139
SAFETY REF. NO.
DESCRIPTION & NAME
QTY.
CU-VE9NKE
CU-VE12NKE
REMARK
1
CHASSIS
1
CWD50K2229
←
2
HEATER
1
CWA341072
←
3
ANTI-VIBRATION
BUSHING
3
CWH50077
←
4 COMPRESSOR
1 CWB092610
←
O
5
MULTIBENT
TUBE
1
CWT338949
←
6
PARTICULAR
PIECE
1
CWD933310
←
7
SENSOR-COMPLETE
1
CWA50C2676
←
8
TERMINAL
COVER
1
CWH171053
←
9
NUT-TERMINAL
COVER
1
CWH7080300J
←
10
HEAT
CHARGER
1
CWH90C0037X
←
11
SENSOR-COMPLETE
1
CWA50C2742XE
←
O
12
NUT
2
CWH56000J
←
13
FAN MOTOR BRACKET
1
CWD541140
←
14 MOTOR
(SMALL
DC)
1
ARS8406AC
←
O
15
SCREW
4
CWH55252J
←
16
PROPELLER
FAN
ASSY
1
CWH03K1067
←
17
NUT
1
CWH56053J
←
18
HEAT
EXCHANGER
1
CWB32C3187
←
19
TUBE ASS'Y (4-WAYS VALVE)
1
CWT028012
←
20
3-WAYS
VALVE
1
CWB011654
←
O
21
HOLDER-COUPLING
1
CWH351180
←
22
2-WAYS
VALVE
1
CWB021540
←
O
23
TUBE ASS'Y (2-WAYS VALVE)
1
CWT028014
←
24
MANIFOLD
TUBE
1
CWT071013
←
25
TUBE ASS'Y (STRAINER)
1
CWT028162
←
26
TUBE ASS'Y (EXPANSION VALVE)
1
CWT027235
←
27
TUBE ASS'Y (STRAINER)
1
CWT027224
←
28
TUBE ASS'Y (2-WAYS VALVE)
1
CWT028175
←
29
MANIFOLD
TUBE
1
CWT071014
←
30
SOUND-PROOF
BOARD
1
CWH15C1066
←
31 REACTOR
1 G0C392J00011
←
32
SOUND PROOF MATERIAL
1
CWG302688
←
33
PARTICULAR
PLATE-A'SSY
1
CWD90K1059
←
34
CONTROL BOARD COVER
1
CWH131550
←
35
TERMINAL BOARD ASS'Y
1
CWA28K1121
←
O
36
SENSOR-COMPLETE
1
CWA50C2765
←
O
37
HOLDER-SENSOR
1
CWH321091
←
38 ELECTRONIC
CONTROL-MAIN
1 CWA73C6695R CWA73C6696R
O
39
V-COIL 4-WAYS VALVE
1
CWA43C2400
←
40
SCREW
1
CWH551298
←
41
V-COIL EXPANTION VALVE
1
CWA43C2413
←
42
V-COIL 2-WAYS VALVE
1
CWA43C2426
←
43
SCREW
1
CWH551068J
←
44
V-COIL 2-WAYS VALVE
1
CWA43C2471
←
45
SCREW
1
CWH551068J
←
46
HOLDER-SENSOR
1
CWH321048
←
47
SENSOR-COMPLETE
1
CWA50C2746
←
O
48
HOLDER-SENSOR
1
CWH321048
←
49
CABINET
SIDE
PLATE
1
CWE04C1401
←
50
CABINET
SIDE
PLATE
1
CWE041673
←
51
SOUND PROOF MATERIAL
1
CWG302588
←
52
CABINET FRONT PLATE
1
CWE06C1436
←
53
CABINET TOP PLATE
1
CWE031130
←
54
WIRE NET.RESIN NET
1
CWD041143
←
55
UNION NUT 1/4"
1
CWT251048
←
Summary of Contents for CS-VE9NKE
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit and Remote Control...
Page 14: ...14 5 2 Outdoor Unit...
Page 15: ...15 6 Refrigeration Cycle Diagram...
Page 16: ...16 7 Block Diagram...
Page 17: ...17 8 Wiring Connection Diagram 8 1 Indoor Unit...
Page 18: ...18 8 2 Outdoor Unit...
Page 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Page 20: ...20 9 2 Outdoor Unit...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board...
Page 22: ...22 10 1 2 Printed Circuit Board...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board...
Page 27: ...27...
Page 68: ...68 15 4 Self diagnosis Method 15 4 1 H11 Indoor Outdoor Communication Error Troubleshooting...
Page 69: ...69 15 4 2 H14 Indoor Unit Intake Air Temperature Sensor Error Troubleshooting...
Page 71: ...71 15 4 8 H53 Heat Storage Tank Temperature Sensor Error Troubleshooting...
Page 72: ...72 15 4 9 H16 Outdoor Unit CT Disconnection Error Troubleshooting...
Page 73: ...73 15 4 10 H19 Indoor Unit Fan Motor Lock Error Troubleshooting...
Page 75: ...75 15 4 12 H38 Brand not Corresponding Troubleshooting...
Page 76: ...76 15 4 13 H50 Ventilation Fan Motor Error Troubleshooting...
Page 77: ...77 15 4 14 H51 Filter Cleaning Nozzle Lock Error Troubleshooting...
Page 78: ...78 15 4 15 H59 Infrared Sensor Error Troubleshooting...
Page 79: ...79 15 4 16 H67 NANOE Error Troubleshooting...
Page 80: ...80 15 4 17 H70 Sunlight Sensor Error Troubleshooting...
Page 81: ...81 15 4 18 H96 2 and 3 Way Valve Opening Failure Check Troubleshooting...
Page 82: ...82 15 4 19 H97 Outdoor Unit Fan Motor Lock Error Troubleshooting...
Page 83: ...83 15 4 20 H98 Indoor Unit Overpressure Protection Troubleshooting...
Page 85: ...85 15 4 22 F11 Cooling Heating Switching Error Troubleshooting...
Page 86: ...86 15 4 23 F16 Cooling Dry Switching Error Troubleshooting...
Page 87: ...87 15 4 24 F19 Heat Storage Cycle Error Troubleshooting...
Page 88: ...88 15 4 25 F90 PFC Protection Troubleshooting...
Page 89: ...89 15 4 26 F91 Refrigeration Cycle Error Troubleshooting...
Page 90: ...90 15 4 27 F93 Compressor Rotation Error Troubleshooting...
Page 91: ...91 15 4 28 F95 Overpressure Protection in Case of Cooling Error Troubleshooting...
Page 92: ...92 15 4 29 F96 Transistor Module Over temperature Protection Troubleshooting...
Page 93: ...93 15 4 30 F97 Compressor Over temperature Protection Troubleshooting...
Page 94: ...94 15 4 31 F98 Total Current Protection Control Troubleshooting...
Page 95: ...95 15 4 32 F99 DC Peak Operation Error Troubleshooting...
Page 127: ...127 Heating Characteristic Condition Room temperature 20 C DBT Piping length 5m Fh 37Hz...
Page 131: ...131 Heating Characteristic Condition Room temperature 20 C DBT Piping length 5m Fh 49Hz...
Page 134: ...134 18 Exploded View and Replacement Parts List 18 1 Indoor Unit...