![Panasonic CS-RE9QKE Service Manual Download Page 79](http://html1.mh-extra.com/html/panasonic/cs-re9qke/cs-re9qke_service-manual_4707804079.webp)
79
15.5.26 F98 (Input Over Current Detection)
Malfunction Decision Conditions
During operation of cooling and heating, when an input over-current (X value in Total Running Current Control) is
detected by checking the input current value being detected by current transformer (CT) with the compressor running.
Malfunction Caused
Over-current due to compressor failure.
Over-current due to defective outdoor unit PCB.
Over-current due to defective inverter main circuit electrolytic capacitor.
Over-current due to excessive refrigerant.
Troubleshooting