6
(EN)
Settings
Setting for receiver
Screw
PCB cover
Receiver PCB
Main/Sub selector
switch for remote
controllers (4)
OFF: Main
ON: Sub
Set its address
(1) to (3)
All set at OFF
when shipped
from the factory.
ON
1 2 3
4
Check the settings of the
[S003] DIP switch on the
receiver’s PCB.
* Remove the cover from the
receiver when performing
the PCB settings.
Setting Address Switches
When more than 1 receiver is installed in the same room, setting addresses prevents interference.
For how to change addresses of wireless remote controllers, see the operating instructions of
wireless remote controllers.
To change the receiver’s address, remove the cover from the receiver’s PCB and set No.1 to No.3
of the [003] DIP switch on PCB.
Remote
Controller
Address
Display
Address Address Address Address Address Address Address ON/OFF
States
ALL
1
2
3
4
5
6
Position
of the
receiver’s
address
switch
Receipt is
possible
at all
of the
address
positions
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
OFF ON
Setting for Wireless Remote Controller
Room Temperature Sensor Settings
The indoor unit and the wireless remote controller are equipped with
room temperature sensors. The sensing of room temperature works via
one of them.
When the unit is shipped, it is set to the indoor unit. To switch it to the
remote controller, press the sensor button (the
fi
gure on the right) inside
the remote controller’s cover and then check that Main Sensor on the
LCD screen goes off.
<Note> Be sure to install the remote controller so as to face the receiver.
If the unit does not receive any room temperature data from the
remote controller for ten minutes even with its sensing function
activated, the indoor unit sensor will automatically start sensing the
room temperature.
Sensor button
Summary of Contents for CZ-RWSU3