background image

6

��������

HOW TO OPERATE

Sleep Timer

■ 

Operation Details

 Ensure the clock on the remote control has been set 

correctly.

 You could use the ON and OFF timers at the same time.

 To cancel either the ON or OFF timer, press 

 or 

, then 

press 

.

•  Enables you to select the pre-set 

timer. It automatically stops after the 

selected scheduled time.

•  When selection is 5 or 7 hours, the 

setting temperature changes after 3 

hours :

Cooling • Dry

↑ 1°C

Heating

↓ 1°C

SLEEP TIMER

Enables sleep 

timer.

SLEEP 

TIMER

•  Use the ON timer to turn on the air 

conditioner at the desired time. This 

will give you a cooling or warming  

environment, e.g. when you return 

from work or wake up.

•  When the ON timer is set, operation 

will start maximum 50 minutes earlier 

before the actual set time.

•  Use the OFF timer to stop the air 

conditioner operation at the desired 

time. This can save electricity while 

you are going out or sleeping.

•  The set timer will repeat daily once it 

is set.

•  If there is a power failure, press the 

SET button to restore the previous 

setting once the power is resumed.

•  If the timer is cancelled, you can 

restore the previous setting by 

pressing the SET button.

•  When used together with the Sleep 

Timer, the Sleep Timer is given priority.

TIMER

1

Select ON or 

OFF timer.

2

Set the 

desired time.

3

Confirm the 

setting.

CANCEL

Cancel the 

selected timer.

  For your convenience, you could set the air conditioner to operate automatically by using both ON and OFF timer.

Hint

Troubleshooting

  TIMER indicator always on.

  Timer is activated and the setting will repeat itself daily.

  POWER indicator is blinking 70 minutes before ON 

timer is activated.

  The unit is determining the operation mode by sensing the indoor/

outdoor temperature. This happens when it has been set to AUTO 

operation mode.

CHECK

•  Where there is error, the unit stops 

its operation and timer indicator 

blinks.

1. Press for 5 seconds.

3. Turn off the power supply and call 

authorized distributor.

4. Press “CHECK” button for 5 seconds/

wait 30 seconds to quit checking.

ERROR RESET

Press the “ERROR RESET” button to 

stop the Timer indicator from blinking.

Unit might be operated with limited 

function depending on error found.

(Operation starts, 4 “beep” sounds are 

heard.)

Timer

2. Browse for respective error code, 

where “beep” sounds are heard.

B1_X_1EN(1-7).indd   6

5/31/2005   9:37:26 AM

Summary of Contents for CS-HE12DKE

Page 1: ...13 44 ITALIANO Prima di utilizzare l unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro 14 19 44 NEDERLANDS Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig na en bewaar ze voor toekomstig gebruik 20 25 44 PORTUGUÊS Antes de ligar a unidade leia cuidadosamente este manual de utilização e guarde o para futura...

Page 2: ...e DBT Dry Bulb Temperature WBT Wet Bulb Temperature Indoor Outdoor DBT WBT DBT WBT Maximum Temperature COOL 32 23 43 26 Maximum Temperature HEAT 30 24 18 Minimum Temperature COOL 16 11 16 11 Minimum Temperature HEAT 16 10 11 Different countries may have different colour coding for the wires Caution Insert the power plug properly Use specified supply cord If the supply cord is damaged or needed to b...

Page 3: ... Error reset Sleep timer LCD display Air inlet rear Air outlet Air inlet side Troubleshooting Mist emerges from indoor unit Condensation effect due to cooling process Remote control display does not work Check whether batteries are correctly inserted or need replacement The unit cannot operate Check either circuit breaker is tripped power plug is inserted correctly or timer is used correctly Ensur...

Page 4: ...ld be activated in all operation modes Press button to stop start the selected operation To save electricity close the curtains when using air conditioner to prevent sunlight and heat from coming in Approximately 10 of electricity can be saved if you set the temperature 1 C higher in cooling operation or 2 C lower in heating operation than the desired temperature Hints Operation Details Opens for ...

Page 5: ...utomatic fan speed The speed of the indoor fan is automatically adjusted according to the operation FAN SPEED AIR SWING To change airflow direction There are 5 selections in addition to automatic vertical airflow direction If automatic vertical airflow direction has been set the louver swings up and down automatically To change airflow direction There are 5 selections in addition to automatic horizont...

Page 6: ... is resumed If the timer is cancelled you can restore the previous setting by pressing the SET button When used together with the Sleep Timer the Sleep Timer is given priority TIMER 1 Select ON or OFF timer 2 Set the desired time 3 Confirm the setting CANCEL Cancel the selected timer For your convenience you could set the air conditioner to operate automatically by using both ON and OFF timer Hint ...

Page 7: ... doors have been closed properly Ensure filters are cleaned or replaced when necessary Ensure inlet and outlet vents of outdoor unit have not been obstructed Troubleshooting Clean the filter regularly as dirty filters will cause unpurified air low cooling or heating capacity unpleasant smells and higher energy consumption The unit will become dirty and the performance of the unit will decrease after u...

Page 8: ...ezondheid en voor het milieu omwille van het niet correct hanteren van afval Het ontmantelen en de afvoer van koelmiddel olie en andere delen moet gebeuren door een gekwalificeerd installateur in overeenstemming met de betrokken plaatselijke en nationale bepalingen Airconditioners moeten in een gespecialiseerd bedrijf worden behandeld voor herbruik recycling en recuperatie en mogen niet in de gemee...

Reviews: