background image

OP

EN

CL

O

SE

FILTER
CLEANING

ELB Test

ELB Reset

Push Up

OFF

MAX

Pow

er Contr

ol

Main Switch

ELB

Off

Off

High

On

OP

EN

CL

O

SE

FILTER
CLEANING

ELB Test

ELB Reset

Push Up

OFF

MAX

Pow

er Contr

ol

Main Switch

ELB

Off

Off

High

On

- 3 -

Stop using the Unit when any abnormality/failure occurs and turn "OFF" the 

Miniature Circuit Breaker (MCB). (Risk of smoke/fire/electric shock/scalding)

 

• The ELB Reset Lever cannot be reset. Please refer to item no. 3. TEST OPERATION at page 11.

 

• Burnt odor or smoke is detected during operation.

 

• The Front Plate/Back Plate is deformed or abnormally hot.

 

• The outlet water temperature become extremely hot and cannot be controlled using the Power Control Knob.

Contact your authorized dealer immediately for maintenance/repair.

Example of 

abnormality/

failure

WARNING

CAUTION

BEFORE USING

•  Do not spray water to the Unit, nor 

  put wet towels on it to avoid from 

  coming into contact with any live 

  parts and such, in order to prevent 

  smoke emission, ignition, fire and 

  electric shock hazards.

•  Switch off the Miniature Circuit Breaker (MCB) before

  any service to avoid electric shock hazards.

• Pay attention to the shower temperature when 

  reducing the volume of water. 

 

The shower temperature will become very hot if the 

  water flow rate is too low.

•  When the shower is used by someone such as child, old 

  person, sick person and physically handicapped person, 

  the person responsible for their safety

  is kindly requested to pay attention 

  and check the shower temperature by 

  using hand from time to time.

•  In time of lightning / thunder, switch “OFF” the 

 Miniature Circuit Breaker (MCB) in advance to protect 

  the shower Unit against possible damage.
•  Inspect on the built-in ELB (once a month) to avoid a 

  hazard to users such as damage to property, serious 

  injury or death. Please refer to item no. 3. TEST 

  OPERATION at page 11.

• 

The Unit must be earthed.

 

Improper grounding could cause electric shock.

• Do not insert finger or other objects into the electric 

  home shower Unit to avoid physical and electric 

  shock hazards.

•  If the ELB Reset Lever cannot be reset even if you push it

  up or if it soon slides down during operation, please do

  not use the Unit and contact the authorized dealer

  immediately to avoid a hazard to users such as damage

  to property, serious injury or death. Never fix the ELB

  Reset Lever forcibly with tape and such. 

• Do not replace the Shower Head, Shower Hose or any 

  other parts of the Unit with spare parts other than 

  genuine parts.

  Parts for other models will not

  fit to this model and may cause 

  hazardous condition to user. 

Shower Hose

Shower Head

THINNER

• Never use benzene, thinner, bleaching  

  agent and such for cleaning purpose to 

  avoid smoke emission, ignition, fire and 

  electric shock hazards.

• Please make sure the O Ring is  

  not removed and shall be free  

  from foreign particle to avoid  

  water leaking. 

• Avoid using dirty water as it may affect heater 

  performance and other components.

•  This appliance is not intended for use by persons 

  (including children) with reduced physical, sensory or 

  mental capabilities, or lack of experience and knowledge, 

  unless they have been given supervision or instruction 

  concerning use of the appliance by a person responsible 

  for their safety. Children should be supervised to ensure 

  that they do not play with the appliance. 

•  In order to avoid a hazard due to inadvertent resetting 

  of the thermal cut-out, this appliance must not be 

  supplied through an external switching device, such as 

  a timer, or connected to a circuit that is regularly 

  switched on and off by the utility.

Filter Unit

O P

E

N

C L O

S

E

FILTER

CLEANING

O Ring

• Do not block the Shower Head with 

  hand, towel or bend the Shower 

  Hose. The water flow rate will drop 

  and water temperature may become 

  very hot.
• Take care not to damage the  

  holes of the Shower Plate during  

  the cleaning. The Rubber Packing  

  shall be set on the Shower Head  

  before fixing back the Shower  

  Plate to Shower Head. Do not  

  remove part other than Shower 

  Plate and Rubber Packing.

Rubber 

Packing

Shower

Head

Shower 

Plate

•  Each time shower water is turned ‘ON’, check the water 

  temperature by hand before showering.

Summary of Contents for DH-3PL1PH

Page 1: ...e Shower This appliance is intended for household use only For optimum performance and safety please carefully read this Operating Instructions and keep this documentation in a safe place for future reference DH 3PL1 Model No O P E N C L O S E FILTER CLEANING ELB Test ELB Reset Push Up OFF MAX Power Control Main Switch ELB Off Off High On ...

Page 2: ...carefully To prevent personal injury injury to others and property damage the following instructions must be followed Incorrect operation caused by failure to follow instructions will cause harm or damage the seriousness of which is classified as follow SAFETY INSTRUCTIONS To be followed absolutely CONTENTS Page No BEFORE USING ELECTRIC HOME SHOWER 1 SAFETY INSTRUCTIONS 2 PARTS IDENTIFICATION 3 AC...

Page 3: ...ectric home shower Unit to avoid physical and electric shock hazards If the ELB Reset Lever cannot be reset even if you push it up or if it soon slides down during operation please do not use the Unit and contact the authorized dealer immediately to avoid a hazard to users such as damage to property serious injury or death Never fix the ELB Reset Lever forcibly with tape and such Do not replace th...

Page 4: ...Filter Body Packing OPEN C L O S E FILTE R CLEANIN G OFF MA X O P EN C L O S E FIL TE R CLE AN ING O F F M A X O P E N C L O S E FILTER CLEANING OFF MAX ELB Test ELB Reset Push Up Power Control Main Switch ELB Off Off High On O P E N C L O S E FILTER CLEANING OFF MAX ELB Lamp Filter Body Assembly Installation การติดตั งชิ นส วนประกอบตัวเครื องกรอง Place Rubber Packing between Filter Body Assembly ...

Page 5: ...alve Step 1 Turn OFF the Main Water Valve Step 2 Turn the Shower Head upward at waist height Step 3 Turn the Water Volume Knob clockwise to maximum volume position Step 4 Gradually turn ON the Main Water Valve and adjust the splashing height H of the shower It is recommended to adjust the water splashing height H at 100 cm 110 cm approximately 3 L min Note 1 After setting maximum flow rate please ...

Page 6: ...an it with moist cloth 2 Never use benzene thinner detergent bleach and such 3 Do not spray water to the Unit nor put wet towels on it 4 Make sure to use suitable cloth to clean the Front Plate surface to avoid scratch 2 Shower Head cleaning Turn the Shower Plate anticlockwise and remove it from the Shower Head with hand Clean the Shower Head s holes by using a soft brush from time to time Recomme...

Page 7: ... down Push up the ELB Reset Lever to reset the ELB refer to TEST OPERATION at page 11 3 Make sure to switch on the ON OFF DP double pole Switch 4 Make sure to switch on the Miniature Circuit Breaker MCB 1 Check the Water Volume Knob Turn the Water Volume Knob clockwise if it is closed 2 Check the Main Water Valve Turn ON the Main Water Valve if it is closed refer to HOW TO USE at page 5 1 Check th...

Page 8: ...outlet inlet water cannot be filtered and allows foreign particles to enter the Unit It will cause Heater Unit and Shower Head to clog up Do not install remove and reinstall the Unit by yourself Improper installation will cause leakage electric shock or fire Installation and wiring must be done by competent personnel Do not share the inlet and outlet pipe of the Home Shower Unit with other outlets...

Page 9: ... N to the ELB L N and earth wire to the Ground Point with 1 N m 10 kgf cm torque Fix back the Cord Holder to its position to clamp the Flexible Cord Connect wires in correct polarity L N Connecting the wires in wrong polarity L N causes an abnormal condition which may lead to electric leaking burning and such Before wiring please check polarity L N with voltage range of a tester or voltmeter by co...

Page 10: ...all or tiles If the Adjust Holder needs to be cut due to different wall height make sure the Adjust Holder is touching to the wall or tiles to prevent possibility of water leakage at the Filter Body Assembly Touching to the wall tiles wall tiles Touching to the wall tiles tiles tiles Cut Adjust Holder About 5 mm The Unit must be earthed Earth Rod fixing procedure Select suitable place to bury the ...

Page 11: ...ng to the sequence as illustrated Push in the Main Switch Knob and Power Control Knob until it is fully inserted Main Switch Knob and Power Control Knob can not be inserted if Step and Step is not done accordingly Fix the screw at the bottom of the Unit Note 1 Do not push the ELB Test Button during fixing the Front Plate 2 Do not apply extreme force to insert the Main Switch Knob and Power Control...

Page 12: ... Manufacturing Malaysia Berhad 2019 H0919Z1 20621 Panasonic Manufacturing Malaysia Berhad 196501000304 No 3 Jalan Sesiku 15 2 Section 15 Shah Alam Industrial Site 40200 Shah Alam Selangor Darul Ehsan Malaysia http www panasonic com ...

Reviews: