– 21 –
MAC9509078C2
CS-MA90KE
Operation Details
Time Delay Safety Control
➡
➡
Compressor Reverse Rotation
Protection Control
➡
➡
4-way Valve Control
Compressor
OFF
Compressor
restarts
(4 minutes waiting)
Compressor
restarts
(4 minutes waiting)
Compressor
OFF
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
1234567890123456789012
Indoor
heat
exchanger
34
30
SLo
Indoor Fan
OFF
Hot Start Control
3) Heating Mode Operation
Heating in operation according to Remote Control setting.
• When the compressor is stopped by Power Switch, Remote Control or there is a power failure, it restarts after 3
minutes when the Power Switch, Remote Control is turned ON or the power supply is resumed.
• When the setting temperature is reached during heating operation, the compressor stops and it will not start for
4 minutes.
• Indoor Fan stops for 1 minute after 3 minutes compressor stops. Then, it will operate with SLo fan speed.
• If the temperature of the indoor heat exchanger rises to 51
°
C, Outdoor Fan stops.
The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49
°
C.
• If the indoor heat exchanger becomes 65
°
C or more, the compressor will stop and restart automatically.
(Time Delay Safety Control – 4 minutes waiting)
• If the compressor is operating continually for 5 minutes or longer and temperature difference between intake air and
indoor heat exchanger is 5
°
C or less for 2 minutes, compressor will stop and restart automatically.
(Time Delay Safety Control is valid).
∆
T = Indoor heat exchanger temperature – intake air temperature
This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
• 4-way valve always ON during Heating operation.
• When the unit is switched to "OFF" during Heating operation, 4-way valve stays at Heating position for 5 minutes.
When Heating operation starts, Indoor Fan will not start until the indoor heat exchanger reaches 30
°
C as diagram
shown.
Hot Start is completed when indoor heat exchanger reaches 41
°
C.
Lo
–
Overload Protection Control
• Compressor starts for 5 minutes
•
∆
T
≤
5
°
C for 2 minutes
Indoor heat exchanger
temperature
≤
65
°
C
(
°
C)
Untitled-5
6/30/00, 7:54 AM
21