9 Operation Details (Functions & Protection)
9.1. Simultaneous Operation Control
1.
Operation modes which can be selected using the remote
control unit:
Automatic, Cooling, Dry, Heating, Fan operation mode.
2.
Types of operations modes which can be performed
simultaneously
·
Cooling operation and cooling, Dry or fan operation
·
Heating operation and heating operation
3.
Types of operation modes which cannot be performed
simultaneously
·
While a cooling operation is in progress, a heating operation
cannot be performed by an indoor unit in another room.
In the room where the operation button for cooling was pressed
first, the operation is continued. In the room where the operation
button for heating was pressed afterward, the operation lamp of
the indoor unit blinks, where the attempt is made to establish the
heating operation. Its fan is stopped, and the air does not
discharged.
·
While a heating operation is in progress, a cooling operation
cannot be performed by an indoor unit in another room.
In the room where the operation button for heating was pressed
first, operation is continued. In the room where the operation
button for cooling was pressed afterward, the operation lamp of
the indoor unit blinks, where the attempt is made to establish the
cooling operation. Its fan is stopped, and the air does not
discharged.
4.
Operation mode priority control
·
The operation mode designated first by the indoor unit has
priority.
·
If the priority indoor unit stops operation or initiates the fan
operation, the priority is transferred to other indoor units.
“Waiting”
denotes the standby status in which the operation
lamp LED blinks (ON for 2.5 sec. and OFF for 0.5 sec.), and
the fan is stopped.
* In the fan mode, priority is transferred to a non-priority unit.
Note
C: Cooling operation mode
D: Dry operation mode
H: Heating operation mode
F: Fan operation mode
16
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P
Summary of Contents for CS-ME7CB1P
Page 5: ...3 2 INDOOR UNIT 5 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 6: ...6 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 9: ...9 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 10: ...5 2 Grille 10 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 11: ...5 3 Duct Type 11 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 19: ...19 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 60: ...60 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 61: ...61 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 62: ...62 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...