10
To learn more...
Operation mode
AUTO
:
During operation mode selection the POWER indicator blinks.
• Unit selects operation mode every 10 minutes according to setting temperature
and room temperature.
HEAT
:
Unit takes a while to warm up. The POWER indicator blinks during this
operation.
COOL
:
Provides ef
fi
cient comfort cooling to suit your needs.
DRY
:
Unit operates at low fan speed to give a gentle cooling operation.
FAN
:
To circulate air in the room.
i AUTO-X :
The fast cooling is ideal when you come home on a hot day.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
HEAT :
20.0 °C ~ 24.0 °C / 68 °F ~ 75 °F.
COOL :
26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air
fl
ow direction
In COOL/DRY mode:
If AUTO is set, the
fl
aps swings up/down automatically.
In i AUTO-X mode:
If AUTO is set, the horizontal
fl
ap is
fi
xed at the lower position and shift to the upper
position after reaches set temperature. If manual is set, the horizontal
fl
ap are
fi
xed at the
predetermined position.
In HEAT mode:
If AUTO is set, the horizontal
fl
ap is
fi
xed at the predetermined position.
Auto restart control
If power is resumed after a power failure, the operation will restart automatically after a
period of time with previous operation mode and air
fl
ow direction.
• This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32 (89.6)
23 (73.4)
46 (114.8)
26 (78.8)
Min.
16 (60.8)
11 (51.8)
5 (41.0)
-
HEAT
Max.
30 (86.0)
-
24 (75.2)
18 (64.4)
Min.
16 (60.8)
-
-15 (5.0)
-
DBT: Dry bulb temperature, WBT: Wet bulb temperature
ACXF55-11360_SM0717-0_EN.indd 10
ACXF55-11360_SM0717-0_EN.indd 10
13/6/2017 11:54:32 AM
13/6/2017 11:54:32 AM