![Panasonic CS-RE12NKX Service Manual Download Page 6](http://html.mh-extra.com/html/panasonic/cs-re12nkx/cs-re12nkx_service-manual_1507991006.webp)
6
Lo
m
3
/min (ft
3
/m)
7.57 (267)
9.01 (318)
Me
m
3
/min (ft
3
/m)
8.86 (313)
10.33 (364)
(HEATING)
Hi
m
3
/min (ft
3
/m)
11.1 (392)
12.5 (441)
Hi (Cooling)
m
3
/min (ft
3
/m)
31.4 (1108)
33.0 (1165)
Outdoor Airflow
Hi (Heating)
m
3
/min (ft
3
/m)
31.4 (1108)
33.0 (1165)
Control Device
Capillary Tube
Capillary Tube
Refrigerant Oil
cm
3
FV50S (250)
FV50S (320)
Refrigeration
Cycle
Refrigerant Type g (oz)
R410A, 640 (22.6)
R410A, 780(27.5)
Height(I/D / O/D) mm (inch)
290 (11-15/32) 530 (20-55/64) 290 (11-15/32)
540 (21-1/4)
Width (I/D / O/D) mm (inch)
848 (33-13/32) 720(28-11/32) 848 (33-13/32) 780 (30-45/64)
Dimension
Depth (I/D / O/D) mm (inch)
213(8-3/8)
275 (10-53/64)
213(8-3/8)
289 (11-3/8)
Weight
Net (I/D / O/D)
kg (lb)
8.0 (18)
20 (44)
8.0 (18)
26(57)
Pipe Diameter (Liquid /
Gas)
mm (inch)
6.35 (1/4) / 9.52 (3/8)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5 (16.4)
5 (16.4)
Length range (min – max) m (ft)
3 (9.8) ~ 15 (49.2)
3 (9.8) ~ 15 (49.2)
I/D & O/D Height different m (ft)
5.0 (16.4)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
20 (0.2)
20 (0.2)
P
ip
in
g
Length for Additional Gas m (ft)
7 (23.0)
7 (23.0)
Inner diameter
mm
16
16
Drain Hose
Length
mm
500
500
Fin Material
Pre coated
Pre coated
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 15 x 19
2 x 15 x 19
Indoor
Heat
Exchanger
Size (W x H x L)
mm
610 x 315 x 25.4
610 x 315 x 25.4
Fin Material
Pre coated
Pre coated
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
1 x 24 x 19
2 x 24 x 17
Outdoor
Heat
Exchanger
Size (W x H x D)
mm
661 x 504 x 18.19
703x 504 x 18.19
Material
P.P.HONEY COMB
P.P.HONEY COMB
Air Filter
Type
One-touch
One-touch
Power Supply
Indoor
Indoor
Power Supply Cord
A
10A
10A
Thermostat
-
-
Protection Device
-
-
COOLING
HEATING
COOLING
HEATING
TEMPERATURE (°C )
DB
WB
DB
WB
DB
WB
DB
WB
Maximum
32
23
30
-
32
23
30
-
Indoor Operation Range
Minimum
16
11
16
-
16
11
16
-
Maximum
43
26
24
18
43
26
24
18
Outdoor Operation Range
Minimum
16
11
-5
-6
16
11
-5
-6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bu lb (66.2°F
Wet Bulb) and outdoor air temperature of 35°C Dry B ulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bu lb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor ai r temperature
of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42 .8°F Wet Bulb).
3. Specifications are subjected to change without prior notice for further improvement.
Summary of Contents for CS-RE12NKX
Page 11: ...11 5 Dimensions 5 1 Indoor Unit Unit mm ...
Page 12: ...12 5 2 Outdoor Unit CU RE9NKX Unit mm CU RE12NKX CU RE15NKX ...
Page 13: ...13 6 Refrigeration Cycle Diagram CS CU RE9NKX CS CU RE12NKX CU CU RE15NKX COOLING HEATING ...
Page 14: ...14 7 Block Diagram CS CU RE9NKX CS CU RE12NKX ...
Page 15: ...15 CS CU RE15NKX ...
Page 16: ...16 8 Wiring Diagram CS CU RE9NKX ...
Page 17: ...17 CS CU RE12NKX ...
Page 18: ...18 CS CU RE15NKX ...
Page 20: ...20 9 1 2 Indicator receiver TOP VIEW BOTTOM VIEW ...
Page 21: ...21 9 2 Outdoor Unit 9 2 1 CU RE9NKX TOP VIEW BOTTOM VIEW ...
Page 22: ...22 CU RE12NKX TOP VIEW BUTTOM VIEW ...
Page 23: ...23 CU RE15NKX TOP VIEW BUTTOM VIEW ...
Page 26: ...26 10 2 3 Indoor Unit Installation ...
Page 50: ...50 16 2 Outdoor Unit CU RE9NKX ...
Page 52: ...52 CU RE12NKX CU RE15NKX ...