![Panasonic CS-ME7CB1P Service Manual Download Page 39](http://html1.mh-extra.com/html/panasonic/cs-me7cb1p/cs-me7cb1p_service-manual_4708692039.webp)
Terminals on the indoor unit
1 2 3
Color of wires
Terminals on the outdoor unit
1 2 3
• Secure the cable onto the control board with the holder (clamper).
• Lay the drain piping so as to ensure drainage.
• Use a locally purchased VP20 general rigid PVC pipe (outer
diameter ø26) for the drain piping,
and firmly connect the
indoor unit and the drain piping using PVC adhesive to
ensure that there is no leakage.
• Drain piping located indoors should always be insulated by
wrapping with locally purchased insulation (foamed polyethylene
with a thickness of 10 mm or more).
• The drain piping should have a downward gradient (1/50 or more),
and should be secured using pipe hanging equipment to avoid
creating hills or traps partway.
• Remove the control box cover and lead the connecting cable into the control box.
• Check the colors of the wires on the terminal board, and secure them with screws.
• Secure the outer sheath of the connecting cable with the cord clamp.
• Reattach the control box cover in its original position.
CAUTION
When connecting the
connecting cable, provide
approximately 40 cm of extra
length near the unit to facilitate
servicing of electrical parts.
• Align the center of the half-union and the connection pipe and
tighten the flare nut by hand, then tighten with a torque wrench.
• After the piping is connected, insulate as shown in the illustration
below.
Liquid side ø6.35 (1/4")
Gas side ø9.52 (3/8")
Pipe diameter
Tightening torque
Check the Drainage
Check after connecting the power supply.
• Pour approximately 600 cc of water into the drain pan of the main
unit using a squeeze bottle, etc.
• Press the drain test run switch located on the control board of the
control box to start the drain motor, and check that the water
drains normally. (The drain motor operates for approximately 5
minutes and then stops automatically.) (See the diagram for
“Connecting the Indoor/Outdoor Connecting Cable”.)
18N • m (1.8 kgf • m)
42N • m (4.2 kgf • m)
Connecting the Drain Piping
5
6
Connecting the Indoor/Outdoor
Connecting Cable
7
Connecting and Insulating
the Refrigerant Piping
• Connecting cable between indoor unit and outdoor unit shall be approved
polychloroprene sheathed 4
×
1.5 mm
2
flexible cord, type designation 245 IEC
57(H05RN-F) or heavier cord.
• Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the
indoor’s respectively.
• Earth lead wire shall be longer than the other lead wires as shown in the figure for
the electrical safety in case of the slipping out of the cord from the anchorage.
Absolutely do not install and extend the drain piping from the
main unit drain water outlet horizontally or upward or raise it
20cm or more. Doing so may result in poor drainage or
cause of drain motor failure.
• Should some obstacle prevent the drain piping from being
extended smoothly, the drain piping can be raised outside the
main unit as shown in the illustration below.
CAUTION
20 cm
or less
7 cm
or less
VP20 elbow VP20 pipe
Upward
gradient
or level
Connect the VP20 elbow directly
to the main unit outlet.
Downward gradient
1/50 or more
Trap
No insulation
Insulation (thickness
10 mm or more)
Downward gradient
1/50 or more
Rise
Hill
Half-union
Flare nut
Wrench
Torque wrench for flare nuts
(Auxiliary pipe)
(17 mm and 12 mm end
wrench or adjustable spanner)
(Connection pipe)
Female side
Male side
Piping insulation 1
Band 2
Unit side
Wrap firmly with vinyl tape,
leaving no gaps.
Wrap firmly with vinyl tape,
leaving no gaps.
Piping insulation 1
Band 2
Unit side
Drain pan
Squeeze bottle
Heat
exchanger
Approximately
600 cc of water
“DRAIN TEST” switch
Indoor/outdoor
connection terminals
Earth wire
Cord clamp
Indoor/outdoor
connecting cable
High state switch (SW2)
CS
-M
E
7C
B
1P
/
C
S
-M
E
10CB1
P
/
CS
-M
E
12CB1
P
/
CS
-M
E
14CB1
P
/
CS
-M
E
10CD3
P
/
CS
-M
E
14
CD3P
39
Summary of Contents for CS-ME7CB1P
Page 5: ...3 2 INDOOR UNIT 5 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 6: ...6 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 9: ...9 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 10: ...5 2 Grille 10 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 11: ...5 3 Duct Type 11 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 19: ...19 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 60: ...60 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 61: ...61 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 62: ...62 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...