Panasonic CS-RZ25WKRW Operating Instructions Manual Download Page 14

14

To learn more...

Operation mode

• It is possible to operate the indoor units individually or simultaneously. The priority of 

operation is placed on the fi rst unit that turned on.

• During operation, HEAT and COOL modes cannot activate at the same time for different 

indoor units.

• The power indicator blinks to indicate the indoor unit is standing by for different operation 

mode.

AUTO :

During operation, the POWER indicator will blinks at initial.

Single

• Unit selects operation mode every 10 minutes according to the setting and room 

temperatures.

Multi

• Unit selects operation mode every 3 hours according to setting temperature, 

outdoor temperature and room temperature.

HEAT :

The POWER indicator blinks at the initial stage of this operation. Unit takes a while 
to warm up.
• For system which HEAT mode has been locked, if operation mode other than 

HEAT is selected, the indoor unit stops and the POWER indicator blinks.

COOL :

Provides effi cient comfort cooling to suit your needs.

DRY

:

Unit operates at low fan speed to give a gentle cooling operation.

FAN

:

To circulate air in the room.

Energy saving temperature setting

Operating the unit within the recommended temperature range may save energy.

HEAT : 

20.0 °C ~ 24.0 °C / 68 °F ~ 75 °F.

COOL: 

26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F. 

Air fl ow direction

In COOL/DRY mode:

If AUTO is set, the fl ap swings up/down automatically. 

In HEAT mode:

If AUTO is set, the horizontal fl ap is fi xed at predetermined position. 

Auto restart control

If power is resumed after a power failure, the operation will restart automatically after a 
period of time with previous operation mode and airfl ow direction.
• This control is not applicable when TIMER is set.

Single

Single split system

Multi

Multi split system

ACXF55-28780_SS0720-0.indd   14

25/6/2020   11:10:09 AM

Summary of Contents for CS-RZ25WKRW

Page 1: ...ckaged in the indoor unit and removed by the installer before installation Kindly consult authorised dealer for connectivity validity Operating Instructions Air Conditioner Model No Indoor Unit Outdoo...

Page 2: ...time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm SET Flexibility to connect Single Split System or Multi Split System Air Conditioner to su...

Page 3: ...nit They are subject to change without notice for future improvement B Basic operation 2 Press MODE to select the desired mode AUTO HEAT COOL FAN DRY 1 Press OFF ON OFF ON to start stop the operation...

Page 4: ...usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not use means to accelerate the defrosting process or to clean...

Page 5: ...d animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propagation Do not expose plants or...

Page 6: ...taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use of flammable refrigerants a...

Page 7: ...12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised and maintained by a...

Page 8: ...re 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenanc...

Page 9: ...ected from the equipment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operati...

Page 10: ...with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that mechanical handling equipment is available if required for handling refrigerant cylinde...

Page 11: ...er of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for the...

Page 12: ...aving without sacrificing comfort To switch between POWERFUL ECO POWERFUL ECO Upper direction Do not adjust the flap by hand Lateral direction For lateral direction it is manually adjustable as shown...

Page 13: ...ll activate in sequence Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick Guide 2 sets of ON and OFF timers are availab...

Page 14: ...em which HEAT mode has been locked if operation mode other than HEAT is selected the indoor unit stops and the POWER indicator blinks COOL Provides efficient comfort cooling to suit your needs DRY Uni...

Page 15: ...BT DBT WBT DBT WBT COOL Max 32 89 6 23 73 4 46 114 8 26 78 8 46 114 8 26 78 8 Min 16 60 8 11 51 8 10 14 0 10 14 0 HEAT Max 30 86 0 24 75 2 18 64 4 24 75 2 18 64 4 Min 16 60 8 15 5 0 15 5 0 16 3 2 DBT...

Page 16: ...r filter Attach air filter Insert into the unit Anti bacterial filter Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dr...

Page 17: ...ue to damp smell emitted by the wall carpet furniture or clothing Cracking sound during operation Changes of temperature caused the expansion contraction of the unit Water flowing sound during operati...

Page 18: ...select COOL HEAT operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet vents COOL 8 C 14 4 F HEAT 14 C 25 2 F The units ar...

Page 19: ...sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdo...

Page 20: ...ows that this equipment uses a flammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Inst...

Reviews: