61
11.11 nanoe-G
Operation
•
This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate molds, bacteria or viruses.
•
nanoe-G operation start condition
o
During unit running at any operation mode, if nanoe-G operation is activated, combination operation
(operation mode + nanoe-G operation) starts.
o
During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.
•
nanoe-G operation stop condition
o
When OFF/ON button is pressed to stop the operation.
o
When nanoe-G button is pressed.
o
When OFF Timer activates.
•
nanoe-G operation pause condition
o
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after
indoor fan restarts.
o
When indoor intake temperature
≥
40°C. nanoe-G operation resume after indoor intake temperature
≤
40°C
continuously for 30 minutes.
•
Indoor
fan
control
o
During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.
However, nanoe-G system enabled when fan speed
≥
500rpm to ensure proper negative ion distribution,
nanoe-G system disabled when fan speed < 500 rpm.
o
During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan
Speed for nanoe-G operation changes from SHi to Hi after 4 hours of operation.
•
Airflow direction control
o
During any operation mode combines with nanoe-G operation, airflow direction follows respective operation
mode.
o
During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
signal is sent to the unit and no change on remote control display.
•
Timer
control
o
When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G
operation status.
o
When ON Timer activates during any operation, no change on current operation.
o
When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status
is saved.
•
Indicator
o
When nanoe-G starts, nanoe-G indicator ON.
•
Remote control receiving sound
o
Normal
operation
Î
nanoe-G operation
: Beep
o
Nanoe-G
operation
Î
Normal operation
: Beep
o
Stop
Î
nanoe-G individual operation : Beep
o
Nanoe-G individual operation
Î
Stop
:
Long
Beep
•
Power
failure
o
During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual
operation resumes immediately.
o
During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.
o
nanoe-G operation status is not memorized after OFF the unit. After OFF the unit, when the operation is ON
again, air conditioner operates without nanoe-G operation.
Summary of Contents for CS-S9NKV
Page 15: ...15 4 2 3 CU S18NKV CU S24NKV...
Page 16: ...16 4 2 4 CU S28NKV...
Page 17: ...17 5 Refrigeration Cycle Diagram 5 1 CS S9NKV CU S9NKV CS S12NKV CU S12NKV...
Page 18: ...18 5 2 CS S18NKV CU S18NKV CS S24NKV CU S24NKV...
Page 19: ...19 5 3 CS S28NKV CU S28NKV...
Page 24: ...24 7 Wiring Connection Diagram 7 1 Indoor Unit 7 1 1 CS S9NKV CS S12NKV...
Page 25: ...25 7 1 2 CS S18NKV CS S24NKV...
Page 26: ...26 7 1 3 CS S28NKV...
Page 31: ...31 8 Electronic Circuit Diagram 8 1 Indoor Unit 8 1 1 CS S9NKV CS S12NKV...
Page 32: ...32 8 1 2 CS S18NKV CS S24NKV...
Page 33: ...33 8 1 3 CS S28NKV...
Page 41: ...41 9 1 5 Human Activity Sensor Printed Circuit Board...
Page 42: ...42 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU S9NK...
Page 43: ...43 9 2 1 2 CU S12NK...
Page 44: ...44 9 2 1 3 CU S18NK CU S24NK...
Page 45: ...45 9 2 1 4 CU S28NK...
Page 46: ...46 9 2 2 Noise Filter Printed Circuit Board 9 2 2 1 CU S9NKV...
Page 47: ...47 9 2 2 2 CU S28NKV...