครอบรูปตัว U ออกจากเครืองก อนทําการติดตัง หมายเหตุ ลูกบิดควบ...

Page 19: ...เขย าเครืองซ ายขวา หมายเหตุ ในการติดตังเครืองต องใช สกรู 4 ตัว ผนัง แผ นหลัง ปลักผนัง แผ นหลัง ปลักผนัง ผนัง 4 การต อสายไฟ โปรดแน ใจว ามีแหล งจ ายไฟสําหรับตัวเครืองนีตามทีระบุไว คําเตือน ในการติดตังเครืองทํานําร อนขนาดของสายท ออ อนและสายไฟต อง มีขนาดทีเหมาะสม เพือหลีกเลียง อันตรายทีเกิดขึนจากการเกิด ควันไฟและไฟไหม เครืองนีจะต องเชือมต อกับแหล งจ ายไฟแบบถาวรผ านสวิตช เปิด ปิด การทํางานทีมีระยะห างห...

Page 20: ...องแหล งจ ายไฟ มิเตอร ทดสอบ สายดิน การต อสายดิน คําเตือน เครืองนีต องต อลงดิน การติดตังสายดินเพือป องกันไฟฟ าดูด ไฟฟ า ช อต โปรดเลือกสถานทีทีฝังแท งกราวด DQ 6H ในทีชืน และฝังลึกลงไปโดยส วนบนสุดจะต องลึกจากผิวดินอย างน อย 70 เซนติเมตร ค าความต านทานทีวัดได ต องน อยกว า 100 Ω หากว าวัดได มากกว าจะต องกดแท งกราวด ให ลึกลงไปอีกหรือพิมแท งกราวด เป น 2 หรือ 3 แท ง ผิวดิน เครืองมือสําหรับใช ฝัง แท งสายดิน...

Page 21: ... ตําแหน งปิด FILTER CLEANING ตําแหน ง D Cut แผ นหลัง ฝาครอบหน า แผ นหลัง ถอดสกรู ฝาครอบหน า กด ทดสอบการทํางาน คําเตือน ตรวจสอบ ELB ทีมากับเครือง เดือนละครัง เพือหลีกเลียงอันตราย ต างๆ ทีอาจเกิดขึนกับผู ใช เช น ทรัพย สินได รับความเสียหาย การ บาดเจ บร ายแรง หรือการเสียชีวิต หากแกนสวิตช นิรภัย ELB ไม สามารถทําการรีเซ ตได แม ว าคุณจะ ดันขึนแล ว หรือปุ มนีเลือนกลับลงมาขณะดําเนินการ โปรดอย าใช เครืองและ...

Page 22: ...Memo DH 6SM1_TH indb 12 DH 6SM1_TH indb 12 14 7 2020 7 52 30 PM 14 7 2020 7 52 30 PM ...

Page 23: ...Memo DH 6SM1_TH indb 13 DH 6SM1_TH indb 13 14 7 2020 7 52 30 PM 14 7 2020 7 52 30 PM ...

Page 24: ...Memo DH 6SM1_TH indb 14 DH 6SM1_TH indb 14 14 7 2020 7 52 30 PM 14 7 2020 7 52 30 PM ...

Page 25: ...DH 6SM1_TH indb 15 DH 6SM1_TH indb 15 14 7 2020 7 52 30 PM 14 7 2020 7 52 30 PM ...

Page 26: ...asonic co th Panasonic A P Sales Thailand Co Ltd Panasonic Manufacturing Malaysia Berhad 196501000304 F0820Y0 Printed in Malaysia DH 6SM1_TH indb 16 DH 6SM1_TH indb 16 14 7 2020 7 52 31 PM 14 7 2020 7 52 31 PM ...

Page 27: ...DH 6SM1_TH indb 17 DH 6SM1_TH indb 17 14 7 2020 7 52 32 PM 14 7 2020 7 52 32 PM ...

Page 28: ...Download English version DH 6SM1_TH indb 18 DH 6SM1_TH indb 18 14 7 2020 7 52 32 PM 14 7 2020 7 52 32 PM ...

Reviews: