![Panasonic CS-RE12NKX Service Manual Download Page 33](http://html.mh-extra.com/html/panasonic/cs-re12nkx/cs-re12nkx_service-manual_1507991033.webp)
33
12. Operation Control
12.1 Basic Function
12.1.1 Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting
processes. These shifting processes are depending on the air conditioner settings and the operation environment.
The final shifted value will be used as internal setting temperature and it is updated continuously whenever the
electrical power is supplied to the unit.
12.1.2 Cooling Operation
12.1.2.1
Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5
℃
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature >
Compressor OFF point.
12.1.3 Soft Dry Operation
12.1.3.1
Thermostat control (The same as Cooling mode)
12.1.4 Heating operation
12.1.4.1
Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature > +2.0
℃
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature<
Compressor OFF point.
12.1.5 Automatic Operation
• Once AUTO mode is selected, operation mode is determined by set temperature of remote control and indoor
intake temperature.
1st judgment
JUDGE CONDITION
REFERANCE MODE
If indoor intake temp – Remote control
temp setting
≥
+2
Cool mode
If -2
≤
indoor intake temp. – Remote
control Temp. setting
≤
+2
Dry mode
If indoor intake temp. – Remote control
temp. setting < -2
Heat mode
Remote Control Setting Temp. (16
℃
~30
℃
)
Auto operation Mode Shifting
Outdoor Air Temperature Shifting
Setting Temperature Limit Checking
( Min:16
℃
; Max.:30
℃
)
Setting Temperature Limit Checking( Min:16
℃
; Max.:33
℃
)
Internal Setting Temperature
Summary of Contents for CS-RE12NKX
Page 11: ...11 5 Dimensions 5 1 Indoor Unit Unit mm ...
Page 12: ...12 5 2 Outdoor Unit CU RE9NKX Unit mm CU RE12NKX CU RE15NKX ...
Page 13: ...13 6 Refrigeration Cycle Diagram CS CU RE9NKX CS CU RE12NKX CU CU RE15NKX COOLING HEATING ...
Page 14: ...14 7 Block Diagram CS CU RE9NKX CS CU RE12NKX ...
Page 15: ...15 CS CU RE15NKX ...
Page 16: ...16 8 Wiring Diagram CS CU RE9NKX ...
Page 17: ...17 CS CU RE12NKX ...
Page 18: ...18 CS CU RE15NKX ...
Page 20: ...20 9 1 2 Indicator receiver TOP VIEW BOTTOM VIEW ...
Page 21: ...21 9 2 Outdoor Unit 9 2 1 CU RE9NKX TOP VIEW BOTTOM VIEW ...
Page 22: ...22 CU RE12NKX TOP VIEW BUTTOM VIEW ...
Page 23: ...23 CU RE15NKX TOP VIEW BUTTOM VIEW ...
Page 26: ...26 10 2 3 Indoor Unit Installation ...
Page 50: ...50 16 2 Outdoor Unit CU RE9NKX ...
Page 52: ...52 CU RE12NKX CU RE15NKX ...