17.2 Heat Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Heat mode at 30°C
Voltage: 230V
17.2.1 CS-RE9QKE/CU-RE9QKE
Indoor (°C)
Outdoor WB (°C)
-15 -7 2 7 12
DB
TC IP TC IP TC IP TC IP TC IP
24 2052 946 2525 1084 2887 1020 3313 806 3598 830
20 2162 933 2700 1080 2970 1000 3300 800 3803 812
16 1745 910 2774 1069 3213 1008 3542 821 3710 798
17.2.2 CS-RE12QKE/CU-RE12QKE
Indoor (°C)
Outdoor WB (°C)
-15 -7 2 7 12
DB
TC IP TC IP TC IP TC IP TC IP
24 2379 1099 3290 1434 3647 1314 3702 1110 4074 1183
20 2449 1059 3300 1380 3700 1260 4000 1050 4237 1135
16 2287 1012 3329 1319 3740 1207 3894 993 4350 1075
17.2.3 CS-RE15QKE/CU-RE15QKE
Indoor (°C)
Outdoor WB (°C)
-15 -7 2 7 12
DB
TC IP TC IP TC IP TC IP TC IP
24 2992 1702 3888 1891 4616 1888 4871 1427 5361 1521
20 3080 1640 3900 1820 4930 1810 5000 1350 5575 1459
16 2876 1567 3934 1740 4734 1733 5124 1276 5724 1382
TC - Total Cooling Capacity (W)
SHC - Sensible Heat Capacity (W)
IP - Input Power (W)