10.2.9.
Four-way Valve Operation Detection Control (Switching Abnormality between
Cooling and Heating)
In Cooling operation
1. When indoor heat exchanger temperature exceeds 45°C in 4 minutes after compressor starts, compressor will be stopped.
2. If the above excess occurs 4 times per 30 minutes, timer LED is to be blinking. (“F11” is to be confirmed.)
In Heating operation
1. When indoor heat exchanger temperature is below 0°C in 4 minutes after compressor starts, compressor will be stopped.
2. If the above excess occurs 4 times per 30 minutes, timer LED is to be blinking. (“F11” is to be confirmed.)
10.2.10. Freeze Prevention Control (Cooling and Soft Dry Operation)
Limit of Cooling power
1. When temperature of indoor heat exchanger is below 5°C, operating frequency will be decreased.
2. When temperature of indoor heat exchanger exceeds 7°C, operating frequency will be increased. (But, up to programmed
frequency.)
3. When temperature of indoor heat exchanger is below 0°C continuously for 6 minutes, compressor will be stopped.
4. Timer LED is not blinking. (“F99” is memorized, then.)
Limit of Indoor fan speed
• When temperature of indoor heat exchanger is below 6°C (2°C at Soft Dry) continuously for 6 minutes, indoor fan speed will be
increased by 50 rpm.
10.2.11. Outdoor Air Temperature Control
The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the diagram below.
This control will begin one minute after the compressor starts.
10.2.12. Indoor Intake Air Temperature Control (Heating operation)
1. When indoor air temperature is 35°C or more, the maximum power will be limited up to the rated power.
2. When fan speed is set at “Lo” and intake air temperature is below 21°C, the maximum power will be limited up to the rated-
power.
Summary of Contents for CS-E9EKK
Page 9: ...9 4 Dimensions 4 1 Indoor Unit ...
Page 10: ...10 4 2 Outdoor Unit ...
Page 11: ...11 5 Refrigeration Cycle Diagram ...
Page 12: ...12 6 Block Diagram ...
Page 13: ...13 7 Wiring Connection Diagram ...
Page 14: ...14 ...
Page 15: ...15 8 Printed Circuit Board 8 1 Indoor Unit Main Printed Circuit Board ...
Page 16: ...16 8 2 Outdoor Unit Main Printed Circuit Board ...
Page 17: ...17 8 3 Indicator panel ...
Page 20: ...20 This can be used for left rear piping and left bottom piping also ...
Page 37: ...37 14 Technical Data 14 1 Thermostat Characteristics ...
Page 38: ...38 14 2 Operation Characteristics Cooling Characteristic at Different Outdoor Air Temperature ...
Page 39: ...39 ...
Page 40: ...40 ...
Page 41: ...41 ...
Page 42: ...42 ...
Page 43: ...43 ...
Page 44: ...44 ...
Page 45: ...45 ...