OPERATION CONDITION

OPERATION CONDITION

Use this air conditioner under the following temperature range
(CU-PC30JKF)

Temperature (°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

COOLING

Maximum

32

23

55

31

Minimum

16

11

16

11

Temperature (°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

COOLING

Maximum

32

23

52

31

Minimum

16

11

16

11

 

 

 

 

 

 

 

 

TABLE OF CONTENTS

TABLE OF CONTENTS

NOTE :

NOTE :

The illustrations in this manual are 
for explanation purposes only and 
may differ from the actual unit. It is 
subjected to change without notice 
for future improvement.

SAFETY PRECAUTIONS

8

REGULATORY INFORMATION

9

PRODUCT OVERVIEW & 

OPERATIONS

10~11

CARE & CLEANING

12

TROUBLESHOOTING

13

QUICK GUIDE

BACK COVER

• Do not switch ON the unit when waxing the 

fl

 oor. After waxing, aerate the room properly before operating the unit.

• Do not install the unit in oily and smoky areas.

Information for Users on Collection and Disposal of Old Equipment and used Batteries

[Information on Disposal in other Countries outside the European Union]

These symbols are only valid in the European Union. If you wish to discard these items, please contact your 

local authorities or dealer and ask for the correct method of disposal.

Note for the battery symbol (bottom two symbol examples): 

This symbol might be used in combination with a chemical symbol. In this case it complies with the 

requirement set by the Directive for the chemical involved. 

Pb

(CU-PC36JKF)

* DBT

:  Dry bulb temperature

* WBT

:  Wet bulb temperature

2_F566726-OYSC0901-00_EN.indd   9

2_F566726-OYSC0901-00_EN.indd   9

1/14/2009   3:29:10 PM

1/14/2009   3:29:10 PM

Summary of Contents for CS-PC30JKF

Page 1: ...erating the unit read these Before operating the unit read these operating instructions thoroughly and operating instructions thoroughly and keep them for future reference keep them for future reference ﺳﺮﻳﻊ ﺩﻟﻴﻞ ﺳﺮﻳﻊ ﺩﻟﻴﻞ QUICK GUIDE QUICK GUIDE Operating Instructions Air Conditioner Indoor Unit Outdoor Unit CS PC30JKF CU PC30JKF CS PC36JKF CU PC36JKF ...

Page 2: ...w batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control Outdoor Unit Do not sit or step on the unit you may fall down accidentally Do not touch the sharp aluminum fin sharp parts may cause injury After long periods of use make sure the installation rack is not damaged Indoor Unit Do not install remove and reinstall the unit by yourse...

Page 3: ...manual are for explanation purposes only and may differ from the actual unit It is subjected to change without notice for future improvement SAFETY PRECAUTIONS 8 REGULATORY INFORMATION 9 PRODUCT OVERVIEW OPERATIONS 10 11 CARE CLEANING 12 TROUBLESHOOTING 13 QUICK GUIDE BACK COVER Do not switch ON the unit when waxing the floor After waxing aerate the room properly before operating the unit Do not i...

Page 4: ...FF SET CANCEL Remote control display Receiver Vertical airflow direction louver Do not adjust by hand Horizontal airflow direction louver Manually adjustable Air Filters Front panel Auto OFF ON button Used when remote control is misplaced or malfunction Action Mode Press once Auto Press and hold until 1 beep is heard then release Cooling Press the button to turn off INDICATOR Green Orange POWER TI...

Page 5: ...TURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving COOL mode 26 C 28 C DRY mode 1 C 2 C lower than room temperature TO SELECT OPERATION MODE AUTO mode For your convenience Unit selects the operation mode according to the room temperature COOL mode To enjoy cool air DRY mode To dehumidify the environment Unit operates at low fan speed to ...

Page 6: ...following conditions Abnormal noise during operation Water foreign particles have entered the remote control Water leaks from Indoor unit Circuit breaker switches off frequently Power cord becomes unnaturally warm Switches or buttons are not functioning properly FOR EXTENDED NON USE FOR EXTENDED NON USE Turn off the power supply Remove the remote control batteries CAUTION Switch off the power supp...

Page 7: ...mptoms do not indicate malfunction The following symptoms do not indicate malfunction Symptom Symptom Check Check Cooling operation is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the front pane...

Page 8: ...ﺣﺪﺓ ﲢﻀﻴﺮ Remote Control Preparation Remote Control Preparation CLOCK RESET TIMER ON 1 2 3 OFF SET CANCEL 4 5 6 F566726 Printed in Malaysia OYSC0901 01 AUTO FAN SPEED AIR SWING COOL OFF OFF TIMER ON TIMER DRY OFF ON TEMP AIR SWING FAN SPEED MODE CLOCK RESET TIMER ON 1 2 3 OFF SET CANCEL 1 AUTO DRY COOL ﺍﳌﺮﻏﻮﺏ ﺍﻟﻮﺿﻊ ﺍﺧﺘﻴﺎﺭ Select the desired mode 2 ﺍﻟﺘﺸﻐﻴﻞ ﺍﻳﻘﺎﻑ ﺑﺪﺀ Start stop the operation 3 ﺍﳌﺮﻏﻮﺑ...