24
%
$
Wall
Wall
More than 450 mm
More than 450 mm
Screw
219 mm
125 mm
Installation plate
Measuring
tape
224 mm
150 mm
2
1
Wall
Indoor
Outdoor
15 mm
Sleeve for
tube ass’y
Approx. 5 - 7 mm
Bushing for tube ass’y
Putty or caulking compound
Ø 70 through hole
10.2 Indoor Unit
10.2.1 How to Fix Installation Plate
The mounting wall is strong and solid enough to prevent if from the vibration.
The centre of installation plate should be at more
than 450 mm at right and left of the wall.
The distance from installation plate edge to
ceiling should more than 75mm.
From installation plate left edge to unit’s left side
is 148 mm.
From installation plate right edge to unit’s right
side is 152 mm.
ƻ
B
: For left side piping, piping connection for gas should be about 45 mm from this line.
: For left side piping, piping connection cable should be about 800 mm from this line.
1 Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the wall, consider
using anchor bolts.) Always mount the installation plate horizontally by aligning the marking-off line with
the thread and using a level gauge.
2 Drill the piping plate hole with ø70 mm hole-core drill.
z
Put measuring tape at position as shown in the diagram above. The hole centre is
obtained by measuring the distance namely 115 mm and 120 mm for left and right hole
respectively.
z
Drill the piping plate hole at either the right or left and the hole should be slightly slanted
to the outdoor side.
10.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the busing to the sleeve.
3
Cut the sleeve until it extrudes about 15mm from the wall
4
Finish by sealing the sleeve with putty or caulking compound at the
final stage.
Caution
When the wall is hollow, please be sure to use the sleeve for tube
ass’y to prevent dangers caused by mice biting the connecting
cable.
Summary of Contents for CS-RE9JKE
Page 14: ...14 5 2 Outdoor Unit Unit mm...
Page 15: ...15 6 Refrigeration Cycle Diagram CS CU RE9JKE CS CU RE12JKE CS CU RE15JKE COOLING HEATING...
Page 16: ...16 7 Block Diagram CS CU RE15JKE CS CU RE9 12JKE...
Page 17: ...17 8 Wiring Diagram 6 8 5 6 8 5...
Page 18: ...18 6 8 5...
Page 19: ...19 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board TOP VIEW...
Page 20: ...20 BOTTOM VIEW...
Page 21: ...21 9 1 2 Indicator receiver TOP VIEW BOTTOM VIEW...
Page 22: ...22 9 2 Outdoor Unit 9 2 1 CU RE9JKE CU RE12JKE TOP VIEW BOTTOM VIEW...
Page 25: ...25 10 2 3 Indoor Unit Installation...
Page 42: ...42 14 2 3 Error Codes Table...
Page 46: ...46 16 Exploded View and Replacement Pars List 16 1 Indoor Unit CS RE9JKE CS RE12JKE CS RE15JKE...
Page 48: ...48 16 2 Outdoor Unit CU RE9JKE CU RE12JKE...
Page 50: ...50 CU RE15JKE...