8.3. COMPRESSOR OPERATING FREQUENCY OPERATION
Compressor Operation Frequency According to Comp. Operation Frequency Command Number(INDOOR UNIT)
8.3.1. Cooling & Soft Dry
(Unit : Hz)
Comp.Operation Frequency Command Number of Indoor Unit A
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Comp.
Operation
Frequency
Command
Number of
Indoor Unit B
0
0
15
15
15
15
15
22
30
39
45
47
65
67
67
67
67
1
30
30
39
43
45
47
50
52
56
57
61
61
61
61
61
2
30
30
39
43
45
47
50
52
56
57
61
61
61
61
61
3
39
39
41
45
47
48
52
54
57
59
63
63
63
63
63
4
15
15
15
15
43
43
45
48
50
52
56
57
61
63
67
67
67
67
67
5
15
45
45
47
50
52
54
57
59
63
65
68
68
68
68
68
6
22
47
47
48
52
54
56
59
61
65
67
70
70
70
70
70
7
30
50
50
52
56
57
59
63
65
68
70
74
74
74
74
74
8
39
52
52
54
57
59
61
65
67
70
72
75
75
75
75
75
9
45
56
56
57
61
63
65
68
70
74
75
75
75
75
75
75
10
47
57
57
59
63
65
67
70
72
75
75
76
76
76
76
76
11
65
61
61
63
67
68
70
74
75
75
76
77
77
77
77
77
12
67
61
61
63
67
68
70
74
75
75
76
77
77
77
77
77
13
67
61
61
63
67
68
70
74
75
75
76
77
77
77
77
77
14
67
61
61
63
67
68
70
74
75
75
76
77
77
77
77
77
15
67
61
61
63
67
68
70
74
75
75
76
77
77
77
77
77
Rated and Maximum Operation frequency
Compressor Operation Frequency (Hz)
One Indoor Unit Operation
Two Indoor Units Operation
Fc (10)
47
75
Fc max (15)
67
77
8.3.2. Heating
(Unit : Hz)
Comp.Operation Frequency Command Number of Indoor Unit A
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Comp.
Operation
Frequency
Command
Number of
Indoor Unit B
0
0
15
25
35
45
55
55
65
69
74
75
93
106
118
118
118
1
15
45
55
65
69
71
72
74
75
77
77
78
81
83
83
83
2
25
55
65
69
71
72
74
75
77
78
78
80
83
84
84
84
3
35
65
69
71
72
74
75
77
78
80
80
81
84
86
86
86
4
45
69
71
72
74
75
77
78
80
81
81
83
86
87
87
87
5
55
71
72
74
75
77
78
80
81
83
83
84
87
89
89
89
6
55
72
74
75
77
78
80
81
83
84
84
86
89
90
90
90
7
65
74
75
77
78
80
81
83
84
86
86
87
90
92
92
92
8
69
75
77
78
80
81
83
84
86
87
87
89
92
93
93
93
9
74
77
78
80
81
83
84
86
87
89
89
90
93
94
94
94
10
75
77
78
80
81
83
84
86
87
89
90
92
93
100
100
100
11
93
78
80
81
83
84
86
87
89
90
92
93
94
106
106
106
12
106
81
83
84
86
87
89
90
92
93
93
94
106
112
112
112
13
118
83
84
86
87
89
90
92
93
94
100
106
112
125
125
125
14
118
83
84
86
87
89
90
92
93
94
100
106
112
125
125
125
15
118
83
84
86
87
89
90
92
93
94
100
106
112
125
125
125
Rated and Maximum Operation frequency
Compressor Operation Frequency (Hz)
One Indoor Unit Operation
Two Indoor Units Operation
Fh (10)
75
90
Fh max (15)
118
125
17
CS-MVG103KE / CU-MVG153KE
Summary of Contents for CS-MVG103KE
Page 3: ...2 Functions 2 1 REMOTE CONTROL 3 CS MVG103KE CU MVG153KE ...
Page 4: ...2 2 INDOOR UNIT 4 CS MVG103KE CU MVG153KE ...
Page 5: ...5 CS MVG103KE CU MVG153KE ...
Page 6: ...2 3 OUTDOOR UNIT 6 CS MVG103KE CU MVG153KE ...
Page 9: ...4 Dimensions 4 1 CS MVG103KE INDOOR UNIT 9 CS MVG103KE CU MVG153KE ...
Page 10: ...4 2 CU MVG153KE OUTDOOR UNIT 10 CS MVG103KE CU MVG153KE ...
Page 15: ...8 Operation Details FUNCTIONS 8 1 SIMULTANEOUS OPERATION CONTROL 15 CS MVG103KE CU MVG153KE ...
Page 53: ...11 2 3 PIPING LENGTH 53 CS MVG103KE CU MVG153KE ...
Page 54: ...11 3 INDOOR OUTDOOR UNIT INSTALLATION DIAGRAM 54 CS MVG103KE CU MVG153KE ...
Page 69: ...13 Technical Data 13 1 OPERATION CHARACTERISTICS 69 CS MVG103KE CU MVG153KE ...
Page 70: ...70 CS MVG103KE CU MVG153KE ...
Page 78: ...CS MVG103KE Main PCB Back Side Receiver PCB 78 CS MVG103KE CU MVG153KE ...
Page 79: ...15 2 OUTDOOR UNIT MAIN PCB CU MVG153KE Main PCB Front Side CS MVG103KE CU MVG153KE 79 ...
Page 80: ...CU MVG153KE Main PCB Back Side CS MVG103KE CU MVG153KE 80 ...
Page 84: ...16 2 CU MVG153KE 16 2 1 Exploded View 84 CS MVG103KE CU MVG153KE ...