CHANGING THE REMOTE CONTROL TRANSMISSION CODE
·
When installing two air conditioners in one room, each air conditioner can be synchronized to the remote control.
In order to operate separately, open the rear cover of one of the remote control and set to “B”.
Set “B” on the remote control.
This can be achieved by cutting the jumper wire of the remote control with a cutter.
Setting the air conditioner unit to “B”
1. Press the “AUTO” button for about 11 to 15 seconds. When you hear three short beeps, release the button.
Note: you will hear one beep in about 5 seconds, and then two beeps in about 8 seconds.
2. Press again the “AUTO” button within 60 seconds. Every press the “AUTO” button, you pressing the “AUTO” button,
which achieves “B” setting.
If you stop pressing the “AUTO” button midway at the short beep, this will achieve “A” setting.
3. After 60 seconds or longer of the above setting, use the “B” set remote control to confirm successful operation.
4. Set, A, B, C or D transmission code at remote control. (Fig.1)
5.
Odour clear setting mode
The odour clear inhibit mode is established by pressing the AUTO button 16-21 seconds (4 beeps sound).
6.
Individual setting mode
The H14 error detection selection mode is established by pressing the auto button about for 21 seconds (5 beeps sound). Now
remove the remote control unit´s battery cover, and short the “SET” terminals to establish the beep sound mute mode.
* If the auto button is pressed and 26 seconds or so are allowed to elapse, the auto button operation mode is restored.
When nothing happens for 60 seconds in the “Setting mode”, “Odour clear setting mode” or “individual setting mode”
or if a remote control code is received, the mode concerned is canceled.
23
CS-ME7CB1P / CS-ME10CB1P / CS-ME12CB1P / CS-ME14CB1P / CS-ME10CD3P / CS-ME14CD3P
Summary of Contents for CS-ME7CB1P
Page 5: ...3 2 INDOOR UNIT 5 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 6: ...6 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 9: ...9 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 10: ...5 2 Grille 10 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 11: ...5 3 Duct Type 11 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 19: ...19 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 60: ...60 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 61: ...61 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...
Page 62: ...62 CS ME7CB1P CS ME10CB1P CS ME12CB1P CS ME14CB1P CS ME10CD3P CS ME14CD3P...