8.5. Automatic Mode Operation
1. When the Automatic Mode Operation is selected, the indoor fan operates at SLo fan speed for 25 seconds to sense intake air
temperature and determine the 1st operation mode. If indoor intake air temperature is less than 16°C, Heating mode will
immediate operate.
2. Operation mode will be determine again after 1 hour of operation, if the room temperature reaches to set temperature and
compressor off time is over 7 minutes 30 seconds continuously.
The present operation mode will be continued, if the room temperature does not reach to set temperature (Compressor keeps running)
eventhough after 1 hour from automatic operation mode started.
Present
Judgement
Next Mode
Mode
Cooling
Soft Dry
Heating
O
O
Cooling
23°C
Cooling
(Judgement:
Not Applicable
(Judgement:
Heating
23°C & Above)
Below 23°C)
O
O
Soft Dry
20°C
Soft Dry
Not Applicable
(Judgement:
(Judgement:
Heating
20°C & Above)
Below 20°C)
O
O
Heating
Cooling
(Judgement:
Not Applicable
(Judgement:
25°C
Heating
Above 25°C)
25°C & below)
Automatic Set Temperature
Refer 3. as below.
3. Automatic Set Temperature
For each operation, set temperature will automatically set as shown below.
However it can be selected 2°C higher or 2°C lower from standard set temperature by pressing the “Room Temperature Setting
button”.
Operation
Hi
(Standard)
Lo
(+2°C)
(±0°C)
(-2°C)
Cooling
27°C
25°C
23°C
Soft Dry
24°C
22°C
20°C
Heating
23°C
21°C
19°C
•
•
•
•
The mode judging temperature and standard setting temperature can be increased by 2°C, by open the circuit of JX1 at
indoor electronic controller.
22
CS-PW18CKE CU-PW18CKE
Summary of Contents for CS-PW18CKE
Page 8: ...4 Dimensions 8 CS PW18CKE CU PW18CKE ...
Page 9: ...9 CS PW18CKE CU PW18CKE ...
Page 10: ...5 Refrigeration Cycle Diagram 10 CS PW18CKE CU PW18CKE ...
Page 11: ...6 Block Diagram 11 CS PW18CKE CU PW18CKE ...
Page 12: ...7 Wiring Diagram CS PW18CKE CU PW18CKE 12 ...
Page 15: ...Cooling Operation Time Diagram 15 CS PW18CKE CU PW18CKE ...
Page 17: ...Soft Dry Operation Time Diagram 17 CS PW18CKE CU PW18CKE ...
Page 21: ...a Normal Deicing Time Diagram b Overload Deicing Time Diagram 21 CS PW18CKE CU PW18CKE ...
Page 58: ...14 Technical Data 58 CS PW18CKE CU PW18CKE ...
Page 60: ...60 CS PW18CKE CU PW18CKE ...
Page 68: ...SCHEMATIC DIAGRAM 4 4 68 CS PW18CKE CU PW18CKE ...
Page 70: ...19 1 REMOTE CONTROL 70 CS PW18CKE CU PW18CKE ...
Page 71: ...19 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD TOP VIEW 71 CS PW18CKE CU PW18CKE ...
Page 72: ...19 3 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD BOTTOM VIEW 72 CS PW18CKE CU PW18CKE ...