EN11
English
FILTER
CLEANING
Filter Body
Assembly
ELB Reset
Lever
Main Water
Valve
Water Inlet
FILTER
CLEANING
Main Body
Thread
End
Water
Outlet
Use Flexible Pipe
Minimum length
150 mm
Tee Joint
Main Water
Valve
Parts not
included
(1)
Rubber
Packing
(2)
(1) Tee joint must be installed between the
Main Water Valve and Flexible Pipe.
(2) Place Rubber Packing between Filter
Body Assembly and Flexible Pipe.
Do not use Piping Tape. Tighten it by
spanner fi rmly.
Remark:
It is desirable to make the piping as short
and linear as possible because the longer
the distance from the appliance to the
Faucet, greater infl uence may be caused
on the hot water temperature due to
increase in resistance and change in water
temperature.
6. How to fi x the Front Plate.
Make sure the Temperature Control Knob on
Front Plate and "D-Cut" at "Min" position.
Close the Front Plate of the appliance
according to the sequence as illustrated
(Close from top to bottom).
Press the Temperature Control Knob.
Fix the Screw at the bottom of the appliance.
Note:
• Do not push the ELB Test Button when fi xing
the Front Plate.
LET
OUTLE
T
ELB
ELB T
est
EL
B Reset
Push U
p
Min
Max
ELB
ELB Test
ELB Reset
Push Up
Max
Min
FILTER
CLEANING
ELB
ELB Test
ELB Reset
Push Up
Max
Min
FILTER
CLEANING
Min
Max
ELB
ELB Test
ELB Reset
Push Up
FILTER
CLEANING
FILTER
CLEANING
Front Plate
OFF position
FILTER
CLEANING
"D-Cut" Position
Back Plate
Front Plate
Back
Plate
Screw
Front Plate
Press
TEST OPERATION
WARNING
●
Inspect the built-in ELB (once a month) to avoid a hazard to
users such as damage to property, serious injury or death.
●
If the ELB Reset Lever cannot be reset even if you push it
up or if it soon slides down during operation, do not use the
appliance and contact an authorized dealer immediately to
avoid a hazard to users such as damage to property, serious
injury or death. Never fi x the ELB Reset Lever forcibly with
tape and such.
1.
• Turn on the Main Water Valve.
• Check if water leaks from the Pipe Line.
2.
• Before switch on electricity check the wiring.
• Switch on the Miniature Circuit Breaker (MCB) and the ON/OFF DP (Double Pole) Switch.
• ELB Lamp (red) will light up. (Push up the ELB Reset Lever if it is down)
• Push the ELB Test Button.
- It is normal if the ELB Lamp goes off (the ELB Reset Lever falls) and
push the ELB Reset Lever up.
3.
• Open the Hot Water Faucet and set the temperature by turning the Temperature
Control Knob.
• Set the Temperature Control Knob between "Min" to "Max".
4.
• Regulate the Hot Water Faucet so that the hot water temperature becomes optimum.
• Too hot
: Further open the Cold Water Faucet.
: Check for clogging of the piping.
• Too cold : Reduce the volume of water from the Cold Water Faucet or further open the Hot Water Faucet.
Min
Max
ELB
ELB Test
ELB Reset
Push Up
FILTER
CLEANING
FILTER
CLEANING
Push
DH-6SM1_TH.indb 11
DH-6SM1_TH.indb 11
14/7/2020 7:52:22 PM
14/7/2020 7:52:22 PM
Summary of Contents for DH-6SM1
Page 22: ...Memo DH 6SM1_TH indb 12 DH 6SM1_TH indb 12 14 7 2020 7 52 30 PM 14 7 2020 7 52 30 PM ...
Page 23: ...Memo DH 6SM1_TH indb 13 DH 6SM1_TH indb 13 14 7 2020 7 52 30 PM 14 7 2020 7 52 30 PM ...
Page 24: ...Memo DH 6SM1_TH indb 14 DH 6SM1_TH indb 14 14 7 2020 7 52 30 PM 14 7 2020 7 52 30 PM ...
Page 25: ...DH 6SM1_TH indb 15 DH 6SM1_TH indb 15 14 7 2020 7 52 30 PM 14 7 2020 7 52 30 PM ...
Page 27: ...DH 6SM1_TH indb 17 DH 6SM1_TH indb 17 14 7 2020 7 52 32 PM 14 7 2020 7 52 32 PM ...