Airflow Direction Auto-Control
•
When set a Airflow Direction Auto-Control with remote
control, the louver swings up and down as shown in the
diagram.
•
The louver does not swing when the Indoor Fan stops
during operation.
•
When stopped with remote control, the discharge vent is
closed with the louver.
Airflow Direction manual Control
•
When the manual Airflow Direction Selection Button is
pressed, the automatic airflow is released and the airflow
direction louver move up and down in the range shown in
the diagram.
The louver can be adjusted by pressing the button to the
desired louver position.
•
When the remote control is used to stop the operation, the
discharge vent is closed with airflow direction louver.
8.10. Airflow Direction Control
1. There is no swinging while indoor fan is stopped during Cooling and Soft Dry operation.
2. In Air Circulation operation, when the intake air temperature reaches set temperature, the airflow direction is changed from upper limit to
lower limit. When the intake air temperature falls to 2°C lower than set temperature, the airflow direction is changed from lower limit to
upper limit.
8.11. Delay ON Timer Control
•
When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
•
For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
•
For Automatic mode, the indoor fan will operate at Lo speed for 20 seconds, 15 minutes before the set time to detect the intake
air temperature to determine the operation mode. The operation indication lamp will blink at this time.
8.12. Remote Control Signal Receiving Sound
•
Long beep sound will be heard when:-
−
Stopping the Air Conditioner using ON/OFF switch.
−
Stopping the Sleep Mode.
−
Stopping the Powerful Mode.
−
Stopping the Economy Mode.
•
Short beep sound will be heard for others.
•
To switch off the beep sound:-
Press the “Automatic Operation Button” continuously for 10 seconds or more (“beep” “beep” will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound.
However, if the “Automatic Operation Button” has been pressed the Automatic cooling operation will be activated.
If you do not require this operation, you may change it by using the remote control.
40