ELB
Po
wer Control
Mai
n Switch
ELB
Off
Off
High
On
High
On
- 8 -
Note: When removing the Unit from package, some water may be found inside.
This is normal as the Unit is tested during the manufacturing process.
2. HOW TO INSTALL
(1) Make sure water flow pressure.
Min. water pressure
9.8 kPa / 0.1 k
g
f/cm² / 1.42 psi
Max. water pressure
380 kPa / 3.87 k
g
f/cm² / 55 psi
• How to measure the water pressure as illustrated. Water should flow out of the
Hose 2.0 m above the Main Water Valve.
1. BEFORE INSTALLATION
2.0 m
HOW TO INSTALL ELECTRIC HOME SHOWER
1. Where to install the Unit.
• Be sure to install the Unit on the wall as illustrated in Figure 1
(vertical position with the water fittings pointing downward).
• Do not install the Unit away from wall surface as shown in Figure 2.
• The Unit must be installed at 1.5 m - 1.7 m above the floor.
Figure 1
Figure 2
Flexible Cord must enter the Unit thru designated point only (do not make additional holes).
• Proper size of Flexible Cord and electric wiring must be installed to avoid smoke emission and fire hazards.
• During installation process make sure electric and water supply is turn "OFF".
• The home shower must be permanently connected to the electric supply through the ON/OFF DP (double
pole) Switch having a contact separation of at least 3 mm in all poles incorporated in the fixed wiring. This
switch must be clearly identifiable but out of reach of a person using a fixed bath or shower.
The Unit must be earthed.
Improper grounding could cause electric shock.
• Never install Filter Body Assembly at the outlet, inlet water cannot be filtered and allows
foreign particles to enter the Unit. It will cause Heater Unit and Shower Head to clog up.
• Do not install, remove and reinstall the Unit by yourself.
Improper installation will cause leakage, electric shock or fire. Installation and wiring must be
done by competent personnel.
• Do not share the inlet and outlet pipe of the Home Shower Unit with other outlets.
The pressure may drop due to water being drawn off at other point. The shower temperature
may become very hot.
WARNING
CAUTION
During installation process make sure electric and
water supply is turn "OFF".
WARNING
1.5 m - 1.7 m
2. How to remove the Front Plate
①
Make sure the Main Switch Knob and Power Control Knob
are at “Off” condition.
②
Remove the screw at the bottom of the Unit.
③
Lift up the Main Switch Knob to make it free (Main Switch
Knob is attached to Rotary Shaft inside the Unit. Do not
fully detach the Main Switch Knob from the Front Plate).
Make sure the Main Switch Knob and Power Control Knob
are not detached from the Front Plate.
④
Remove the Front Plate by lifting up Main Switch Knob and
then unhook the top side (Main Switch Knob shall not detach
from Front Plate).
Screw
Front
Plate
Note:
Main Switch Knob and Power Control Knob are attached to Front Plate.
Do not remove Main Switch Knob and Power Control Knob from Front Plate.
Main Switch Knob
and Power Control Knob
Main
Switch Knob
Power
Control Knob
Lift up
①
②
④
③
Water Inlet
Water
Outlet
Filter Body
Assembly
L N
WA
RNING
MU
ST
B
E
TI
GHT
ENED
1
N
•m
ELB
ELB Test
ELB Reset
Push Up
Pow
er Control
Mai
n Switch
ELB
Off
Off
High
On
ELB Test
ELB Reset
Push Up
OP
EN
CL
O
SE
FILTER
CLEANING
ELB Test
ELB Reset
Push Up
OFF
MAX
Pow
er Contr
ol
Main Switch
ELB
Off
Off
High
On