How to use electronic circuit diagram
TIMER TABLE
Test mode
Name
Time
(When test point
Remarks
Short-circuited)
Sleep Mode Waiting
1 hr.
6 sec.
Sleep Mode Operation
8 hrs.
48 sec.
Real Timer
1 hr.
1 min.
10 min.
10 sec.
1 min.
1 sec.
Time Delay Safety Control
2 min. 58 sec.
0 sec.
Forced Operation
60 sec.
0 sec.
Time Save Control (Cooling)
7 min.
42 sec.
Anti-Freezing
4 min.
0 sec.
Soft Dry
OFF
6 min.
36 sec.
ON
10 min.
60 sec.
SOFT DRY : 10 min. operation
Deodorizing Control
40 sec.
4 sec.
Cooling
70 sec.
7 sec.
20 sec.
2 sec.
180 sec.
18 sec.
Soft Dry
40 sec.
4 sec.
360 sec.
36 sec.
Comp. Reverse Rotation Detection
5 min.
30 sec.
Comp. ON 5 min. and above
2 min
0 sec.
Comp./ Fan Motor Delay Timer
1.6 sec.
0 sec.
Intake Air Anti-Freezing Prevention
16 min.
96 sec.
POWERFUL MODE
15 min.
4.5 sec.
Random Auto Restart Control
0 ~ 150 sec.
0 sec.
TRS Recovery Detection
12 min.
72 sec.
6 min.
36 sec.
3 min.
18 sec.
1 min.
6 sec.
Time Save Control (Heating)
30 min.
3 sec.
4 Way Valve Control (Delay)
5 min.
30 sec.
Deice Operation Occurs
60 min.
6 sec.
60 min. after previous deice
Deice Ends
12 min.
72 sec.
95
CS-MA95KE CU-MA185KE / CS-MA125KE CU-MA245KE / CS-MA75KE / CS-MA125KE CU-MA195KE
Summary of Contents for CS-MA95KE
Page 12: ...4 Dimensions 12 CS MA95KE CU MA185KE CS MA125KE CU MA245KE CS MA75KE CS MA125KE CU MA195KE...
Page 13: ...13 CS MA95KE CU MA185KE CS MA125KE CU MA245KE CS MA75KE CS MA125KE CU MA195KE...
Page 15: ...6 Block Diagram 15 CS MA95KE CU MA185KE CS MA125KE CU MA245KE CS MA75KE CS MA125KE CU MA195KE...
Page 81: ...81 CS MA95KE CU MA185KE CS MA125KE CU MA245KE CS MA75KE CS MA125KE CU MA195KE...
Page 82: ...82 CS MA95KE CU MA185KE CS MA125KE CU MA245KE CS MA75KE CS MA125KE CU MA195KE...
Page 83: ...83 CS MA95KE CU MA185KE CS MA125KE CU MA245KE CS MA75KE CS MA125KE CU MA195KE...
Page 94: ...94 CS MA95KE CU MA185KE CS MA125KE CU MA245KE CS MA75KE CS MA125KE CU MA195KE...