background image

13

English

Safety precautions

If the supply cord is damaged, it must be 

replaced by the manufacturer, service agent or 

similarly quali

fi

 ed persons in order to avoid a 

hazard.
It is strongly recommended to be installed 

with Earth Leakage Circuit Breaker (ELCB) 

or Residual Current Device (RCD) to prevent 

electric shock or 

fi

 re.

To prevent overheating, 

fi

 re or electric shock:

• Insert the power plug properly.

• Dust on the power plug should be periodically 

wiped with a dry cloth.

Stop using the product if any abnormality/failure 

occurs and disconnect the power plug or turn off 

the power switch and breaker.

(Risk of smoke/

fi

 re/electric shock) Examples of 

abnormality/failure

• The ELCB trips frequently.

• Burning smell is observed.

• Abnormal noise or vibration of the unit is 

observed.

• Water leaks from the indoor unit.

• Power cord or plug becomes abnormally hot.

• Fan speed cannot be controlled.

• The unit stops running immediately even if it is 

switched on for operation.

• The fan does not stop even if the operation is 

stopped.

Contact your local dealer immediately for 

maintenance/repair.
Replacement or installation of power plugs shall

be performed by authorised/quali

fi

 ed personnel

only. The wires in this mains lead are coloured in

accordance with the following code:

Terminals

Red

wires

live

neutral

earth

colours (GB Standard)

blue

green-yellow

brown

Black

Green/Yellow

Wiring colour may vary depending on a country

wiring code’s standard.

This equipment must be earthed to prevent 

electrical shock or 

fi

 re.

Prevent electric shock by switching off the power 

supply and unplug:

- Before cleaning or servicing,

- When extended non-use, or

- During abnormally strong lightning activity.

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzine, 

thinner or scouring powder to avoid damage or 

corrosion at the unit.
Do not use for preservation of precise equipment, 

food, animals, plants, artwork or other objects. 

This may cause quality deterioration, etc.
Do not use any combustible equipment in front of 

the air

fl

 ow outlet to avoid 

fi

 re propagation.

Do not expose plants or pet directly to air

fl

 ow to 

avoid injury, etc.

Do not touch the sharp aluminium 

fi

 n, 

sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 

the 

fl

 oor. After waxing, aerate the room properly 

before operating the unit.
Do not install the unit in oily and smoky areas to 

prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to 

avoid injury.
Do not step onto an unstable bench when 

cleaning the unit to avoid injury.
Do not place a vase or water container on the 

unit. Water may enter the unit and degrade the 

insulation. This may cause an electric shock.
Do not open window or door for long time during 

COOL/DRY mode operation.
Prevent water leakage by ensuring drainage 

pipe is:

- Connected properly,

- Kept clear of gutters and containers, or

- Not immersed in water
After a long period of use or use with any 

combustible equipment, aerate the room 

regularly.
After a long period of use, make sure the 

installation rack does not deteriorate to prevent 

the unit from falling down.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It may 

damage the remote control.

To prevent malfunction or damage of the remote 

control:

• Remove the batteries if the unit is not going to 

be used for a long period of time.

• New batteries of the same type must be 

inserted following the polarity stated.

Power supply

Do not disconnect the plug by pulling the cord to 

prevent electric shock.

Summary of Contents for CS-V7PWA

Page 1: ...CU V18PWA Operating Instructions Air Conditioner F568969 2 11 Panasonic Operating Instructions Air Conditioner 12 21 Thank you for purchasing Panasonic Air Conditioner Installation instructions attach...

Page 2: ...T FAN SPEED OFF TIMER ON TIMER FAN SPEED AIR SWING AUTO COOL DRY TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET 1 2 3 V7PWA V9PWA V12PWA SET CLOCK RESET FAN SPEED AIR SWING AUTO COOL DRY MODE POWERFUL...

Page 3: ...the unit within the recommended temperature may save energy COOL 26 C 28 C DRY 1 C 2 C lower than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use re...

Page 4: ...4...

Page 5: ...5 ELCB RCD ELCB GB ON COOL DRY Ni Cd...

Page 6: ...EED AIR SWING AUTO COOL DRY TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET TEMP OFF ON TIMER SET CANCEL ON OFF 1 2 3 CLOCK 10 C F OFF ON AUTO COOL V7PWA V9PWA V12PWA MODE AUTO AUTO 23 C COOL 25 C 23 C...

Page 7: ...OFF TIMER 3 SET OFF TIMER TIMER ON OFF CANCEL ON OFF ON 15 SET NANOE G NANOE G OFF ON nanoe G AUTO NANOE G POWER nanoe G 30 COOL DRY nanoe G 2 NANOE G nanoe G nanoe G NANOE G AIR SWING COOL DRY AUTO P...

Page 8: ...N TIMER SET CANCEL ON OFF 1 2 3 AIR SWING FAN SPEED NANOE G CLOCK TEMP OFF ON TIMER SET CANCEL ON OFF 1 2 3 V18PWA POWER TIMER NANOE G POWERFUL QUIET MODE AUTO AUTO 23 C COOL 25 C 23 C DRY 22 C HI 2 C...

Page 9: ...43 26 16 11 16 11 NANOE G NANOE G OFF ON nanoe G AUTO NANOE G POWER nanoe G 30 COOL DRY nanoe G 2 NANOE G nanoe G nanoe G NANOE G AIR SWING COOL DRY AUTO ON OFF TIMER SET CANCEL ON OFF 1 2 3 CANCEL 3...

Page 10: ...10 pH 7 40 C POWER TIMER NANOE G POWERFU L QUIET 1 2 CS V18PWA 4 POWER TIMER NANOE G POWERFU L QUIET 1 3 2 nanoe G 6 2 15 COOL 8 C nanoe G 2 3 POWER TIMER NANOE G POWERF UL QUIET nanoe G...

Page 11: ...11 TIMER COOL...

Page 12: ...ric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc...

Page 13: ...ly strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for pres...

Page 14: ...9PWA V12PWA MODE To select operation mode AUTO mode For your convenience Unit selects the operation mode according to the room temperature Once AUTO mode is selected the unit will operate at the stand...

Page 15: ...ctivate only once a day after the unit turned off To remove the moisture left in the internal parts the fan will operate for 30 minutes with louver opened slightly This process only applicable when th...

Page 16: ...ence Unit selects the operation mode according to the room temperature Once AUTO mode is selected the unit will operate at the standard setting temperature Room temperature Operation mode Standard set...

Page 17: ...ntil a long beep sound is heard AIR SWING To adjust airflow direction Remote control display Keeps the room ventilated In COOL DRY mode if AUTO is set the louver swings left right and up down automati...

Page 18: ...front panel 3 Close down 2 nanoe G Generator Every 6 months Clean with dry cotton bud Do not touch during operation Air filters Every 2 weeks Wash rinse the filters gently with water to avoid damage t...

Page 19: ...eck Operation in COOL mode is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents...

Page 20: ...sal in other Countries outside the European Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the...