How to use

NANOE-G

To purify the air

NANOE-G

• nanoe-G starts automatically when the unit is turned 

on with 

OFF/ON

.

• Can be activated even when the unit is turned off. 

In this condition, the unit will operate as a fan with 

AUTO fan speed and louver swing.

To deactivate viruses/bacteria on the fi lter

NANOE-G

POWER

• Depending on the unit’s accumulated operation 

time, nanoe-G in-

fi

 lter deactivation may activate only 

once a day after the unit turned off.

• To remove the moisture left in the internal parts, the 

fan will operate for 30 minutes with louver opened 

slightly. This process only applicable when the unit 

is operated in COOL/DRY mode before turned off. 

Then, nanoe-G deactivates viruses/bacteria on the 

fi

 lter for 2 hours with fan stopped and louver closed.

• Do not turn off the power supply during this 

operation. After power failure, this operation will not 

resume.

• To disable this operation in the future, press and 

hold 

NANOE-G

 until a short beep sound is heard. This 

will not disable the nanoe-G to purify the air.

• To restore the nanoe-G in-

fi

 lter deactivation, press 

and hold 

NANOE-G

 until a long beep sound is heard. 

AIR SWING

To adjust airfl ow direction

(Remote control display)

• Keeps the room ventilated.

• In COOL/DRY mode, if AUTO is set, the louver 

swings left/right and up/down automatically.

• Do not adjust the louver by hand.

Note

POWERFUL/

QUIET

NANOE-G

• Can be activated in all modes and can be 

cancelled by pressing the respective button 

again.

POWERFUL/

QUIET

• Cannot be selected at the same time.

Operation conditions

Use this air conditioner under the following 

temperature range.
DBT  : Dry bulb temperature

WBT  : Wet bulb temperature

Temperature (°C)

Indoor

Outdoor

DBT

WBT

DBT

WBT

COOL

Max.

32

23

43

26

Min.

16

11

16

11

To set the timer

To turn ON or OFF the unit at a preset time.

TIMER

SET

CANCEL

ON

OFF

1

2

3

CANCEL

3

2

1

3

1

Select ON or OFF 
timer

Example: 
OFF at 22:00

OFF

2

Set the time

2

3

Confi rm

SET

TIMER

• To cancel ON or OFF timer, press 

ON

 or 

OFF

 then press 

CANCEL

.

• When ON Timer is set, the unit may start 

earlier (up to 15 minutes) before the actual 
set time in order to achieve the desired 
temperature on time.

• Timer operation is based on the clock set in 

the remote control and repeats daily once 
set. For clock setting, please refer to Quick 
guide.

• If timer is cancelled manually or due to 

power failure, you can restore the previous 
setting (once power is resumed) by pressing 

SET

.

Summary of Contents for CS-V7PWA

Page 1: ...CU V18PWA Operating Instructions Air Conditioner F568969 2 11 Panasonic Operating Instructions Air Conditioner 12 21 Thank you for purchasing Panasonic Air Conditioner Installation instructions attach...

Page 2: ...T FAN SPEED OFF TIMER ON TIMER FAN SPEED AIR SWING AUTO COOL DRY TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET 1 2 3 V7PWA V9PWA V12PWA SET CLOCK RESET FAN SPEED AIR SWING AUTO COOL DRY MODE POWERFUL...

Page 3: ...the unit within the recommended temperature may save energy COOL 26 C 28 C DRY 1 C 2 C lower than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use re...

Page 4: ...4...

Page 5: ...5 ELCB RCD ELCB GB ON COOL DRY Ni Cd...

Page 6: ...EED AIR SWING AUTO COOL DRY TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET TEMP OFF ON TIMER SET CANCEL ON OFF 1 2 3 CLOCK 10 C F OFF ON AUTO COOL V7PWA V9PWA V12PWA MODE AUTO AUTO 23 C COOL 25 C 23 C...

Page 7: ...OFF TIMER 3 SET OFF TIMER TIMER ON OFF CANCEL ON OFF ON 15 SET NANOE G NANOE G OFF ON nanoe G AUTO NANOE G POWER nanoe G 30 COOL DRY nanoe G 2 NANOE G nanoe G nanoe G NANOE G AIR SWING COOL DRY AUTO P...

Page 8: ...N TIMER SET CANCEL ON OFF 1 2 3 AIR SWING FAN SPEED NANOE G CLOCK TEMP OFF ON TIMER SET CANCEL ON OFF 1 2 3 V18PWA POWER TIMER NANOE G POWERFUL QUIET MODE AUTO AUTO 23 C COOL 25 C 23 C DRY 22 C HI 2 C...

Page 9: ...43 26 16 11 16 11 NANOE G NANOE G OFF ON nanoe G AUTO NANOE G POWER nanoe G 30 COOL DRY nanoe G 2 NANOE G nanoe G nanoe G NANOE G AIR SWING COOL DRY AUTO ON OFF TIMER SET CANCEL ON OFF 1 2 3 CANCEL 3...

Page 10: ...10 pH 7 40 C POWER TIMER NANOE G POWERFU L QUIET 1 2 CS V18PWA 4 POWER TIMER NANOE G POWERFU L QUIET 1 3 2 nanoe G 6 2 15 COOL 8 C nanoe G 2 3 POWER TIMER NANOE G POWERF UL QUIET nanoe G...

Page 11: ...11 TIMER COOL...

Page 12: ...ric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc...

Page 13: ...ly strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for pres...

Page 14: ...9PWA V12PWA MODE To select operation mode AUTO mode For your convenience Unit selects the operation mode according to the room temperature Once AUTO mode is selected the unit will operate at the stand...

Page 15: ...ctivate only once a day after the unit turned off To remove the moisture left in the internal parts the fan will operate for 30 minutes with louver opened slightly This process only applicable when th...

Page 16: ...ence Unit selects the operation mode according to the room temperature Once AUTO mode is selected the unit will operate at the standard setting temperature Room temperature Operation mode Standard set...

Page 17: ...ntil a long beep sound is heard AIR SWING To adjust airflow direction Remote control display Keeps the room ventilated In COOL DRY mode if AUTO is set the louver swings left right and up down automati...

Page 18: ...front panel 3 Close down 2 nanoe G Generator Every 6 months Clean with dry cotton bud Do not touch during operation Air filters Every 2 weeks Wash rinse the filters gently with water to avoid damage t...

Page 19: ...eck Operation in COOL mode is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents...

Page 20: ...sal in other Countries outside the European Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the...

Reviews: