2.2. Indoor Unit
Automatic Operation Button
• Press for < 5 second to operate Automatic
operation mode. Used when the remote control
cannot be used.
• Press for
≥
5 second to operate Cooling
operation mode and compressor force to on
(“beep” sound will heard). Used when test
running or servicing.
• Within 20 second of Cooling operation, press
continuously for
5 second to enter various
setting mode. “beep, beep” sound will be heard.
(Used to toggle remote control signal receiving
sound or select remote control transmission
code).
AUTO
OFF / ON
Operation Indication Lamps (LED)
7 Minutes Time Save Control
• To reduce the built up humidity inside the room.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor unit
discharge area.
Timer Operation
• Delay OFF/ON Timer control.
Powerful Operation
• Reaches the desired room temperature quickly.
Anti-Freezing Control
• To prevent indoor heat exchanger from freezing.
Random Auto Restart Control
• Unit will be restarted, when resume from power
failure, at previous setting.
Indoor Fan Speed Control
• Manual control fan speed (High, Medium and
Low).
• Automatic fan speed.
• Vertical airflow control can be adjusted
automatically or manually by remote control.
• Horizontal airflow can be manually adjusted by
hand.
Airflow Direction Control
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
Hot-Start Control
• To prevent cold air being discharge during
Heating operation starts.
Starting Current Control
• To reduce the starting current.
Anti Cold Draft Control
• To prevent the cold draft during Heating mode
operation in thermo off condition.
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Operation.
30 Minutes Time Save Control
• Heating operation only.
Quiet Operation
• To provide quiet operation.
Ionizer Operation
• Generate and discharge negative ion.
•
POWER
(Green) ............. Lights up in operation,
blinks in Automatic
Operation judging and
Hot Start operation.
•
TIMER
(Orange) ............ Lights up in Timer
Setting.
•
QUIET
(Orange) ............. Lights up in Quiet
Operation.
•
POWERFUL
(Orange) ...... Lights up in Powerful
Operation.
•
ION
(Green) .................. Lights up in Ionizer
Operation.
•
SUPER
ALLERU-BUSTER
(Blue) ... Lights up in operation.
5
CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
Summary of Contents for CS-W7DKE
Page 15: ...5 Refrigeration Cycle Diagram 15 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 16: ...6 Block Diagram 16 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 17: ...17 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 18: ...7 Wiring Diagram 18 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 19: ...19 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 75: ...14 3 2 CS W9DKE CU W9DKE 75 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 76: ...14 3 3 CS W12DKE CU W12DKE 76 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 87: ...87 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 89: ...19 2 Remote Control 89 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...
Page 91: ...TOP VIEW 91 CS W7DKE CU W7DKE CS W9DKE CU W9DKE CS W12DKE CU W12DKE...