5
2. Specifications
Indoor CS-RE9QKE
CS-RE12QKE
Model
Outdoor CU-RE9QKE
CU-RE12QKE
Performance Test Condition
EUROVENT
EUROVENT
Phase, Hz
Single, 50
Single, 50
Power Supply
V 230
230
Min. Mid. Max. Min. Mid. Max.
kW
0.85 2.50 3.00 0.85 3.50 3.90
BTU/h
2900 8530 10200 2900 11900 13300
Capacity
kcal/h
730 2150 2580 730 3010 3350
Running
Current
A
– 2.95 – – 4.40 –
Input
Power
W
250 670 950 255 1.00k
1.19k
Annual
Consumption kWh
– 335 – – 500 –
W/W
3.40 3.73 3.16 3.33 3.50 3.28
BTU/hW 11.60 12.73 10.74 11.37 11.90 11.18
EER
kcal/hW 2.92 3.21 2.72 2.86 3.01 2.82
Pdesign kW
2.5
3.5
SEER (W/W)
6.1
6.1
Annual
Consumption
kWh 143
201
ErP
Class
A++
A++
Power
Factor
%
– 99 – – 99 –
dB-A (H/L/Q-Lo)
41 / 26 / 22
42 / 30 / 22
Indoor Noise
Power Level dB
57
58
dB-A 47
48
Cooling
Outdoor Noise
Power Level dB
62
63
kW
0.80 3.30 4.10 0.80 4.00 5.10
BTU/h
2730 11300 14000 2730 13600 17400
Capacity
kcal/h
690 2840 3530 690 3440 4390
Running
Current
A
– 3.55 – – 4.60 –
Input
Power
W
195 800 1.13k 200 1.05k 1.42k
W/W
4.10 4.13 3.63 4.00 3.81 3.59
BTU/hW 14.00 14.13 12.39 13.65 12.95 12.25
COP
kcal/hW 3.54 3.55 3.12 3.45 3.28 3.09
Pdesign kW
2.4
2.8
Tbivalent °C
-10
-10
SCOP (W/W)
4.0
4.0
Annual
Consumption
kWh 840
980
ErP
Class
A+
A+
Power
Factor
%
– 98 – – 99 –
dB-A (H/L/Q-Lo)
41 / 27 / 25
42 / 33 / 25
Indoor Noise
Power Level dB
57
58
dB-A 48
50
Heating
Outdoor Noise
Power Level dB
63
65
Low Temp. : Capacity (kW) / I.Power (W) / COP
2.97 / 1.00k / 2.97
3.70 / 1.26k / 2.94
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
2.70 / 1.08k / 2.50
3.30 / 1.38k / 2.39
Max Current (A) / Max Input Power (W)
5.0 / 1.13k
6.2 / 1.42k
Starting Current (A)
3.55
4.6